This document has been machine-translated from the original English version. In case of ambiguities or discrepancies, please refer to the original version of the document. If you find any errors or have further questions, please contact technical support (contact details are provided at the end of this document).
The JA-111H TRB is part of the JABLOTRON system. It is used to connect a wired detector equipped with NC/NO outputs to the control panel bus. It supplies power to the detector and reports its activation, tampering, and faults. The module must be installed by a trained technician holding a valid certificate issued by an authorized dealer.
Installation
Important: When connecting the module to the system bus, always disconnect the power. ⚠️
The current consumption of the connected detector must not exceed 50 mA (the module's power supply output is not protected against overload).
It is designed to be installed inside a standard wired detector (with contact outputs), but thanks to extended wires, it can also be installed outside it in a protected installation box.
- Install the module in a suitable location inside the detector or within a protected installation box near the detector. The wire can be extended up to 3 meters. When installing the module inside the detector, ensure it cannot cause a short circuit due to poor insulation.
- Connect the wires to the detector (as shown in Figure 1).
- Connect the bus cable and turn on the control panel power supply.
- The control panel must be in service mode.
- Close the detector cover with the module installed inside.
Figure 1: Module Wiring Diagram Description
The diagram illustrates the internal components and wiring connections of the module. It shows:
- 1 – Bus connectors
- 2 – Production code
- 3 – LEDs: A yellow LED indicates a fault or an unregistered device. A red LED flashes to indicate the activation of any input.
- 4 – Module wires: Refer to the table below for wire functions.
Wire Color | Meaning | Function |
---|---|---|
Red | +12 V | Detector power |
Black | Ground | Common wire |
White | INP | Alarm input |
Blue | TMP | Tamper input |
Yellow | TRB board | Fault notification |
System Registration and Settings
Use the recommended software or application according to the control panel type – refer to the control panel manual.
Technical Specifications
Power | From the control panel bus 12 V DC (9...15 V) |
Quiescent current consumption | 8 mA (+ consumption of connected devices) all inputs connected to GND |
Maximum current consumption | 12 mA (+ consumption of connected devices) |
Max. allowed current for connected detector | 50 mA |
Control device type (ACE) | Type B |
Dimensions | 16 x 30 x 12 mm |
Weight | 8 grams |
Classification | Protection class 2 / environmental class II (according to EN 50131-1) Note: valid only if built into a protection class 2 or higher certified enclosure |
Environment | Indoors generally |
Operating temperature range | -10 °C - +40 °C |
Average humidity | 75% relative humidity, non-condensing |
Certification body | Trezor Test sro (No. 3025), Kiwa Nederland bv |
Complies with standard | EN 50130-4, EN 55032, T 031, EN 50131-1, -3, EN IEC 63000 |
Declaration of Conformity
JABLOTRON a.s. hereby declares that the product JA-111H TRB is in compliance with the relevant Union harmonisation legislation: Directives No. 2014/30/EU, 2011/65/EU. The original document of conformity assessment can be found at www.jablotron.com – in the Downloads section.
Disposal Information
Note: Proper disposal of this product helps conserve valuable natural resources and prevents potential negative effects on human health and the environment, which could otherwise be caused by improper waste handling. Return the product to the retailer or contact local authorities for more information on the nearest collection point.
Additional Information
You can get the electronic version of this document (available in other languages) or the version to be installed on the JA-100+ device by scanning the QR code provided. [QR code excluded as per instructions].
Related Documents
![]() | JABLOTRON JA-111H TRB Bus Module: Installation and Technical Specifications Comprehensive guide to the JABLOTRON JA-111H TRB bus module, detailing installation procedures, wiring diagrams, technical specifications, and compliance information for wired detector integration into JABLOTRON alarm systems. |
![]() | JABLOTRON JA-111H TRB Bus Module - Wired Detector Interface Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. Learn about wiring, functions, and technical data. |
![]() | JABLOTRON JA-111H TRB Bus Module: Installation and Technical Specifications Comprehensive guide to the JABLOTRON JA-111H TRB bus module, covering installation, wiring, technical specifications, and compliance for wired detector integration into JABLOTRON security systems. |
![]() | JABLOTRON JA-111H TRB Bus Module: Installation and Technical Specifications Detailed guide for the JABLOTRON JA-111H TRB bus module, covering installation, wiring, technical specifications, and compliance for wired detectors in JABLOTRON alarm systems. |
![]() | JABLOTRON JA-111H TRB Bus Module: Installation and Technical Specifications Comprehensive guide to the JABLOTRON JA-111H TRB bus module, detailing its function as an interface for wired detectors, installation instructions, wiring diagrams, technical specifications, and compliance information. |
![]() | JABLOTRON JA-111H TRB Wired Detector Interface Bus Module - Installation and Specifications Detailed installation guide and technical specifications for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors. Learn about connections, power, and compliance. |
![]() | JABLOTRON JA-111H TRB Bus Module - Installation and Technical Specifications Comprehensive guide to the JABLOTRON JA-111H TRB bus module, covering installation, wiring, technical specifications, and compliance for wired alarm system detectors. |
![]() | JA-111H TRB Bus Module – Interface for Wired Detectors Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. It details installation steps, wiring, and product features. |