JABLOTRON JA-111H TRB Bus Module: Installation and Technical Specifications

JABLOTRON JA-111H TRB Bus Module – Interface for Wired Detectors

This document provides technical specifications and installation guidance for the JA-111H TRB bus module.

Installation

Always switch off the power when connecting the module to the system bus. The power consumption of the connected detector must not exceed 50 mA (the module's power supply output is not protected against overload).

The module is intended for installation inside a standard wired detector (with contact outputs), but can also be installed externally in a protected installation box due to its extended cables.

  1. Install the module in a suitable location within the detector or inside the protected installation box near the detector. The cable can be extended up to a maximum of 3 m. When installing the module inside the detector, ensure it cannot be short-circuited due to poor insulation.
  2. Connect the wires to the detector (as per Figure 1).
  3. Connect the bus cable and switch on the power to the control panel.
  4. The control panel must be in service mode.
  5. Close the detector's cover with the installed module inside.

Figure 1: Description of product's internal parts and connection of module cables

The diagram shows the JA-111H TRB module connected to a detector. It illustrates the bus terminals, a production code, status LEDs, and the module's cables.

Connections:

  • Bus terminals (1)
  • Production code (2)
  • LEDs (3): Yellow LED indicates fault/unregistered device, Red LED indicates blinking activation of any input.
  • Module cables (4)
Table 1: Module Wiring
Wire Meaning Function
Red +12 V Power for detector
Black Ground Common wire
White INP Alarm input
Blue TMP Tamper input
Yellow TRB Trouble input

System Registration and Setup

Depending on the type of control panel, use the recommended software or application – refer to the control panel manual.

Technical Specifications

Power From the control panel bus 12 V DC (9...15 V)
Quiescent current consumption 8 mA (+ consumption for connected devices) all inputs connected to GND
Maximum current consumption 12 mA (+ consumption from connected devices)
Maximum allowed current for the connected detector 50 mA
Control unit type (ACE) Type B
Dimensions 16 x 30 x 12 mm
Weight 8 grams
Classification Security Class 2 / Environmental Class II (according to EN 50131-1)
Note: applies only if built into a housing with Security Class 2 or higher certification.
Environment Indoor general
Operating temperature range -10 °C to +40 °C
Average humidity 75% RH, non-condensing
Certifying bodies Trezor Test sro (No. 3025), Kiwa Nederland bv
Complies with EN 50130-4, EN 55032, T 031, EN 50131-1, -3, EN IEC 63000

Compliance Information

JABLOTRON a.s. hereby declares that the product JA-111H TRB complies with the relevant harmonisation legislation of the Union: Directive No: 2014/30/EU, 2011/65/EU. The original declaration of conformity is available at www.jablotron.com – Downloads.

Environmental Protection

By disposing of this product correctly, you save valuable resources and prevent potential negative effects on human health and the environment, which could otherwise arise from improper waste disposal. Please return the product to your reseller or contact your local authority for more information on the nearest collection point.

PDF preview unavailable. Download the PDF instead.

ja-111h-trb leg sv from en origin mln20207 Adobe PDF Library 25.1.97

Related Documents

Preview JABLOTRON JA-111H TRB Bus Module: Installation and Technical Specifications
Comprehensive guide to the JABLOTRON JA-111H TRB bus module, detailing its function as an interface for wired detectors, installation instructions, wiring diagrams, technical specifications, and compliance information.
Preview JABLOTRON JA-111H TRB Bus Module: Wired Detector Interface
Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. Includes wiring details, technical data, and compliance information.
Preview JABLOTRON JA-111H TRB Wired Detector Interface Bus Module - Installation and Specifications
Detailed installation guide and technical specifications for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors. Learn about connections, power, and compliance.
Preview JABLOTRON JA-111H TRB Bus Module: Installation and Specifications
Comprehensive guide to the JABLOTRON JA-111H TRB bus module, detailing its installation, wiring, technical specifications, and compliance for wired alarm system detectors.
Preview JABLOTRON JA-111H TRB Bus Module - Installation and Technical Specifications
Comprehensive guide to the JABLOTRON JA-111H TRB bus module, covering installation, wiring, technical specifications, and compliance for wired alarm system detectors.
Preview JABLOTRON JA-111H TRB Busmodule: Installation and Technical Guide
Comprehensive guide to installing and configuring the JABLOTRON JA-111H TRB busmodule for wired detectors. Includes technical specifications, wiring diagrams, and compliance information.
Preview JABLOTRON JA-111H TRB Bus Module for Wired Detectors
The JABLOTRON JA-111H TRB is a bus module designed to connect wired detectors with NC/NO outputs to the JABLOTRON control panel bus. It provides power to the detector and reports its activation, tampering, and faults. Includes technical specifications and installation guide.
Preview JA-111H TRB Bus Module – Interface for Wired Detectors
Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. It details installation steps, wiring, and product features.