DJI Power 1000 V2 Safety Guidelines and Specifications
This document outlines the safety guidelines and technical specifications for the DJI Power 1000 V2. Please read and understand all instructions before use.
Safety at a Glance
By using this product, you signify that you have read, understood, and accepted the terms and conditions of this guideline and all instructions. DJI is not responsible for any losses incurred due to improper use of the product. This product is not intended for children.
Safety Instructions
WARNING:
- Ensure the power station is effectively and reliably grounded before charging. Use the provided AC power cable with a grounding conductor and plug. Connect to a properly installed and grounded outlet according to local laws and regulations. Improper grounding can lead to electric shock.
- When using fast recharge mode, ensure connected outlets and cables meet AC input specifications to avoid tripping or fire hazards.
- DO NOT disassemble or modify the power station to prevent fire, electric shock, or injury.
- The electrolytes are highly corrosive. If contact occurs with skin or eyes, wash immediately with water and seek medical attention.
- DO NOT place fingers or hands inside the power station.
- Keep the power station out of reach of children and pets.
- NEVER disassemble or puncture the power station. Doing so may cause leaks, fire, or explosion.
- If the product falls into water, wait over 4 hours before retrieving it. Take anti-electric shock precautions before touching. Place in a dry, open area away from flammable materials and contact official support for instructions. DO NOT reuse the power station. Dispose of according to local regulations.
- DO NOT use non-official components or accessories. Contact official support for repairs or replacements. Users are responsible for accidents caused by using non-official parts.
- DO NOT use damaged batteries. Contact official support in such cases.
- DO NOT insert bare cables or metal objects into the ports, as this will cause a short circuit.
- DO NOT use the power station with damaged cables.
- When not in use, remove the AC cable and all connected devices. Pull the plug, not the cord, to reduce the risk of damage.
- DO NOT allow contact with any liquids. DO NOT leave the power station in the rain or near moisture sources.
- DO NOT use or store near heat sources like furnaces or heaters.
- DO NOT use in strong electrostatic (e.g., thunderstorms) or electromagnetic environments.
- DO NOT use a battery that has been involved in a crash or heavy impact.
- Ensure use in a well-ventilated environment. DO NOT block heat dissipation vents, as this can cause damage from overheating and fire hazards.
- Ensure use at the specified operating temperature. High temperatures can cause fire or explosion; low temperatures reduce battery performance.
- This product is not recommended for powering medical emergency equipment related to personal safety, including ventilators and artificial lungs. Follow doctor's instructions and contact the manufacturer for restrictions. For general medical equipment, monitor power status to prevent depletion.
- The power station generates electromagnetic fields that may affect medical implants or personal medical equipment (e.g., pacemakers, cochlear implants, hearing aids, defibrillators). Contact the manufacturer for restrictions and maintain a safe distance between implants and the power station.
- If connected to a refrigerator, power fluctuations may cause automatic shutdown. To ensure continuous power for refrigerators storing medicine or valuables, press and hold the AC output button. Monitor power status.
- The power station cannot be carried onto an airplane. Comply with local civil aviation transport regulations.
- DO NOT place near explosive or hazardous materials or metal objects like glasses, watches, jewelry, and hairpins.
- Transport with original packaging. Power off and disconnect from other devices during transport.
- DO NOT attempt to transport damaged batteries.
- DO NOT store the power station completely discharged for extended periods, as this can lead to over-discharge and irreparable battery cell damage.
Specifications
Model | DYM1000V2L/DYM1000V2H |
---|---|
Capacity | 1024 Wh |
Battery Type | LFP |
AC Output [1] | DYM1000V2L: 100-120 V AC, Max. 20 A, 50/60 Hz DYM1000V2H: 220-240 V AC, Max. 10.9 A, 50/60 Hz |
AC Output (Bypass Mode) | DYM1000V2L: 100-120 V AC, Max. 12 A DYM1000V2H: 220-240 V AC, Max. 10 A |
USB-A Output | 5V=3A/9V=2A/12V=2A |
USB-C Output | 5/9/12/15/20/28 V = 5 A |
SDC Output | SDC: 9-28 V, Max. 10 A; 32-58.4 V, Max. 42 A SDC Lite: 9-27 V, Max. 10 A |
AC Input | DYM1000V2L: 100-120 V AC, Max. 13 A DYM1000V2H: 220-240 V AC, Max. 7 A |
SDC Input | SDC: 32-58.4 V DC, Max. 60 A SDC Lite: 32-58.4 V DC, Max. 8 A |
Power Supply Temperature | -10° to 45° C (14° to 113° F) |
Recharging Temperature | 0° to 45° C (32° to 113° F) |
Operating Frequency and Transmitter Power (EIRP) [2] | Wi-Fi (802.11 b/g/n): 2.4000-2.4835 GHz: <20 dBm (FCC/CE/SRRC/MIC) Bluetooth 5.0: 2.4000-2.4835 GHz: <10 dBm |
[1] AC output data varies by country and region.
[2] Allowed operating frequency varies among countries and regions. Please refer to local laws and regulations for more information.
Compliance Information
FCC Compliance Notice
Supplier’s Declaration of Conformity
Product name: POWER 1000 V2
Model Number: DYM1000V2L
Responsible Party: DJI Research LLC
Responsible Party Address: 17301 Edwards Road, Cerritos, CA 90703
Website: www.dji.com
We, DJI Research LLC, declares that the above mentioned model was tested to demonstrate complying with all applicable FCC rules and regulations. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
RF Exposure Information
This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm during normal operation. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
ISED Compliance Notice
CAN ICES-003 (B) / NMB-003(B)
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1)This device may not cause interference. (2)This device must accept any interference, including interference that may cause undesired operation of the device.
The device complies with RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
EU & UK Compliance Notice
EU Compliance Statement: SZ DJI TECHNOLOGY CO., LTD. hereby declares that this device (POWER 1000 V2 (DYM1000V2H)) is in compliance with the essential requirements and other relevant provisions of the Directive 2014/53/EU, Directive 2012/19/EU (WEEE), Directive 2011/65/EU (ROHS), and Regulation 1907/2006 (REACH). A copy of the EU Declaration of Conformity is available online at www.dji.com/euro-compliance. EU contact address: DJI GmbH, Industriestrasse 12, 97618, Niederlauer, Germany.
GB Compliance Statement: SZ DJI TECHNOLOGY CO., LTD. hereby declares that this device (POWER 1000 V2 (DYM1000V2H)) is in compliance with the essential requirements and other relevant provisions of Radio Equipment Regulations 2017, the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012. A copy of the GB Declaration of Conformity and PSTI SOC are available online at www.dji.com/euro-compliance.
Environmentally friendly disposal
Old electrical appliances must not be disposed of together with the residual waste, but have to be disposed of separately. The disposal at the communal collecting point via private persons is for free. The owner of old appliances is responsible to bring the appliances to these collecting points or to similar collection points. With this little personal effort, you contribute to recycle valuable raw materials and the treatment of toxic substances.