JABLOTRON JA-110B Bus Acoustic Glass Break Detector
Installation and Technical Specifications
Introduction
This document is a machine translation from the English original. In case of any uncertainty or doubt, please refer to the original version of the document. If you find any errors or have further questions, please contact technical support (contact details are at the end of the document).
The JA-110B detector is part of the JABLOTRON system. It detects the breaking of glass and glass surfaces in buildings. It reacts to air pressure changes accompanied by the characteristic sound of breaking glass. The detector has an impulse reaction (indicates activation only). The detector must be installed by a qualified professional certified by an authorized distributor.
Installation
⚠️ Always switch off the power supply when connecting the module to the system bus.
- Open the detector cover by pressing the latch (1) with a flat-head screwdriver.
- Remove the PCB – it is held by a latch (5).
- Insert the bus cable and screw the back cover to the wall.
- Replace the PCB and connect the bus cables to the bus connectors (6).
- Adjust the acoustic detector sensitivity using the trimmer (10).
- Close the detector cover.
Figure 1: Description of the product's external and internal parts
- 1 - cover latch
- 2 - opening for acoustic detector
- 3 - light guide
- 4 - acoustic detector
- 5 - PCB latch
- 6 - bus connectors
- 7 - serial number
- 8 - red LED activation indicator
- 9 - yellow LED fault indicator
- 10 - sensitivity adjustment knob
- 11 - tamper switch
System Registration
Depending on the control panel type, use the recommended software or application, see the control panel manual.
Technical Specifications
Specification | Value |
---|---|
Power | From the central unit bus 12 V (9...15 V) |
Quiescent current | 5 mA |
Maximum current | 5 mA |
Recommended installation height | 2.5 meters above the floor |
Detection range | up to 9 meters |
Minimum window pane size | 0.6 x 0.6 meters |
Stabilization time after power-on | max. 60 sec |
Dimensions | 40 x 100 x 22 mm |
Weight | 50 grams |
Classification | Security class II / Environmental class II (according to EN 50131-1 standard) |
Environment | Indoor general |
Operating temperature range | -10 °C to +40 °C |
Average operating humidity | 75% relative humidity, non-condensing |
Certification body | Trezor Test sro (no. 3025), Kiwa Nederland bv |
Conformity | EN 50131-1, -2-7-1, T 031, EN 50130-4, EN 55032, EN IEC 63000 |
Recommended screw | 2x 3.5 x 40 mm (countersunk head) |
Declaration of Conformity
JABLOTRON a.s. hereby declares that the JA-110B device is in compliance with the relevant European Union harmonisation legislation: Directives 2014/30/EU and 2011/65/EU when used as intended. The original copy of the conformity assessment is available on the www.jablotron.com website in the Downloads section.
Product Disposal
Note: Proper disposal of the product helps conserve valuable resources and prevents potential negative impacts on human health and the environment, which could otherwise arise from improper waste management. Please return the product to your retailer or contact your local municipality regarding the nearest designated collection point.