Aldes W16 BDH 5/30 11015131: Hygrorégulable Ventilation Grille
Simple Flow Hygrorégulable Extraction Grille for Bathrooms and Toilets
Product Overview
The Aldes W16 BDH 5/30 (Model 11015131) is a hygrorégulable extraction grille designed for sanitary rooms such as bathrooms and WCs. It ensures efficient and continuous extraction of indoor pollutants by automatically adjusting airflow based on the room's humidity level.
Key Product Features
- Simplified maintenance with a removable face
- Unique design without an external grille
- Roll-in seal for enhanced airtightness
Operating Principles
In a hygrorégulable VMC (Mechanical Ventilation Controlled) system, airflow is automatically regulated according to room humidity. The BDH grille is installed in sanitary rooms to meet the building's ventilation needs.
Product Description
The BDH grille is ideal for technical rooms in individual homes and collective housing, suitable for both new builds and renovations. It is a compact hygrorégulable grille designed for flow rates below 50 m³/h.
Application Areas
- Collective Residential Housing
- Individual Residential Housing
- New Construction
- Renovation
Installation Guidelines
- Install the BDH grille in humid or technical rooms like bathrooms, WCs, or utility rooms.
- Position the grille at the upper part of a vertical wall or on the ceiling, at least 1.80 meters above the floor.
- Ensure the grille is accessible and removable, with at least 20 cm clearance from adjacent walls and not flush with the duct.
- Optimal airtightness of the grille-duct connection is crucial, improved by using a sleeve. A metal sleeve is required for collective housing (stainless steel for Gas VMC), while a plastic sleeve is suitable for individual homes.
- Grilles with a Ø 125 mm duct attach directly (push-fit with O-ring) into sleeves, RT Flex, or rigid/semi-rigid ducts.
- Grilles with a Ø 80 mm duct attach by push-fit into sleeves or rigid/semi-rigid ducts.
- For cord-controlled grilles installed on the ceiling or above furniture, use a [cord-return] symbol.
- For electrically controlled hygrorégulable grilles, two AA/LR06 batteries and a standard push-button [push-button] symbol are required.
- Hygrorégulable grilles operate within a pressure range of 80-160 Pa.
- Extraction grilles require annual maintenance and checks. Connecting a mechanical hood to the VMC system is prohibited (Art. 14 - decree of March 24, 1982).
- Before replacing an old grille, perform a pressure reading and note the housing type.
Technical Specifications
Key Features Summary
- Small hygrorégulable grille (flow rates < 50 m³/h).
- Versions and accessories available to meet diverse installation needs.
- Easy maintenance: clip-on/clip-off regulation sub-assembly. The removable housing allows for easy cleaning without wall removal.
- Pressure range: 80 - 160 Pa.
Accessories
Description | Reference |
---|---|
Foam sealing gasket for grilles | 11019049 |
Acoustic ring for Ø 125 mm grilles | 11019429 |
12V BDH Box | 11015006 |
Interface 230 VAC/ 3 V DC | 11015005 |
Battery box 2X AA/LR06 | 11015007 |
VMC push-button for Bahia Curve PUSH grille and for EasyHOME AutoSENS and PureAIR | 11026011 |
Trident sleeve for RT Flex | 11018569 |
Trident sleeve Ø 125 mm | 11033007 |
Sheet metal sleeve D125 H300 TRIDENT | 11022055 |
Sheet metal sleeve with shoulder Ø 125 mm | 11012220 |
Sheet metal sleeve 3 tabs Ø 125 mm | 11012252 |
Trident hygro sleeve Ø 125/80 mm | 11085343 |
Sleeve Ø 125 straight 1P | 11091867 |
Sleeve Ø 125 90° 1P | 11091865 |
Sleeve Ø 125 90° 2P | 11091866 |
Long sleeve 2X75/D125 | 11091995 |
Vertical elbow 90° for Ø 125 mm grille | 11023975 |
Short sleeve 2X75/D125 | 11091996 |
OPTIFLEX® long sleeve 2x90 ? 125 | 11091997 |
OPTIFLEX® short sleeve 2x90 ? 125 | 11091998 |
Vertical tee 90° for Ø 125 mm grille | 11023979 |
Adapter plate 125/150 | 11018056 |
General Data
Reference | Housing Type (Hygro B) | Main Material | Control Type | Housing Type | Color |
---|---|---|---|---|---|
11015131 | Hygro A; Hygro B; Hygro C | Plastic | Push-button | F1, F2, F3, F4, F5, F6, F7 | White |
Dimensional Data
The grille features a square front face measuring 170 mm in height (H) and 170 mm in width (L). The depth of the front part (P) is 43.1 mm. The overall depth, including the connection, is approximately 65.6 mm. The connection duct diameter is 125 mm.
Reference | H (mm) | L (mm) | P (mm) | Connection Ø (mm) |
---|---|---|---|---|
11015131 | 170 | 170 | 43.1 | 125 |
Aerodynamic Data
Reference | Base Flow (m³/h) | Peak Flow (m³/h) | Pressure Range (Pa) |
---|---|---|---|
11015131 | 5 | 30 | 80-160 |