JABLOTRON JA-111H TRB Bus Module – Interface for Wired Detectors

Introduction

This document provides information on the JABLOTRON JA-111H TRB bus module, an interface for wired detectors. It is a component of the JABLOTRON system, designed to connect wired detectors with NC/NO contact outputs to the control panel's bus. The module supplies power to the detector and reports its activation, tampering, and faults. Installation must be performed by a qualified technician certified by an authorized distributor.

Note: This document was automatically translated from the original English. For any uncertainties or doubts, refer to the original document version. If you encounter errors or have further questions, contact technical support.

Installation

? When connecting the module to the system bus, always disconnect the power supply.

The current consumption of the connected detector must not exceed 50 mA (the module's power output is not overload protected).

The module is designed for installation inside a standard wired detector (with contact outputs), but thanks to extended cables, it can also be installed outside the detector, in a protective installation box. The cable can be extended up to a maximum of 3 meters.

  1. Install the module in a suitable location within the detector or in a protective installation box near the detector.
  2. Connect the wires to the detector (refer to Figure 1).
  3. Connect the bus cable and turn on the control panel power supply.
  4. The control panel must be in service mode.
  5. Close the detector cover with the module installed inside.

Figure 1: Module Internal Parts and Wiring

Figure 1 illustrates the internal parts of the product and the module's wiring. It shows:

Table 1: Module Wires

WireSenseFunction
Red+12 VPower for the detector
BlackGNDCommon wire
WhiteINPAlarm input
BlueTMPAnti-tamper input
YellowTRBTrouble input

Technical Specifications

EnergyFrom the control panel bus 12 V DC (9...15 V)
Standby current consumption8 mA (+ consumption of connected devices) for all inputs connected to GND
Maximum current consumption12 mA (+ consumption of connected devices)
Maximum current for connected detector50 mA
Control device type (ACE)Type B
Dimensions16 x 30 x 12 mm
Weight8 grams
ClassificationSecurity grade 2 / environmental class II (according to EN 50131-1). Note: valid only if integrated into a certified enclosure with security grade 2 or higher.
EnvironmentGeneral indoor
Operating temperature range-10 °C to +40 °C
Average humidity75% RH, non-condensing
Certification bodyTrezor Test sro (No. 3025), Kiwa Nederland bv
Conforms toEN 50130-4, EN 55032, T 031, EN 50131-1, -3, EN IEC 63000

Declaration of Conformity

JABLOTRON a.s. hereby declares that the product JA-111H TRB is in compliance with the relevant EU harmonization legislation: Directives No. 2014/30/EU, 2011/65/EU. The original Declaration of Conformity is available on the website www.jablotron.com - Downloads Section.

Disposal Information

Proper disposal of this product helps conserve valuable resources and prevent potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste disposal. Return the product to the retailer or contact the local authority for more information on the nearest designated collection point.

For an electronic version of this manual (available in other languages) or an installer version for JA-100+, scan the attached QR code.

PDF preview unavailable. Download the PDF instead.

ja-111h-trb leg it from en origin mln20207 Adobe PDF Library 25.1.97

Related Documents

Preview JABLOTRON JA-111H TRB Bus Module - Wired Detector Interface
Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. Learn about wiring, functions, and technical data.
Preview JABLOTRON JA-111H TRB Bus Module for Wired Detectors
The JABLOTRON JA-111H TRB is a bus module designed to connect wired detectors with NC/NO outputs to the JABLOTRON control panel bus. It provides power to the detector and reports its activation, tampering, and faults. Includes technical specifications and installation guide.
Preview JABLOTRON JA-111H TRB Bus Module: Installation and Technical Specifications
Comprehensive guide to the JABLOTRON JA-111H TRB bus module, detailing its function as an interface for wired detectors, installation instructions, wiring diagrams, technical specifications, and compliance information.
Preview JABLOTRON JA-111H TRB Wired Detector Interface Bus Module - Installation and Specifications
Detailed installation guide and technical specifications for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors. Learn about connections, power, and compliance.
Preview JABLOTRON JA-111H TRB Bus Module: Installation and Technical Specifications
Comprehensive guide to the JABLOTRON JA-111H TRB bus module, detailing installation procedures, wiring diagrams, technical specifications, and compliance information for wired detector integration into JABLOTRON alarm systems.
Preview JABLOTRON JA-111H TRB Bus Module - Installation and Technical Specifications
Comprehensive guide to the JABLOTRON JA-111H TRB bus module, covering installation, wiring, technical specifications, and compliance for wired alarm system detectors.
Preview JABLOTRON JA-111H TRB Bus Module: Wired Detector Interface
Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. Includes wiring details, technical data, and compliance information.
Preview JABLOTRON JA-111H TRB Busmodule: Installation and Technical Guide
Comprehensive guide to installing and configuring the JABLOTRON JA-111H TRB busmodule for wired detectors. Includes technical specifications, wiring diagrams, and compliance information.