Product Overview

The JA-110B is an acoustic detector designed to identify the breaking of glass and glazed surfaces within buildings. It operates by reacting to changes in air pressure and the characteristic sound produced by breaking glass. This detector functions on a pulse basis, signaling only when triggered. Installation requires a qualified technician with a valid certificate from an authorized distributor.

Installation Guide

Important: Always disconnect the power supply before connecting the module to the system bus.

  1. Open the detector cover by pressing the latch (1) with a flat-head screwdriver.
  2. Remove the Printed Circuit Board (PCB); it is secured by a latch (5).
  3. Insert the bus cable and attach the rear part of the cover to the wall.
  4. Reinsert the PCB and connect the bus cables to the bus terminals (6).
  5. Adjust the sensitivity of the acoustic sensor using the trimmer (10).
  6. Close the detector cover.

Product Parts Description (Figure 1)

The following describes the external and internal components of the JA-110B:

  • 1: Cover latch
  • 2: Hole for acoustic sensor
  • 3: Light guide
  • 4: Acoustic sensor
  • 5: Printed circuit board (PCB) latch
  • 6: Bus terminals
  • 7: Serial number
  • 8: Activation indicator (red LED)
  • 9: Fault indicator (yellow LED)
  • 10: Trimmer for sensitivity adjustment
  • 11: Tamper contact

System Enrollment

To enroll the JA-110B into the JABLOTRON system, use the recommended software or application specific to your control panel type. Consult your control panel's manual for detailed instructions.

Technical Specifications

ParameterSpecification
PowerFrom the control panel bus
Nominal Voltage12 V (9-15 V)
Standby current consumption5 mA
Maximum current consumption5 mA
Recommended installation height2.5 m above the floor
Detection distanceUp to 9 m
Minimum glass size0.6 x 0.6 m
Stabilization time after power-upMax. 60 s
Dimensions40 x 100 x 22 mm
Weight50 g
ClassificationSecurity Class II / Environmental Class II (according to EN 50131-1)
EnvironmentGeneral indoor
Operating temperature range-10 °C to +40 °C
Operating humidity75 % RH, non-condensing
Certification bodyTrezor Test s.r.o. (No. 3025), Kiwa Nederland B.V.
Conformity toEN 50131-1, -2-7-1, T 031, EN 50130-4, EN 55032, EN IEC 63000
Recommended screw2x Ø 3.5 x 40 mm (countersunk head)

Declaration of Conformity

JABLOTRON a.s. hereby declares that the JA-110B is in compliance with the European Union harmonization legislation: Directives No. 2014/30/EU and 2011/65/EU, when used in accordance with its intended purpose. The original Declaration of Conformity is available on www.jablotron.com, in the Downloads section.

Disposal Information

Note: Proper disposal of this product is essential for preserving valuable resources and preventing potential negative impacts on human health and the environment from improper waste management. Please return the product to your retailer or contact your local municipality for the nearest collection point.

Additional Information

An accompanying QR code provides access to an electronic version of this manual (available in other languages) or a version intended for installation in the JA-100+ system.

PDF preview unavailable. Download the PDF instead.

ja-110b leg fr from en origin mlx53109 Adobe PDF Library 25.1.97

Related Documents

Preview JA-110B Acoustic Glass Break Detector for Bus - JABLOTRON
Technical specifications and installation guide for the JABLOTRON JA-110B acoustic glass break detector, designed for bus systems. Learn about its features, installation steps, and technical data.
Preview JABLOTRON JA-110B Bus Acoustic Glass Break Detector - Installation and Specifications
Comprehensive guide to the JABLOTRON JA-110B Bus acoustic glass break detector, covering installation, technical specifications, and system integration for security applications.
Preview JABLOTRON JA-110B Acoustic Glass Break Detector for Buses - Installation and Specifications
Detailed installation guide and technical specifications for the JABLOTRON JA-110B acoustic glass break detector, designed for bus applications. Learn about its features, installation steps, and compliance.
Preview JABLOTRON JA-110B Acoustic Glass Break Detector for Buses | Installation & Specifications
Comprehensive guide to the JABLOTRON JA-110B acoustic glass break detector for buses, covering installation procedures, system registration, and detailed technical specifications.
Preview JABLOTRON JA-110B Acoustic Glass Break Detector: Installation and Specifications
A comprehensive guide to the JABLOTRON JA-110B acoustic glass break detector, detailing its installation, technical specifications, system integration, compliance, and responsible disposal. Suitable for security system installers.
Preview JA-111H TRB Bus Module – Interface for Wired Detectors
Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. It details installation steps, wiring, and product features.
Preview JABLOTRON JA-110B Bus Acoustic Glass Break Detector Installation and Specifications
Technical specifications and installation guide for the JABLOTRON JA-110B, a bus-powered acoustic glass break detector designed for detecting broken glass in buildings.
Preview Jablotron JA-110A II Bus Internal Siren with Battery Backup - Technical Specifications and Installation
Detailed information on the Jablotron JA-110A II Bus Internal Siren, including technical specifications, installation guide, and system integration. Learn about its features, power requirements, sound output, and environmental considerations.