JABLOTRON JA-110A Indoor Bus Siren
Introduction
This document was translated from English. For any uncertainty or doubt, please read the original version of the document. If you encounter any errors or have further questions, please contact technical support (contact details are at the end of the document).
The product is part of the JABLOTRON system. It is intended for indoor alarm signaling. Pressing the button on the siren can silence an ongoing alarm (= confirming the presence of a person in the building). The siren must be installed by a trained professional holding a valid certificate issued by an authorized distributor.
Installation
Always connect the bus cable when the system power is completely switched off.
- Remove the siren housing (1) from the plastic frame by pressing the side of the housing with a screwdriver, as shown in Figure 1.
- Remove the central part of the frame (3) by pressing the 4 tabs (2) indicated by arrows.
- Pass the bus cable through the rectangular recess designated for this purpose on the plastic base.
- Fix the plastic base to the chosen location using screws.
- Reassemble the plastic frame with the plastic base onto the lower part.
- Connect the bus cable to the terminals (6) as shown in Figure 2, then place the housing back into the plastic frame.
Note: The anti-tamper switches (7) must be positioned above the magnets in the plastic base.
Figure 1: Siren Removal Before Installation
Figure 2: Description of Siren Interior
Diagram Description: The diagram shows the siren components. Figure 1 illustrates how to detach the siren housing. Figure 2 details the internal connections and parts: 1 - electronic latches; 2 - internal buttons; 3 - serial number; 4 - housing contacts; 5 - piezoelectric siren; 6 - bus connectors; 7 - anti-tamper switch.
Registration and Settings
Depending on the control panel type, use the recommended software or application; refer to the control panel manual.
Technical Specifications
Parameter | Value |
---|---|
Power Supply | From the bus 12 V DC (9...15 V) |
Quiescent Current Consumption | 5 mA |
Maximum Current Consumption | 30 mA |
Siren | Piezoelectric, 85 dB/m |
Type of Warning Device | Indoor, Type X |
Dimensions | 80 x 80 x 28 mm |
Acoustic Performance | 80 dB / 1 meter |
Classification | Security Grade 2 / Environmental Class II (according to EN 50131-1 standard) |
Environment | Indoor general |
Weight | 70 grams |
Operating Temperature Range | -10 °C to +40 °C |
Average Operating Humidity | 75% relative humidity, non-condensing |
Certifying Body | Trezor Test sro (No. 3025) |
Complies with | EN 50131-1, -4, EN 50130-4, EN 55032, EN IEC 62368-1, EN IEC 63000 |
Can be operated according to | ERC REC 70-03 |
Recommended Screw | 2x 3.5 x 40 mm (countersunk head) |
Declarations and Disposal
[UKCA Mark] [CE Mark]
JABLOTRON a.s. hereby declares that the JA-110A device, when used as intended, complies with the relevant European Union harmonization legislation: Directives 2014/30/EU, 2014/35/EU, and 2011/65/EU. The original copy of the conformity assessment can be found on the www.jablotron.com website in the Downloads section.
Note on Disposal: Proper disposal of this product helps conserve valuable resources and prevents potential negative impacts on human health and the environment that could otherwise result from improper waste management. Please return the product to your retailer or contact your local municipality regarding the nearest designated collection point.
For the electronic version of this document (available in other languages) or for installation into a JA-100+ system, scan the QR code provided. [QR Code Placeholder]
Document translated from EN origin (MLP21817) on 2025-07-25.