R. STAHL Isolator Barriers

Loop-powered binary output

Ex i field circuit

9276/10-24-48-00k Art. No. 261446

Key Features

Series 9276 digital outputs issue signals for the intrinsically safe operation of Ex i solenoid valves, indicator lamps or horns. The devices do not require a separate auxiliary power supply as they are powered by the control circuit. The intrinsically safe outputs are galvanically separated from the inputs.

Certifications: ATEX (IBE), Canada (UL), China (CQM), IECEx (IBE), SIL (exida), USA (UL), DNV, ATEX (EUK), China (CCC)

Technical Data

Explosion Protection

Application range (zones) 2
Ex interface zone 0, 1, 2, 20, 21, 22
IECEX gas certificate IECEx IBE 17.0045X
IECEx gas explosion protection Ex ec [ia Ga] IIC T4 Gc
IECEx dust certificate IECEx IBE 17.0045X
IECEx dust explosion protection [Ex ia Da] IIIC
IECEX firedamp certificate IECEx IBE 17.0045X
IECEx firedamp protection [Ex ia Ma] I
ATEX gas certificate IBEXU 17 ATEX 1153 X
ATEX gas explosion protection II 3 (1) G Ex ec [ia Ga] IIC T4 Gc
ATEX dust certificate IBEXU 17 ATEX 1153 X
ATEX dust explosion protection II (1) D [Ex ia Da] IIIC
ATEX firedamp certificate IBEXU 17 ATEX 1153 X
ATEX firedamp protection I (M1) [Ex ia Ma] I
cULus certificate E81680
Marking cULus Class I, Div. 2, Groups A,B,C,D; Class I, Zone 2, AEx/Ex nA Group IIC; AIS Class I,II,III, Div. 1, Groups A,B,C,D,E,F,G; Class I, Zone 0, [AEx ia]/[Ex ia] IIC; T4 any mounting pos. Ta = 60°C

Safety Data

Max. power P₀ 697 mW
Max. permissible external capacitance C/C for IIC 0.085 μF
Max. permissible external inductance L/La for IIC 4 mH
Max. permissible external capacitance C/C for IIB 0.663 µF
Max. permissible external inductance L/La for IIB 17 mH
Max. permissible external capa.IIA 2.2 μF
Max. permissible external inductance L₀ for IIA 35 mH
Max. perm. ext. capacit. IIIC 0.663 µF
Max. permis. ext. induct. IIIC 17 mH
Max. permissible ext. capac. I 2.2 μF
Max. permissible external inductance L₀ for I 35 mH
Internal capacitance Negligible
Internal inductance Negligible
Safety-related max. voltage 253 V AC

Intrinsically safe limiting values inductance L/capacitance C₀

20 mH 10 mH 5 mH 1 mH 0.100 mH
IIC C₀ [µF] 0.068 μF 0.068 μF 0.068 μF 0.079 μF 0.108 μF
IIB L₀ [mH] 10 mH 5 mH 1 mH 0.100 mH
C₀ [µF] 0.250 μF 0.250 μF 0.350 μF 0.663 µF
IIA L₀ [mH] 20 mH 5 mH 1 mH 0.100 mH
C₀ [µF] 0.440 μF 0.440 μF 0.680 μF 0.960 μF
IIIC L₀ [mH] 10 mH 5 mH 1 mH 0.100 mH
C₀ [µF] 0.250 μF 0.250 μF 0.350 μF
I L₀ [mH] 20 mH 5 mH 1 mH 0.100 mH
C₀ [µF] 0.440 μF 0.440 μF 0.680 μF 0.960 μF

Functional Safety

SIL 3
HFT 0
SFF 100%
Lambda SD 0 FIT
Lambda SU 50 FIT
Lambda DD 0 FIT
Lambda DU 0 FIT

Electrical Data

Number of channels 1
Auxiliary power without
Max. power dissipation 1.41 W
Polarity reversal protection Yes

Galvanic Isolation

Test voltage as per standard EN IEC 60079-11
Galvanic separation Ex i output to input 375 V AC peak value

Input

Input voltage for ON 15 – 30 V
Input voltage for OFF 0 – 5 V

Output

Output open-circuit voltage U₂ 24 V
Max. output current Iₐ max 48 mA
Output internal resistance Rᵢ 275.5 Ω
Switching delay ON/OFF ≤ 20 ms
Switching delay OFF/ON ≤ 20 ms
Response time output 20 ms
Switching state indication Yellow "STAT" LED

Ambient Conditions

Ambient temperature °C -40 °C ... 60 °C
Ambient temperature °F -40 °F ... +140 °F
Storage temperature °C -40 °C ... 80 °C
Storage temperature °F -40 °F ... +176 °F
Max. relative humidity 10 to 95%
Use at the height of < 2000 m
Electromagnetic compatibility EN 61326-1 Use in industrial environment; Immunity according to EN 61000-6-2; Interference emission to EN 61000-6-4

Mechanical Data

Degree of protection (IP) IP30
Degree of protection (IP) terminals IP20
Fire resistance (UL 94) V0
Enclosure material Polyamide
Grid dimension 12.5 mm
Width 12.5 mm
Width, inches 0.49 in
Height 114.5 mm
Height in inches 4.51 in
Length 116 mm
Length in inches 4.57 in
Weight 165 g
Weight 0.36 lb

Mounting / Installation

Mounting type DIN rail NS35/15, NS35/7.5
Mounting orientation Vertical / Horizontal
Connection type Spring clamp terminal
Min. rigid conductor cross section 0.2 mm²
Max. rigid conductor cross section 1.5 mm²
Min. flex conductor cross section 0.2 mm²
Max. flex conductor cross section 1.5 mm²
Connection cross-section AWG 24 ... 16

Technical Drawings

Hazardous Location

Diagram showing input and output connections for hazardous and non-hazardous locations.

Output characteristic curve

A graph illustrating the output characteristic curve of the 9276/10-24-48-00 device, plotting output current (mA) against output voltage (V).

Connection diagram

Diagram showing the connection of the 9276/10 device.

Dimensional Drawings

Diagrams showing the dimensions of the Isolator Barrier, including width, height, and length in both millimeters and inches. It also shows the mounting type for the ISpac Series 9260, 9270, 9275, 9276 with spring clamp terminal.

PDF preview unavailable. Download the PDF instead.

ex-single-data-sheet-loop-powered-binary-output-ex-i-field-circuit-9276-10-24-48-00k-261446-en-us-rstahl Adobe PDF Library 17.0

Related Documents

Preview R. STAHL 9276A Loop-Powered Binary Output Ex i Field Circuit - Technical Data
Technical specifications and safety data for the R. STAHL 9276A loop-powered binary output for Ex i field circuits. Details include explosion protection, electrical data, safety parameters, environmental conditions, and mechanical dimensions.
Preview R. STAHL 9276A Galvanic Isolator: Technical Specifications and Safety Information
Detailed technical specifications, safety features, and installation guidelines for the R. STAHL 9276A galvanic isolator, a loop-powered binary output for Ex i field circuits. Covers explosion protection, electrical characteristics, environmental conditions, and mechanical data.
Preview R. STAHL 9276A Loop-Powered Binary Output Ex i Field Circuit Isolator Barrier
Technical data sheet for the R. STAHL 9276A loop-powered binary output isolator barrier, designed for Ex i field circuits. Features include space-saving slim design, suitability for SIL 3, and intrinsic safety for solenoid valves, indicator lamps, and horns.
Preview R. STAHL 9276/10-24-48-00s Loop-Powered Binary Output Isolator - Technical Data
Detailed technical specifications for the R. STAHL 9276/10-24-48-00s loop-powered binary output isolator, including explosion protection, safety data, electrical characteristics, and mechanical dimensions. Suitable for intrinsically safe operation of Ex i solenoid valves.
Preview R. STAHL 9276/10-24-48-00s Isolator Barrier for Ex i Field Circuits
Technical data sheet for the R. STAHL 9276/10-24-48-00s loop-powered binary output isolator barrier, designed for Ex i field circuits. Features include SIL 3 capability, slim design, and comprehensive explosion protection certifications.
Preview R. STAHL 9276 Series Isolators: Loop-Powered Binary Output for Ex i Field Circuits
Technical data sheet for R. STAHL Series 9276 isolators, featuring loop-powered binary output for Ex i field circuits. Details explosion protection, safety data, electrical specifications, mechanical data, and mounting information.
Preview R. STAHL 9276A Loop-Powered Binary Output Ex i Field Circuit - Technical Data
Technical specifications and data for the R. STAHL 9276A loop-powered binary output for Ex i field circuits. Details include explosion protection, safety data, electrical specifications, environmental conditions, and mechanical data.
Preview R. STAHL Series 9276 Loop-Powered Binary Output Isolator - Technical Data
Detailed technical specifications for the R. STAHL Series 9276 loop-powered binary output isolator (Ex i field circuit), including explosion protection, safety data, electrical data, ambient conditions, and mechanical dimensions.