Product Overview
The JA-110B is an acoustic detector designed to identify the breaking of glass and glazed surfaces within buildings. It operates by reacting to changes in air pressure and the characteristic sound produced by breaking glass. This detector functions on a pulse basis, signaling only when triggered. Installation requires a qualified technician with a valid certificate from an authorized distributor.
Installation Guide
Important: Always disconnect the power supply before connecting the module to the system bus.
- Open the detector cover by pressing the latch (1) with a flat-head screwdriver.
- Remove the Printed Circuit Board (PCB); it is secured by a latch (5).
- Insert the bus cable and attach the rear part of the cover to the wall.
- Reinsert the PCB and connect the bus cables to the bus terminals (6).
- Adjust the sensitivity of the acoustic sensor using the trimmer (10).
- Close the detector cover.
Product Parts Description (Figure 1)
The following describes the external and internal components of the JA-110B:
- 1: Cover latch
- 2: Hole for acoustic sensor
- 3: Light guide
- 4: Acoustic sensor
- 5: Printed circuit board (PCB) latch
- 6: Bus terminals
- 7: Serial number
- 8: Activation indicator (red LED)
- 9: Fault indicator (yellow LED)
- 10: Trimmer for sensitivity adjustment
- 11: Tamper contact
System Enrollment
To enroll the JA-110B into the JABLOTRON system, use the recommended software or application specific to your control panel type. Consult your control panel's manual for detailed instructions.
Technical Specifications
Parameter | Specification |
---|---|
Power | From the control panel bus |
Nominal Voltage | 12 V (9-15 V) |
Standby current consumption | 5 mA |
Maximum current consumption | 5 mA |
Recommended installation height | 2.5 m above the floor |
Detection distance | Up to 9 m |
Minimum glass size | 0.6 x 0.6 m |
Stabilization time after power-up | Max. 60 s |
Dimensions | 40 x 100 x 22 mm |
Weight | 50 g |
Classification | Security Class II / Environmental Class II (according to EN 50131-1) |
Environment | General indoor |
Operating temperature range | -10 °C to +40 °C |
Operating humidity | 75 % RH, non-condensing |
Certification body | Trezor Test s.r.o. (No. 3025), Kiwa Nederland B.V. |
Conformity to | EN 50131-1, -2-7-1, T 031, EN 50130-4, EN 55032, EN IEC 63000 |
Recommended screw | 2x Ø 3.5 x 40 mm (countersunk head) |
Declaration of Conformity
JABLOTRON a.s. hereby declares that the JA-110B is in compliance with the European Union harmonization legislation: Directives No. 2014/30/EU and 2011/65/EU, when used in accordance with its intended purpose. The original Declaration of Conformity is available on www.jablotron.com, in the Downloads section.
Disposal Information
Note: Proper disposal of this product is essential for preserving valuable resources and preventing potential negative impacts on human health and the environment from improper waste management. Please return the product to your retailer or contact your local municipality for the nearest collection point.
Additional Information
An accompanying QR code provides access to an electronic version of this manual (available in other languages) or a version intended for installation in the JA-100+ system.