JA-180W Wireless Combined PIR + MW Detector

Introduction

The JA-180W is a component of the JABLOTRON alarm system, designed to detect human body movement inside buildings. It achieves high immunity to false alarms through the combination of PIR and microwave (MW) detection. The detector functions like a standard PIR detector, but the MW part confirms PIR detector activation, sending information to the control panel. It requires installation by a trained technician with a valid certificate from an authorized Jablotron distributor and a control panel equipped with a JA-11xR radio module.

Important Note: Always precisely check the PIR and MW coverage of the protected area during installation.

To conserve battery energy, the PIR sensor enters a battery-save mode 15 minutes after the cover is closed. During this mode, the PIR sensor still detects movement. The first detected movement, confirmed by the MW part, is signaled instantly. For the next 5 minutes, the PIR sensor ignores further movement (sleep mode). After this period, it resumes normal operation until re-triggered.

After setting up, switch DIP switch no. 4 back to the NORM position!

Installation

The detector can be mounted on a wall or in a corner of a room. Ensure there are no obstacles blocking the detector's "view" of the protected area. Keep the detector away from metal objects that could interfere with radio communication and the MW field.

Figure 1: Description of internal parts of the product
1 – DIP-switch; 2 – MW part connector; 3 – PCB tab; 4 - tamper-switch; 5 – PIR sensor; 6 - front cover tab; 7 – MW sensitivity setting; 8 – MW detector
  1. Open the detector cover by pressing the tab (6). Avoid touching the internal PIR element (5) as it can be damaged.
  2. Remove the PCB, which is held by a PCB tab (3). Leave the MW connector (2) of the MW part attached.
  3. Punch screw holes through the rear plastic cover. Screw the rear cover to the wall. Ensure at least one screw penetrates the tamper-sensitive section.
  4. Reinsert the PCB until the tab (3) clicks. Insert the battery (mind the correct polarity) and follow the instructions below. After installing a low battery, the LED will be lit for 1 minute.
  5. Close the detector cover until the tab (6) clicks. To comply with EN 50131-2-4, the tab (6) must be secured with the supplied screw.

Enrolment to the system and settings

Refer to the control panel manual for recommended software or application for system enrollment and settings.

Setting DIP switch

Testing the detector

Fifteen minutes after closing the detector cover, the LED indicators will show detector activation. A short flash of the red LED indicates PIR detection, and a long flash (2 seconds) indicates MW confirmation of movement.

The MW detector's reaction span is from 1 m to 15 m. In some cases, it can detect movement outside the monitored room if obstacles are not metal (e.g., thin walls, doors, glass, flowing water in plastic pipes). For proper functioning, the MW detection field must match the PIR detection area. For setup, switch the fourth DIP switch to the TEST position. The RF range of the MW part is adjustable via the trimmer (7). MW activation is indicated by a red LED. Detection characteristics can vary based on the installation environment, particularly due to metal objects causing reflections or shielding the MW signal.

Figure 2: Detection characteristics of PIR and MW coverage in an open area and sample room

Technical parameters

Parameter Value
Power supply Lithium battery type CR14500 (AA) 3.6 V / 2.45 Ah (Battery not included)
Quiescent current consumption 21 μA
Maximal current consumption 38 mA
Low battery voltage ≤ 2.6 V
Typical battery lifetime approx. 2 years (DIP no. 3 to NORM)
Communication frequency 868.1 MHz, Jablotron protocol
Communication range approx. 300 m (open area)
Maximum radiofrequency power (ERP) < 25 mW
Recommended installation height 2.5 m above floor level
PIR detection angle / detection range 110° / 12 m (with basic lens)
MW detection angle / detection range 24° / 15 m (open area without reflections)
MW detection range/frequency 9.35 GHz
Dimensions 110 x 60 x 51 mm
Weight 114 g
Classification Security grade 2 / environmental class II
Operational environment Indoor general according to EN 50131-1
Operational temperature range -10 °C to +40 °C
Average humidity 75% RH, non-condensation
Certification body Trezor Test s.r.o. (no. 3025)
Complies with EN 50131-1, EN 50131-2-4, EN 50131-5-3, ETSI EN 300 220-2, ETSI EN 300 440-1, EN 50131-6, EN 50130-4, EN 55032, EN 62368-1
Can be operated according to ERC REC 70-03
Recommended screw 2x Ø 3.5 x 40 mm (countersunk head)

We recommend familiarizing yourself with the terms and conditions set by local telecommunications authorities.

Note: This detector must not be used in Great Britain as this frequency band is allocated for radar level measurements applications. In Russia, the e.i.r.p is limited to 13 dBm (approx. 20 mW).

JABLOTRON a.s. declares that the JA-180W complies with Union harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The original conformity assessment can be found at www.jablotron.com - Section Downloads.

Disposal Information: Please return this product to your dealer or contact your local authority for proper disposal to prevent negative effects on human health and the environment.

For the electronic version of this document, or the version for installation in a JABLOTRON 100+ system, scan the QR code.

JABLOTRON a.s. | Pod Skalkou 4567/33 | 46601 Jablonec n. N. | Czech Republic | www.JABLOTRON.com

Model: MLI55607

Models: JA-180W, JA-180W Wireless Combined PIR Plus MW detector, JA-180W, Wireless Combined PIR Plus MW detector, Combined PIR Plus MW detector, PIR Plus MW detector, MW detector

File Info : application/pdf, 1 Pages, 692.29KB

PDF preview unavailable. Download the PDF instead.

JA-180W EN LEG MLI55607

References

Adobe PDF Library 25.1.51

Related Documents

Preview Jablotron JA-103KR GSM Control Panel with LAN and Radio Module
Overview and technical specifications for the Jablotron JA-103KR GSM Control Panel, a core component of the JABLOTRON 100+ security system for family houses, offices, and small businesses. Details features, compatibility, and compliance standards.
Preview Jablotron JA-110A II Bus Internal Siren with Battery Backup - Technical Specifications and Installation
Detailed information on the Jablotron JA-110A II Bus Internal Siren, including technical specifications, installation guide, and system integration. Learn about its features, power requirements, sound output, and environmental considerations.
Preview Jablotron JA-110A II Internal Siren with Backup Battery - Installation and Specifications
Detailed information on the Jablotron JA-110A II internal siren, including installation instructions, technical specifications, and system integration. This document provides guidance for installers and users.
Preview JABLOTRON JA-110A II Internal Bus Siren with Backup Battery - Installation and Specifications
Detailed installation guide and technical specifications for the JABLOTRON JA-110A II internal bus siren with backup battery. Learn about its features, installation steps, and compliance.
Preview JABLOTRON JA-110A II Internal Bus Siren with Battery Backup
JABLOTRON JA-110A II is an internal bus siren for alarm systems, featuring battery backup, tamper detection, and a piezo siren. This document provides installation and specification details.
Preview Jablotron JA-110A II Interior Bus Siren with Backup Battery - Installation and Features
Detailed information on the Jablotron JA-110A II interior bus siren, including installation instructions, technical specifications, and features. Learn about its backup battery, siren type, and environmental classifications.
Preview JA-111H TRB Bus Module – Interface for Wired Detectors
Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. It details installation steps, wiring, and product features.
Preview Jablotron JA-110B Acoustic Glass Break Detector - Installation and Specifications
Detailed information on the Jablotron JA-110B acoustic glass break detector for bus systems, including installation guide, technical specifications, and compliance details.