R. STAHL 9276A Loop-Powered Binary Output Ex i Field Circuit
Article No. 261445
Product Overview
The R. STAHL 9276A is a loop-powered binary output for Ex i field circuits. It emits signals for the operation of intrinsic safety elements such as Ex i solenoid valves, pilot lights, or horns. The devices do not require separate auxiliary power as they are supplied via the control circuit. Intrinsic safety outputs are galvanically isolated from the inputs.
Key Features:
- Extensive catalog for a wide range of solenoid valves
- Space-saving design with a small construction size: 12.5 mm width
- Usable up to SIL 3 (IEC/EN 61508)
Technical Data
Explosion Protection
Applications (zones) | 2 |
Ex zone interface | 0, 1, 2, 20, 21, 22 |
IECEX gas homologation | IECEx IBE 17.0045X |
IECEx gas explosion protection | Ex ec [ia Ga] IIC T4 Gc |
IECEx dust homologation | IECEx IBE 17.0045X |
IECEx dust explosion protection | [Ex ia Da] IIIC |
IECEx firedamp homologation | IECEx IBE 17.0045X |
IECEx firedamp explosion protection | [Ex ia] I |
ATEX gas homologation | IBEXU 17 ATEX 1153 X |
ATEX gas explosion protection | II 3 (1) G Ex ec [ia Ga] IIC T4 Gc |
ATEX dust homologation | IBEXU 17 ATEX 1153 X |
ATEX dust explosion protection | II (1) D [Ex ia Da] IIIC |
ATEX firedamp homologation | IBEXU 17 ATEX 1153 X |
ATEX firedamp explosion protection | I (M1) [Ex ia] I |
cULus homologation | E81680 |
cULus identification | Class I, Div. 2, Groups A,B,C,D; Class I, Zone 2, AEx/Ex nA Group IIC AIS Class I,II,III, Div. 1, Groups A,B,C,D,E,F,G; Class I, Zone 0, [AEx ia]/[Ex ia] IIC T4 any mounting pos. Ta = 60°C See Doc. 9276 6 031 001 3 |
Certifications
Marine certification | ATEX (IBE), Canada (CSA), China (CQM), USA (UL), IECEx (IBE), SIL (exida) |
Certificate of conformity | ATEX (EUK), China (CCC) |
Safety Data
Maximum voltage U | 25.1 V |
Maximum current I (Ex ia) | 87 mA |
Maximum power P | 550 mW |
Maximum external capacitance C for IIC | 0.108 µF |
Maximum external inductance L for IIC | 5 mH |
Maximum external capacitance C for IIB | 0.83 µF |
Maximum external inductance L for IIB | 20 mH |
Maximum external capacitance IIA | 2.93 µF |
Maximum external inductance IIA | 45 mH |
Max. ext. capacitance IIIC | 0.83 µF |
Max. ext. inductance IIIC | 20 mH |
Max. ext. capacitance I | 2.93 µF |
Maximum external inductance L for I | 45 mH |
Internal capacitance | Irrelevant |
Internal inductance | Irrelevant |
Maximum technical safety voltage | 253 V AC |
Intrinsic Safety Limits (Inductance L / Capacitance C)
2 mH | 1 mH | 0.500 mH | 0.200 mH | 0.100 mH | |
---|---|---|---|---|---|
IIC L [mH] | 2 | 1 | 0.500 | 0.200 | 0.100 |
IIC C [µF] | 0.052 | 0.065 | 0.082 | 0.108 | 0.108 |
IIB L [mH] | 10 | 5 | 1 | 0.100 | |
IIB C [µF] | 0.380 | 0.380 | 0.440 | 0.820 | |
IIA L [mH] | 20 | 5 | 1 | 0.100 | |
IIA C [µF] | 0.600 | 0.610 | 0.640 | 1 | |
IIIC L [mH] | 10 | 5 | 1 | 0.100 | |
IIIC C [µF] | 0.380 | 0.380 | 0.440 | 0.820 | |
I L [mH] | 20 | 5 | 1 | 0.100 | |
I C [µF] | 0.600 | 0.610 | 0.640 | 1 |
Functional Safety
SIL | 3 |
HFT | 0 |
SFF | 100% |
Lambda SD | 0 FIT |
Lambda SU | 50 FIT |
Lambda DD | 0 FIT |
Lambda DU | 0 FIT |
Electrical Data
Number of channels | 1 |
Auxiliary Power
Auxiliary power | None |
Auxiliary Power
Maximum dissipated power | 1.06 W |
Reverse polarity protection | Yes ✔️ |
Galvanic Separation
Test voltage according to standard | EN IEC 60079-11 |
Galvanic separation Ex i output to input | 375 V AC maximum value |
Input
Input voltage for ON | 15 - 30 V |
Input voltage for OFF | 0 - 5 V |
Output
Output open-circuit voltage U₂ | 21.9 V |
Maximum output current Iₐ max | 40 mA |
Output internal resistance R | 287 Ω |
Switching delay ON/OFF | ≤ 20 ms |
Switching delay OFF/ON | ≤ 20 ms |
Output stabilization time | 20 ms |
Switching status indication | Yellow LED "STAT" |
Environmental Conditions
Ambient temperature | -40 °C ... 60 °C (-40 °F ... +140 °F) |
Storage temperature | -40 °C ... 80 °C (-40 °F ... +176 °F) |
Maximum relative humidity | 10 ... 95% |
Altitude of use | < 2000 m |
Electromagnetic compatibility | EN 61326-1 industrial use Immunity according to EN 61000-6-2 Radiated spurious emissions according to EN 61000-6-4 |
Mechanical Data
Degree of protection (IP) | IP30 |
Degree of protection (IP) terminals | IP20 |
Fire resistance (UL 94) | V0 |
Enclosure material | Polyamide |
Grid dimension | 12.5 mm |
Width | 12.5 mm |
Mounting width in inches | 0.49 in |
Height | 114.5 mm |
Height in inches | 4.51 in |
Length | 116 mm |
Length in inches | 4.57 in |
Weight | 165 g (0.36 lb) |
Mounting / Installation
Mounting position | Vertical / Horizontal |
Connection type | Spring terminal |
Minimum rigid conductor cross-section | 0.2 mm² |
Maximum flexible conductor cross-section | 1.5 mm² |
Minimum flexible conductor cross-section | 0.2 mm² |
Maximum flexible conductor cross-section | 1.5 mm² |
Ambient temperature AWG | 24 ... 16 |
Dimensional Drawing (all dimensions in inches)
A schematic drawing shows the device dimensions: Height 114.5 mm [4.51 in], Length 116 mm [4.57 in], Width 12.50 mm [0.49 in]. It also indicates compatibility with Ipac series 9260, 9270, 9275, 9276, 9282 with spring terminal.
R. STAHL reserves the right to modify technical data, dimensions, weights, designs, and delivery options.
Contact Information:
R. STAHL Schaltgeräte GmbH
Am Bahnhof 30
74638 WALDENBURG
Tel. +49 7942 943 1700 | +49 7942 943 1777
Email: sales.de@r-stahl.com