SUBMITTAL DATA SHEET
One Way Cassette Heat Pump System
Project Information
Location: | |
Engineer: | |
Submitted to: | |
Submitted by: | |
Reference: | |
Approval: | |
Date: | |
Construction: | |
Unit #: | |
Drawing #: |
[AHRI Certified Logo]
[ENERGY STAR Logo]
[ETL Listed Logo]
Efficiency
Cooling | Heating | |
---|---|---|
SEER2 | 22.0 | HSPF2-4 12.0 |
EER2 | 15 | COP 3.75 |
Performance of Cooling
Cooling (Btu/hr) | |
---|---|
Rated Capacity | 6500 |
Min/Max Capacity | 3600~11200 |
Moisture Removal (L/h) | 0.34 |
Standard Operating Range (°F/°C) | -22~122 (-30~50) |
Conditions: | Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB |
Performance of Heating
Heating (Btu/hr) | |
---|---|
1. @ 47°F Rated | 7400 |
1. @ 47°F Min/Max Capacity | 3700~11500 |
2. @ 17°F Rated | 7000 |
3. @ 5°F Rated: Capacity / COP | 8100/2.40 |
3. @ 5°F Max: Capacity | 8100 |
Standard Operating Range (°F/°C) | -22~75 (-30~24) |
1. Conditions: | Indoor: 70°F DB/60°F WB Outdoor: 47°F DB/43°F WB |
2. Conditions: | Indoor: 70°F DB/60°F WB Outdoor: 17°F DB/15°F WB |
3. Conditions | Indoor: 70°F DB/60°F WB Outdoor: 5°F DB/5°F WB |
Indoor Unit Specifications
Value | |
---|---|
Indoor Air Flow (Turbo/H/M/L/Si) (CFM) | 341.4 / 294.3 / 259.0 / 235.4 / N/A |
Indoor Noise Level (Turbo/H/M/L/Si) (dBA) | 46.5/37.5/35.5/26/23.5 |
Dimension (W×D×H) | inch: 50.31 x 13.19 x 8.98 |
mm: 1278.0×335.0×228.0 | |
Package (W×D×H) | inch: 57.60 x 22.48 x 22.64 |
mm: 1463×571×575 | |
Net/Gross Weight | lbs: 45.19/82.45 |
kg: 20.5/37.4 |
Outdoor Unit Specifications
Value | |
---|---|
Compressor Type | ROTARY |
Compressor Model | KSK103D33UEZ3 |
Refrigerant | R454B |
Refrigerant Oil Charge (mL) | 310 |
Refrigerant Oil | VG74 |
Outdoor Air Flow (Max) (CFM) | 1236.1 |
Outdoor Noise Level (dBA) | 53.5 |
Dimension (W×D×H) | inch: 30.12 x 11.93 x 21.85 |
mm: 765.0×303.0×555.0 | |
Package (W×D×H) | inch: 34.92 x 13.27 x 24.02 |
mm: 887×337×610 | |
Net/Gross Weight | lbs: 62.17/67.68 |
kg: 28.2/30.7 |
Electrical Specifications
Value | |
---|---|
Power Supply | 208/230V, 60Hz, 1Ph |
System MCA | 12.00 |
Connection Wiring | 14#x4 |
System MOCP | 15 |
Compressor RLA | 7.3 |
Outdoor Fan Motor RLA | 0.6 |
Outdoor Fan Motor W | 34 |
Indoor Fan Motor RLA | 0.8 |
Indoor Fan Motor W | 30 |
System Power Input @ Cooling (W) | 427 (155 ~ 680) |
System Power Input @ Heating (W) | 578 (290 ~ 950) |
Piping Specifications
Value | |
---|---|
Throttle type (Indoor) | N/A |
Throttle type (Outdoor) | EXV |
Liquid Size | 6.35mm (1/4in) |
Gas Size | 9.52mm (3/8in) |
Max. Piping Length (ft/m) | 82.02 (25) |
Max. Height Difference (ft/m) | 49.21 (15) |
Max. Pre-charged Length (ft/m) | 24.6 (7.5) |
Refrigerant Pre-charged Amount (oz/kg) | 32.45 (0.92) |
Additional Charge of Refrigerant ((oz/ft)/(g/m)) | 0.16 (15) |
Connection Method | Flared |
Indoor Unit Dimensions
Diagrams illustrating the dimensions of the indoor unit. Multiple views (top, front, side) are provided with measurements in inches and millimeters. Key dimensions include width, depth, and height.
Indoor Unit Installation Instructions
Diagrams showing installation clearances for the indoor unit. Perspective A illustrates roof mounting, indicating minimum distances from the ceiling and walls. Perspective B shows ground mounting, detailing clearances around air inlet and outlet. Measurements are provided in inches and millimeters.
Outdoor Unit Dimensions
Diagrams showing the dimensions of the outdoor unit from front, side, and top views. Measurements are provided in inches and millimeters. Includes overall width, depth, and height, as well as detail views of connection points.
Outdoor Unit Installation Instructions
Diagram illustrating required clearances around the outdoor unit for proper ventilation. Arrows indicate minimum distances (e.g., 20 inches, 4 inches, 14 inches) required from the front, sides, and rear of the unit, depending on surrounding obstructions. A checkmark icon [✔️] indicates that all spatial requirements must be met.
Features
- Designed to fit between both I-joist spacing and traditional joist spacing
- Elevation panel
- Refrigerant leakage detection sensor (Optional)
- Humidity sensor
- Built-in pump
- Built-in circuit breaker
- 1%~100% fan speed setting
- WiFi capability: through WiFi dongle or wired controller with built-in WiFi
- OTA (by using WiFi dongle)
- 2-pin connector (HA/HB) for programmable wired controller
- Multiple control options available:
- Two way communication wired controller: 120N(X6)
- Two way communication wired controller with built-in WiFi: 120N(X6W)
- Infrared wired controller: 120L
- Wireless remote controller
- Third-Party 24V Thermostat*
*24V interface is required.