Hikvision Video Intercom Villa Door Station (DS-KV61X3-(W)PE1(C))
1. Appearance
The villa door station features the following components:
- 1 Microphone
- 2 Camera
- 3 Indicator
- 4 Button
- 5 Card Reading Area
- 6 Loudspeaker
- 7 Terminals
- 8 Debugging Port (for debugging only)
- 9 TAMPER
- 10 Set Screw
- 11 TF Card Slot
- 12 Network Interface
Indicator Description:
- Unlock: Green light
- Call: Orange light
- Communicate: White light
2. Terminal and Wiring
The terminal functions are as follows:
- NC: Door Lock Relay Output (Normally Closed)
- NO: Door Lock Relay Output (Normally Open)
- COM: Common Interface
- AIN1: For access of Door Contact
- AIN3: For access of Exit Button
- AIN2 & AIN4: Reserved
- 485-: RS-485 Interface (Reserved)
- 485+: RS-485 Interface (Reserved)
- 12 VDC IN: Power Supply Input
- GND: Grounding
Note: The RS-485 terminal is not supported.
3. Installation Accessory
Included accessories for installation:
- Mounting Template
- Mounting Plate (Dimensions: 102.58 mm x 39.24 mm x 6.2 mm)
4. Installation
The video intercom villa door station supports surface mounting.
Before You Start:
- Ensure all related equipment is powered off during installation.
- Required tools: Drill (ø2.846) and gradienter.
- It is recommended to purchase a protective shield before installation.
Surface Mounting without Protective Shield:
- Stick the mounting template on the wall and drill screw holes according to the template. Remove the template.
- Secure the mounting plate on the wall using the 4 supplied screws.
- Install the villa door station onto the mounting plate and fix it with the set screw.
Note: Apply silicone sealant around the cable wiring area to prevent water ingress.
Surface Mounting with Protective Shield:
- Stick the mounting template on the wall and drill screw holes according to the template. Remove the template.
- Align the protective shield with the mounting template.
- Secure the mounting plate and protective shield on the wall using the 4 supplied screws.
- Install the villa door station onto the mounting plate and fix it with the set screw.
Note: Installation with a protective shield is advised for outdoor use.
Recommended Installation Height:
The distance between the camera and the ground should be between 1.4 m and 1.6 m. The optimal height is approximately 1.4 m, with a horizontal viewing angle of 129° and a vertical viewing angle of 75°.
5. Configuration via Web
1. Activate Device via Web:
The device must be activated by setting a strong password before use.
- Default IP Address: 192.0.0.65
- Default Port No.: 8000
- Default User Name: admin
- Power on the device and connect it to the network.
- Enter the IP address into your web browser and navigate to the activation page. (Ensure your computer and the device are on the same subnet).
- Create and confirm a strong password.
- Click OK to activate the device.
Note: Basic operations and remote configuration are unavailable until the device is activated.
2. Access Device via Web Browsers:
- Enter the device's IP address in your browser's address bar and press Enter.
- Enter the username and password, then click Login.
3. Communicate with Indoor Station:
- Navigate to Settings -> Intercom -> Press Button to Call.
- Set the call number for each button. You can also set a Call Management Center, which has higher privilege.
- Press the button to call the indoor station.
4. Issue Card:
- Navigate to Settings -> Access Control and Elevator Control -> Issue Card.
- Present the card to the card reading area.
- A confirmation window will appear upon completion.
Note: Supports M1 cards. Up to 10,000 cards can be managed.
5. Unlock Door:
Present an issued card to the card reading area to unlock the door.
Detailed Terminal and Wiring Descriptions
2.1 Terminal Description
The door station terminals include:
- Orange: RS-485+ (Reserved)
- Yellow: RS-485- (Reserved)
- Red: 12 VDC (Power Input)
- Black: GND (Grounding)
- White: AIN1 (Door Contact)
- White: AIN2 (Reserved)
- White: AIN3 (Exit Button)
- White: AIN4 (Reserved)
- Yellow: NC (Door Lock Relay Output NC)
- Green: COM (Common Interface)
- Blue: NO (Door Lock Relay Output NO)
- Black: GND (Grounding)
Note: The RS-485 terminal is not supported.
2.2 Wiring Description
2.2.1 Door Lock Wiring:
For magnetic locks or electric bolts, use the NC/COM terminals. For electric strikes, use the NO/COM terminals.
2.2.2 Door Contact Wiring:
Connect the door contact sensor to the AIN1 terminal.
2.2.3 Exit Button Wiring:
Connect the exit button to the AIN3 terminal.