JA-110A II Internal Bus Siren with Battery Backup
Brand: JABLOTRON
Website: www.jablotron.com
Product Overview
The JA-110A II is an internal bus siren designed for alarm signaling within premises, as part of the JABLOTRON system. It features a button that can mute active alarms, confirm presence, or trigger a panic alarm. The siren requires one bus position and must be installed by a qualified technician certified by an authorized distributor.
Note: This document was machine-translated from the original English. In case of any ambiguities or doubts, please refer to the original document version. If you find any errors or have further questions, please contact technical support.
Diagrams and Components
Figure 1: Disassembly of the siren before installation
This diagram illustrates the process of disassembling the siren unit from its mounting frame. It shows the main unit (labeled 3) and indicates pressing a release mechanism on the side of the unit (labeled 1) with a screwdriver to detach it from the frame (labeled 2).
Figure 2: Description of the internal parts of the product
This diagram details the internal components of the siren:
- 1: LED indicators
- 2: Buttons
- 3: Serial number
- 4: Button retainers
- 5: Piezoelectric siren
- 6: Bus terminal
- 7: Tamper sensors
- 8: Connector for BAT-3V2-CR2 battery
Installation Instructions
- Remove the siren cover (buttons) from the plastic frame by pressing the side of the cover (1.) with a screwdriver, as shown in Figure 1.
- Remove the middle frame part (3.) by pressing the 4 clips indicated by arrows (2.).
- Feed the bus cable through the designated rectangular cutout in the plastic base.
- Attach the plastic base to the chosen location using screws. If the siren uses a battery, place it under the upper part of the plastic base, as shown in Figure 1.
- Assemble the plastic frame with the plastic base, which will secure the battery in its correct position.
System Assignment and Configuration
For system assignment and configuration, use the recommended software or application, depending on the control panel type. Refer to the control panel manual for instructions.
Specifications
Parameter | Value |
---|---|
Power | 12 V DC bus (8-15 V) |
Additional backup battery | 3.2 V LiFePo4 CR2 0.4 Ah (Note: battery not included) |
Quiescent current for backup power | 5 mA |
Maximum current consumption for cable selection | 120 mA |
Low battery state | 2.9 V |
Signal device type | Siren |
Dimensions | 80 x 80 x 35 mm |
Weight | 92 g |
Classification | Security grade 2 / Environmental class II (EN 50131-1) |
Operating environment | General purpose indoor |
Operating temperature range | -10 °C to +40 °C |
Average operating humidity | 75% relative humidity, non-condensing |
Certification body | TREZOR TEST s.r.o. (No. 3025) |
Conforms to | EN 50131-1, EN 50131-4, EN 50130-4, EN 55032, EN 62368-1, EN 50581 |
Recommended screw | Ø 3.5 x 40 mm (countersunk head) |
Compliance and Disposal
CE Marking: The product complies with relevant EU harmonisation legislation.
UKCA Marking: The product complies with relevant UK legislation.
JABLOTRON a.s. hereby declares that the JA-110A II is in compliance with the relevant European Union harmonisation legislation: Directives No. 2014/35/EU, 2014/30/EU, 2011/65/EU. The original declaration of conformity can be found on the www.jablotron.com website – Downloads section.
Disposal Note: Proper disposal of this product helps conserve valuable resources and prevent any potential negative impact on human health and the environment that could result from improper waste handling. Please return the product to your dealer or contact your local authorities for information on the nearest collection point.
To obtain an electronic version of this document (available in other languages) or the installation version for JA-100+, please refer to the manufacturer's website.