JABLOTRON JA-111H TRB Bus Module – Interface for Wired Detectors

Introduction

The JA-111H TRB module is a component of the JABLOTRON system. It serves to connect wired detectors with NC/NO outputs to the control panel bus. It provides power to the detector and reports its activation, tampering, and faults. The module must be installed by a qualified technician with a valid certificate issued by an authorized distributor.

This document was machine-translated from the original English. In case of any ambiguities or doubts, please refer to the original version of the document. If you find any errors or have further questions, please contact technical support (contact information can be found at the end of this document).

Installation

⚠️ Always disconnect power before connecting the module to the system bus.

The power consumption of a connected detector must not exceed 50 mA (the module's power output is not protected against overload).

It is designed for installation inside a standard wired detector (with contact outputs), but thanks to extended wires, it can also be installed outside it in a protected junction box. The wire can be extended up to 3 meters.

  1. Install the module in a suitable location within the detector or inside a protected junction box near the detector. Ensure that during installation inside the detector, it cannot cause a short circuit due to poor insulation.
  2. Connect the wires to the detector (as per Figure 1).
  3. Connect the bus cable and turn on the control panel power.
  4. The control panel must be in service mode.
  5. Close the detector cover with the installed module inside.

Wiring and Connections

Figure 1: Description of internal parts of the product and module wire connections

The diagram shows the module's connections:

Connection Diagram Description:

Table 1: Module Wires

Wire Value Function
Red +12V Power for the detector
Black GND Common wire
White INP Alarm input
Blue TMP Tamper input
Yellow TRB Fault input

Technical Specifications

Specification Value
Power supply From the control panel bus 12 V DC (9...15 V)
Quiescent current consumption 8 mA (+ consumption of connected devices) all inputs connected to GND
Maximum current consumption 12 mA (+ consumption of connected devices)
Maximum permissible current of the connected detector 50 mA
Control panel device type (ACE) Type B
Dimensions 16 x 30 x 12 mm
Weight 8 g
Classification Security class 2 / Environmental class II (according to EN 50131-1)
Note: Valid only when built into a certified enclosure of security class 2 or higher.
Environment General indoor premises
Operating temperature range -10 °C to +40 °C
Relative humidity 75% relative humidity, non-condensing
Certifying bodies Trezor Test sro (No. 3025), Kiwa Nederland bv
Conforms to EN 50130-4, EN 55032, T 031, EN 50131-1, -3, EN IEC 63000

Compliance and Declarations

JABLOTRON a.s. hereby declares that the JA-111H TRB product complies with the relevant harmonized Union legislation: Directives No. 2014/30/EU, 2011/65/EU. The original Declaration of Conformity can be found on the website www.jablotron.com – Downloads section.

Logos: CE, UKCA

Note on Disposal: Proper disposal of this product helps conserve valuable resources and prevent any potential negative impact on human health and the environment that could result from improper waste handling. Please return the product to your dealer or contact your local authorities for more information on the nearest collection point.

To obtain an electronic version of this document (available in other languages) or an installation version for JA-100+, scan the attached QR code.

(QR code excluded as per instructions)

PDF preview unavailable. Download the PDF instead.

ja-111h-trb leg uk from en origin mln20207 Adobe PDF Library 25.1.97

Related Documents

Preview JABLOTRON JA-111H TRB Wired Detector Interface Bus Module - Installation and Specifications
Detailed installation guide and technical specifications for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors. Learn about connections, power, and compliance.
Preview JABLOTRON JA-111H TRB Bus Module: Installation and Technical Specifications
Comprehensive guide to the JABLOTRON JA-111H TRB bus module, detailing installation procedures, wiring diagrams, technical specifications, and compliance information for wired detector integration into JABLOTRON alarm systems.
Preview JABLOTRON JA-111H TRB Bus Module: Installation and Specifications
Comprehensive guide to the JABLOTRON JA-111H TRB bus module, detailing its installation, wiring, technical specifications, and compliance for wired alarm system detectors.
Preview JABLOTRON JA-111H TRB Bus Module - Installation and Technical Specifications
Comprehensive guide to the JABLOTRON JA-111H TRB bus module, covering installation, wiring, technical specifications, and compliance for wired alarm system detectors.
Preview JABLOTRON JA-111H TRB Busmodule: Installation and Technical Guide
Comprehensive guide to installing and configuring the JABLOTRON JA-111H TRB busmodule for wired detectors. Includes technical specifications, wiring diagrams, and compliance information.
Preview JABLOTRON JA-111H TRB Bus Module: Wired Detector Interface
Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. Includes wiring details, technical data, and compliance information.
Preview JA-111H TRB Bus Module – Interface for Wired Detectors
Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. It details installation steps, wiring, and product features.
Preview JABLOTRON JA-111H TRB Bus Module - Wired Detector Interface
Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. Learn about wiring, functions, and technical data.