Jablotron JA-151M Wireless Magnetic Door Detector - Mini

The JA-151M is a component of the JABLOTRON JA-100 system. It is used to detect the opening of doors, windows, etc. The miniature battery-powered detector has an optional reaction (pulse or status). The detector should be installed by a trained technician with a valid certificate issued by an authorized distributor.

Installation

Choose a suitable place for the detector's installation. The detector reacts to the removal of its permanent magnet. The magnet can be installed on the left or on the right side of the detector. The electronics should be installed onto the non-moving part of windows or doors and the magnet onto the moving part. Avoid installing it directly on a metal frame as metal influences the functioning of the magnetic sensor and radio communication.

Figure 1: Cover tab and red activation indicator

1. Open the detector cover by pushing the tab (1).

2. Screw the rear cover to the solid part of the door (window).

3. Attach the permanent magnet to the moving part of the door (window) with screws. The distance between the electronic part and the magnet should be as small as possible. The distances between the magnet and the sensor which activate the detector are shown in the following figure.

Diagram showing the placement of the detector and magnet on a door/window. The detector unit is labeled 'II' and the magnet unit is labeled 'I'. Arrows indicate the relative positioning for activation.

4. Enroll the detector to a control panel (receiver). There must be a JA-11xR radio module present in the system for the detector to be enrolled. Go to the F-Link program, select the required position in the Devices window and launch enrollment mode by clicking on the Enroll option. The enrollment signal is transmitted as soon as the battery is inserted into the detector.

5. When the detector has been enrolled, insert it into the base.

6. Use the F-Link program to set the detector's functions.

7. Test the detector's correct functioning.

Diagram showing the components of the detector and magnet. Components are numbered: 3 - production code, 4 - tamper contact, 5 - battery, 6 - permanent magnet, 7 - magnetic sensor, 8 - red detector activation indicator, 9 - alternative location of the permanent magnet.

Note: If you want to enroll a detector which has already been connected to a battery, first disconnect the battery, then press and release the tamper contact in the cover (4) in order to release the remaining charge and then you can proceed with the enrollment.

Setting the detector properties

The detector has two function modes which are indicated with either one or two flashes of the LED indicator when the battery is inserted.

The function modes can be set by holding the tamper contact in the detector cover, inserting the battery and releasing the tamper contact after 3-5 seconds. The detector then flashes either once or twice to indicate the currently selected mode.

Other functions can be set in the Devices window in the F-Link program. Here you can set the type of reaction of the system to the activation of the enrolled detector, section to which the detector should be enrolled and also a PG output which can be controlled by the detector. The default setting is a Basic reaction (Delayed A = provides entrance and exit delay).

Detector testing

When you close the detector cover, a detector testing mode is triggered for 15 minutes and each activation is indicated by the LED indicator on the detector cover. The detector signal and its activation can be monitored in the control panel service mode in the Diagnostics window in the F-Link program.

Battery replacement

The detector monitors its battery voltage and if it is low, a report is sent to the control panel to inform the user. The detector continues to function. Battery replacement should be done by a qualified technician with the control panel in Service mode within 14 days of the report. Test the correct function of the detector after each battery replacement.

Technical specifications

Voltage: Lithium battery, type CR2032 (3.0V, 220 mAh)

Typical battery lifetime: cca 2 years (max. 20 activations daily)

Communication band: 868.1 MHz, protocol JABLOTRON

Communication range: approx. 100m (open area)

Dimensions: transmitter part 55 x 26 x 16 mm, magnet part 55 x 16 x 16 mm

Operational environment according to EN 50131-1: II. Indoor general, grade 2

Operational temperature range: -10°C to +40 °C

Classification: according to EN 50131-1, EN 50131-2-6, EN 50131-5-3

Complies with: ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1

Can be operated according to: ERC REC 70-03

JABLOTRON ALARMS a.s. hereby declares that the JA-151M is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The original of the conformity assessment can be found at www.jablotron.com, Technical Support section.

Note: Although this product does not contain any harmful materials, we suggest you return the product to the dealer or directly to the producer after use.

The detector can also be enrolled into the system by entering its production code (3) in the F-Link program or on a keypad (or using a bar code scanner). All numbers stated under the bar code shall be entered (1400-00-0000-0001).

Models: JA-151M, Mini Wireless Magnetic Door Detector, JA-151M Mini Wireless Magnetic Door Detector, Wireless Magnetic Door Detector, Magnetic Door Detector, Door Detector, Detector

File Info : application/pdf, 1 Pages, 44.21KB

PDF preview unavailable. Download the PDF instead.

Manual de instalare Mini contact magnetic wireless JABLOTRON 100 JA-151M adresabil 100 m alb 1

References

Acrobat Distiller 9.5.2 (Windows)

Related Documents

Preview JABLOTRON JA-115M Series Bus Mini Magnetic Detector Technical Specifications and Installation Guide
Comprehensive technical specifications and installation guide for the JABLOTRON JA-115M series bus mini magnetic detector (JA-115M, JA-115M-BR, JA-115M-AN, JA-115M-GR), model 1MAG2304LM. Covers installation steps, technical parameters, system compatibility, and compliance information for use with JABLOTRON security systems.
Preview Jablotron JA-183M Wireless Magnetic Door Detector Installation and Technical Guide
Comprehensive guide to installing, configuring, and maintaining the Jablotron JA-183M wireless magnetic door detector, including technical specifications and compliance information.
Preview JABLOTRON JA-115M Series Bus Mini Magnetic Detector Installation and Technical Guide
Comprehensive guide for the JABLOTRON JA-115M series bus mini magnetic detector, covering installation, system assignment, and technical specifications for security systems.
Preview Jablotron JA-153M Series Wireless Magnetic Detector - Technical Specifications and Installation
Detailed information on the Jablotron JA-153M series wireless magnetic detector, including installation guide, technical specifications, and system registration. Model 5MAG2203SA.
Preview JA-110P PIR Motion Detector Installation and Technical Guide
Comprehensive guide for the JABLOTRON JA-110P PIR motion detector, covering installation, internal adjustments, detection characteristics, technical specifications, and compliance information.
Preview Jablotron JA-115M Bus Mini Magnetic Detector Installation and Technical Guide
Comprehensive guide for the Jablotron JA-115M bus mini magnetic detector, covering installation, system enrollment, and technical specifications. Learn how to integrate this security component into your Jablotron system.
Preview Jablotron Security Systems for Home and Business
Discover Jablotron's reliable and scalable security solutions for homes and businesses. Explore features like easy operation, comprehensive protection against intrusion, fire, gas, and water damage, and smart home integration.
Preview Jablotron JA-153M Series Wireless Magnetic Detector: Installation and Technical Specifications
Comprehensive guide for the Jablotron JA-153M, JA-153M-AN, and JA-153M-GR wireless magnetic detectors. Covers installation, internal settings, calibration, communication, battery replacement, and technical specifications.