Blue Ridge XS5 CDH High Static Slim Duct Hyper Heat Series Submittal Data Sheet
General Information
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Approval:
Date:
Construction:
Unit #:
Drawing #:
Efficiency Ratings
Rating | Cooling | Heating |
---|---|---|
SEER2 | 18.4 | HSPF2-4 11.1 |
EER2 | 12 | COP 3.60 |
Performance of Cooling
Rated Capacity | 17500 Btu/hr |
Min/Max Capacity | 4000~20600 Btu/hr |
Moisture Removal (L/h) | 1.39 |
Standard Operating Range (°F/°C) | -22~122 (-30~50) |
Conditions | Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB |
Performance of Heating
1. @ 47°F Rated | 19500 Btu/hr |
1. @ 47°F Min/Max Capacity | 5400~23000 Btu/hr |
2. @ 17°F Rated | 15000 Btu/hr |
3. @ 5°F Rated: Capacity / COP | 18000 Btu/hr / 2.10 |
3. @ 5°F Max: Capacity | 18000 Btu/hr |
Standard Operating Range (°F/°C) | -22~75 (-30~24) |
Conditions | 1. Indoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB 2. Indoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB 3. Indoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB |
Indoor Specifications
Indoor Air Flow (Turbo/H/M/L/Si) (CFM) | 706.3 / 618.0 / 529.7 / 441.4 / N/A |
Indoor Noise Level (Turbo/H/M/L/Si) (dBA) | N/A / 36 / 34.0 / 32.0 / 28.0 |
Indoor Static Pressure Range (in.w.g.) | 0-0.8 |
Dimension (W×D×H) | inch: 39.37 x 29.53 x 9.65 |
mm: 1000.0×750.0×245.0 | |
Package Dimension (W×D×H) | inch: 48.23 x 33.86 x 11.97 |
mm: 1225×860×304 | |
Net/Gross Weight | lbs: 79.81/91.27 kg: 36.2/41.4 |
Outdoor Specifications
Compressor Type | ROTARY |
Compressor Model | KTM240D46UKT2 |
Refrigerant | R454B |
Refrigerant Oil Charge (mL) | 620 |
Refrigerant Oil | 4.15/9.30 |
Outdoor Air Flow (Max) (CFM) | 1765.8 |
Outdoor Noise Level (dBA) | 57.5 |
Dimension (W×D×H) | inch: 35.04 x 13.46 x 26.50 |
mm: 890.0×342.0×673.0 | |
Package Dimension (W×D×H) | inch: 39.17 x 15.67 x 29.13 |
mm: 995×398×740 | |
Net/Gross Weight | lbs: 99.87/107.80 kg: 45.3/48.9 |
Electrical Specifications
Power Supply | 208/230V, 60Hz, 1Ph |
System MCA | 19.00 A |
Connection Wiring | 14#x4 |
System MOCP | 20 A |
Compressor RLA | 11.7 A |
Outdoor Fan Motor RLA | 0.9 A |
Outdoor Fan Motor W | 80 W |
Indoor Fan Motor RLA | 1.8 A |
Indoor Fan Motor W | 165 W |
System Power Input @ Cooling (W) | 1446 (350 ~ 1790) W |
System Power Input @ Heating (W) | 1590 (340 ~ 1750) W |
MCA: Min. circuit amps (A) | |
MOCP: Max. over current protection (A) | |
RLA: Rated load amps (A) | |
W: Fan motor rated output (W) |
Piping Specifications
Throttle type (Indoor) | N/A |
Throttle type (Outdoor) | EXV + Throttle valve |
Liquid Size | 6.35mm (1/4in) |
Gas Size | 12.7mm (1/2in) |
Max. Piping Length (ft/m) | 98.40 ft (30 m) |
Max. Height Difference (ft/m) | 65.60 ft (20 m) |
Max. Pre-charged Length (ft/m) | 24.6 ft (7.5 m) |
Refrigerant Pre-charged Amount (oz/kg) | 55.38 oz (1.57 kg) |
Additional Charge of Refrigerant ((oz/ft)/(g/m)) | 0.16 oz/ft (15 g/m) |
Connection Method | Flared |
Indoor Unit Dimensions and Installation
Indoor Unit Diagram Description: The diagram illustrates the indoor unit, highlighting the electric control box, top and bottom sections, hanging brackets, drain pipe connection, and liquid/gas side connections.
MODEL | A | B | C | D |
---|---|---|---|---|
9K | 27-1/2in (700mm) | 7-7/8in (200mm) | 17-3/4in (450mm) | 20in (506mm) |
12K | 27-1/2in (700mm) | 9-5/8in (245mm) | 29-1/2in (750mm) | 31-1/4in (795mm) |
18K~24K | 39-3/8in (1000mm) | 9-5/8in (245mm) | 29-1/2in (750mm) | 31-1/4in (795mm) |
36K~48K | 47-1/8in (1200mm) | 11-7/8in (300mm) | 29-1/2in (750mm) | 31-1/4in (795mm) |
60K | 55-1/8in (1400mm) | 15in (380mm) | 31-1/2in (800mm) | 33-1/4in (845mm) |
Installation Instructions - Indoor Unit Clearances:
- Ceiling-mounted: Requires specific clearances from the left side (minimum 90.6in / 230cm), right side (minimum 7.9in / 20cm), and below (minimum 15.7in / 40cm). Service access is also indicated.
- Wall-mounted: Requires minimum clearances from the floor (minimum 0.8in / 2cm), left side (minimum 11.8in / 30cm), right side (minimum 0.8in / 2cm), and front (minimum 23.6in / 60cm).
Outdoor Unit Dimensions and Installation
Outdoor Unit Diagram Description: Diagrams show the outdoor unit from side, front, and top views, with detailed dimensions labeled (W, W1, W2, W3, D, D1, D3, H, H1, H2) in inches and millimeters.
Installation Instructions - Outdoor Unit Clearances:
- Clearances are specified for optimal airflow and service access.
- Minimum 20 inches (500mm) clearance is required in front and on sides when the unit is clear.
- Minimum 4 inches (100mm) clearance is required on sides when the unit is clear.
- Minimum 14 inches (350mm) clearance is required on the rear when the unit is clear.
- A checkmark [✔️] indicates that all spatial requirements shown in the installation clearance requirements are met.
Fan Performance
These charts illustrate the fan performance of the Slim Duct Heat Pump System, showing the relationship between air volume (CFM) and external static pressure (in.WC) for various fan speed settings (SH, H, M, L). Eight charts (SP1 through SP8) are provided, each detailing performance across different static pressure ranges. An additional chart displays constant air volume performance.
Features
- Compatible with both horizontal and vertical installation.
- Static pressure up to 0.8 in.w.g. (for all models).
- Static pressure setting stages: 8.
- Refrigerant leakage detection sensor.
- Constant airflow.
- Built-in pump.
- i-clean function.
- Fan speed stages: 1~100%.
- WiFi capability: through wired controller with built-in WiFi.
- OTA updates: via wired controller 120N(X6W).
- 2-pin connector (HA/HB) for programmable wired controller.
- Multiple control options available:
- Two-way communication wired controller: 120N(X6).
- Two-way communication wired controller with built-in WiFi: 120N(X6W).
- Infrared wired controller: 120L.
- Wireless remote controller.
- Third-Party 24V Thermostat* (*24V interface is required).