The JA-110B is part of the JABLOTRON system. It is used to detect broken panes and glass surfaces in buildings. It reacts to changes in air pressure accompanied by the characteristic sound of breaking glass. The detector has a pulse reaction (reports only its trigger). The detector must be installed by a trained technician with a valid certificate issued by an authorized distributor.
Installation
⚠️ Always turn off the power when connecting the module to the system bus.
- Open the detector cover by pressing the latch (1) with a flat-head screwdriver.
- Remove the circuit board - it is held by a latch (5).
- Insert the bus cable and screw the rear cover part to the wall.
- Reinsert the circuit board and connect the bus cables to the bus terminals (6).
- Set the acoustic sensor sensitivity using the trimmer (10).
- Close the detector cover.
Figure 1: Description of the product's external and internal parts
- 1 - latch
- 2 – acoustic sensor opening
- 3 – light guide
- 4 – acoustic sensor
- 5 – PCB latch
- 6 – bus terminals
- 7 – serial number
- 8 – red LED activation indicator
- 9 – yellow LED fault indicator
- 10 – sensitivity adjustment trimmer
- 11 – tamper contact
Registration in the System
Depending on the type of control panel, use the recommended software or application, see the control panel manual.
Technical Specifications
Feature | Specification |
---|---|
Power | from control panel bus 12 V (9...15 V) |
Quiescent current consumption | 5 mA |
Maximum current consumption | 5 mA |
Recommended installation height | 2.5 m above the floor |
Detection range | up to 9 meters |
Minimum window pane size | 0.6 x 0.6 m |
Stabilization time after power-on | max. 60 seconds |
Dimensions | 40 x 100 x 22 mm |
Weight | 50 g |
Classification | Security Class II / Environmental Class II (according to EN 50131-1) |
Environment | indoor general |
Operating temperature range | -10 °C to +40 °C |
Average operating humidity | 75% RH without condensation |
Certification body | Trezor Test sro (No. 3025), Kiwa Nederland bv |
In accordance with | EN 50131-1, -2-7-1, T 031, EN 50130-4, EN 55032, EN IEC 63000 |
Recommended screw | 2x 3.5 x 40 mm (countersunk head) |
Compliance and Disposal
JABLOTRON a.s. hereby declares that the JA-110B complies with the relevant harmonisation legislation of the European Union: Directive No.: 2014/30/EU, 2011/65/EU, when used as intended. The original Declaration of Conformity can be found in the download section of www.jablotron.com.
CE
UK CA
Note: By disposing of this product correctly, you save valuable resources and prevent potential negative effects on human health and the environment, which could otherwise arise from improper waste disposal. Please return the product to the retailer or contact your local authority for more information on the nearest collection point.