JABLOTRON JA-110B
Acoustic Glass Break Detector for Buses
This document has been machine-translated from the English original. In case of any ambiguities or doubts, please refer to the original version of the document. If you find any errors or have further questions, please contact technical support (contact information can be found at the end of this document).
Installation
Warning: Always switch off the power when connecting the module to the system bus.
- Open the detector cover by pressing the latch (1) with a flat screwdriver.
- Remove the printed circuit board – it is held by a latch (5).
- Insert the bus cable and screw the back cover to the wall.
- Insert the printed circuit board back and connect the bus cables to the bus terminals (6).
- Set the acoustic sensor sensitivity using the trimmer potentiometer (10).
- Close the detector cover.
Figure 1: Description of external and internal parts of the product
- 1 – Cover latch
- 2 – Opening for acoustic sensor
- 3 – Light guide
- 4 – Acoustic sensor
- 5 – Printed circuit board latch
- 6 – Bus terminals
- 7 – Serial number
- 8 – Red LED indicator for activation
- 9 – Yellow LED indicator for malfunction
- 10 – Sensitivity trimmer adjustment
- 11 – Tamper contact
System Registration
Depending on the control panel type, use the recommended software or application; see the control panel's operating instructions.
Technical Specifications
Specification | Value |
---|---|
Power | from the control panel bus 12 V (9...15 V) |
Quiescent current consumption | 5 mA |
Maximum current consumption | 5 mA |
Recommended installation height | 2.5 m above the floor |
Detection range | up to 9 m |
Minimum window glass size | 0.6 x 0.6 m |
Stabilization time after power-on | max. 60 s |
Dimensions | 40 x 100 x 22 mm |
Weight | 50 g |
Classification | Class II safety / Class II environmental (according to EN 50131-1) |
Environment | general premises |
Operating temperature range | -10 °C to +40 °C |
Average operating humidity | 75% relative humidity without condensation |
Certification body | Trezor Test sro (No. 3025), Kiwa Nederland bv |
Conforms to | EN 50131-1, -2-7-1, T 031, EN 50130-4, EN 55032, EN IEC 63000 |
Recommended screw | 2x Ø 3.5 x 40 mm (countersunk head) |
Compliance and Notes
JABLOTRON a.s. hereby declares that the JA-110B complies with the current harmonized legislation of the European Union: Directives No. 2014/30/EU, 2011/65/EU, provided it is used as intended. The original declaration of conformity can be found on the website www.jablotron.com – in the 'Downloads' section.
Note: Proper disposal of this product helps conserve valuable resources and prevent any potential negative impact on human health and the environment that could result from improper waste handling. Please return the product to your dealer or contact your local authorities for information on the nearest collection point.
To obtain an electronic version of this document (available in other languages) or an installation version for JA-100+, scan the attached QR code.