JA-110P PET - Bus PIR Motion Detector with Basic Pet Immunity
Product Overview
This document has been machine-translated from the English original. In case of ambiguities or doubts, refer to the original version of the document. If you encounter any errors or have further questions, contact technical support (contact details at the end of this document).
The JA-110P PET is a bus device in the JABLOTRON system. It is used to detect the movement of people in buildings. Unlike standard PIR motion detectors in the JABLOTRON series, this detector has a modified detection characteristic and is equipped with basic pet immunity. The detector eliminates the effects of small animals' movements on the floor (animals weighing up to approx. 25 kg and a maximum height of 40 cm). The detector has a pulse reaction and takes up a position in the system. The detector should be installed by a trained technician with a valid certificate issued by an authorized distributor.
Installation
Note: When connecting the detector to the bus, always turn off the system's power supply. ⚡
- Open the detector's cover by pressing the cover tab (5). Avoid touching the PIR sensor inside (11) – it can be damaged.
- Remove the circuit board – it is held by a tab (3).
- Make holes for screws and cable in the plastic base. The recommended installation height for the detector is 2 m above the floor.
- Insert the bus cable and attach the plastic base to the wall with screws (vertically, with the cover tab facing down).
- Reinsert the circuit board and connect the cables to the terminals (8).
- Proceed by following the installation manual for the control panel.
Diagram 1: Detector Parts
Figure 1 shows the detector opened and describes its internal and external parts:
- 1 – Hole for installation on a flat wall
- 2 – Hole for corner installation (in a corner)
- 3 – PCB tab
- 4 – Hole for corner installation (in a corner)
- 5 – Protective tab
- 6 – Red LED – activation
- 7 – Yellow LED – fault
- 8 – Bus terminals
- 9 – Production code
- 10 – Tamper sensor for protection
- 11 – PIR sensor
Assignment to the System and Settings
Depending on the type of control panel, use the recommended software or application; refer to the control panel manual.
Technical Specifications
Power | from control panel bus 12 V (8...15 V) |
Quiescent current consumption | 5 mA |
Maximum current consumption | 10 mA |
Recommended installation height | 2 m above floor |
Detection angle/detection range | 90°/12 m |
Detection angle/detection coverage - pet immunity | 90°/7 m |
Dimensions | 60 x 98 x 52 mm |
Weight | 75 g |
Classification | Class 2/II. General indoor use (according to EN 50131-1) |
Operating environment | Indoor general |
Operating temperature range | -10 °C to +40 °C |
Average operating humidity | 75% RH, non-condensing |
Certification body | Trezor Test s.r.o. (No. 3025), KIWA Nederland bv |
Also complies with | EN 50131-1, EN 50131-2-2, EN 50130-4, EN 55032, EN IEC 63000, T 031. |
Recommended screw | 2x 3.5 x 40 mm (countersunk head) |
Compliance and Disposal
JABLOTRON a.s. hereby declares that the JA-110P PET complies with the relevant harmonisation legislation of the European Union: Directive No: 2014/30/EU, 2011/65/EU, when used as intended. The original Declaration of Conformity is available at www.jablotron.com – downloads section.
Note on Disposal: By disposing of this product correctly, you save valuable resources and prevent potential negative effects on human health and the environment, which could otherwise arise from improper waste disposal. Please return the product to the retailer or contact your local authority for more information on the nearest collection point. ♻️