JABLOTRON JA-111H TRB Bus Module

JABLOTRON JA-111H TRB Bus Module

Interface for Wired Detectors

Brand: JABLOTRON

Introduction

The JA-111H TRB module is a component of the JABLOTRON system. It serves to connect a wired detector with NO/NC outputs to the control panel bus. It provides power to the detector and reports its activation, tamper, and fault status. The module must be installed by a trained technician with a valid certificate issued by an authorized distributor.

Installation

Always disconnect power before connecting the module to the system bus.

The connected detector's power consumption must not exceed 50 mA (the module's power output has no overload protection).

It is designed for installation inside a standard wired detector (with contact outputs), but thanks to extended wires, it can also be installed outside it, in a protected installation box.

  1. Install the module in a suitable location within the detector or inside a protected installation box near the detector. The wire can be extended up to a maximum of 3 m. When installing the module inside the detector, ensure it cannot cause a short circuit due to inadequate insulation.
  2. Connect the wires to the detector (as per Figure 1).
  3. Connect the bus cable and power up the control panel.
  4. The control panel must be in service mode.
  5. Close the detector cover with the module installed inside.

Figure 1: Module internal parts and wiring connections

Description: Bus terminals (1), production code (2), yellow LED indicates fault/unregistered device, red LED indicates input activation by flashing (3), module wires (4). See table below.

Wire Meaning Function
Red +12V Power for detector
Black Ground Common wire
White INP Alarm input
Blue TMP Tamper input
Yellow TRB Trouble input

System Integration and Configuration

According to the control panel type, use the recommended software or application – consult the control panel manual.

Technical Specifications

Power 12 V DC bus (9...15 V) from the control panel bus
Quiescent current 8 mA (+ consumption of connected devices)
Max current 12 mA (+ consumption of connected devices)
Max permitted current for connected detector 50 mA
Detector control type (ACE) Type B
Dimensions 16 x 30 x 12 mm
Weight 8 g
Classification Security grade 2 / Environmental class II (according to EN 50131-1). Note: Valid only if incorporated in a certified enclosure of security grade 2 or higher.
Environment Indoor general
Operating temperature range -10 °C to +40 °C
Humidity 75% RH, non-condensing
Certification bodies Trezor Test sro (No. 3025), Kiwa Nederland bv
Conformity EN 50130-4, EN 55032, T 031, EN 50131-1, -3, EN IEC 63000

Compliance

JABLOTRON a.s. hereby declares that the product JA-111H TRB is in compliance with the applicable Union harmonisation legislation: Directives No. 2014/30/EU, 2011/65/EU. The original of the conformity assessment can be found at www.jablotron.com – Downloads Section.

Compliance marks: CE [European Conformity], UKCA [UK Conformity Assessed]

Disposal Information

Correct disposal of this product helps to save valuable resources and prevent possible negative effects on human health and the environment, which could arise from improper waste handling. Return the product to the reseller or contact the local authority for more information on the nearest designated collection point.

PDF preview unavailable. Download the PDF instead.

ja-111h-trb leg pt from en origin mln20207 Adobe PDF Library 25.1.97

Related Documents

Preview JABLOTRON JA-111H TRB Wired Detector Interface Bus Module - Installation and Specifications
Detailed installation guide and technical specifications for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors. Learn about connections, power, and compliance.
Preview JABLOTRON JA-111H TRB Bus Module: Installation and Technical Specifications
Comprehensive guide to the JABLOTRON JA-111H TRB bus module, detailing its function as an interface for wired detectors, installation instructions, wiring diagrams, technical specifications, and compliance information.
Preview JABLOTRON JA-111H TRB Bus Module: Installation and Specifications
Comprehensive guide to the JABLOTRON JA-111H TRB bus module, detailing its installation, wiring, technical specifications, and compliance for wired alarm system detectors.
Preview JA-111H TRB Bus Module – Interface for Wired Detectors
Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. It details installation steps, wiring, and product features.
Preview JABLOTRON JA-111H TRB Bus Module: Wired Detector Interface
Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. Includes wiring details, technical data, and compliance information.
Preview JABLOTRON JA-111H TRB Busmodule: Installation and Technical Guide
Comprehensive guide to installing and configuring the JABLOTRON JA-111H TRB busmodule for wired detectors. Includes technical specifications, wiring diagrams, and compliance information.
Preview JABLOTRON JA-111H TRB Bus Module: Installation and Technical Specifications
Comprehensive guide to the JABLOTRON JA-111H TRB bus module, detailing installation procedures, wiring diagrams, technical specifications, and compliance information for wired detector integration into JABLOTRON alarm systems.
Preview JABLOTRON JA-111H TRB Bus Module - Wired Detector Interface
Technical specifications and installation guide for the JABLOTRON JA-111H TRB bus module, an interface for wired detectors in JABLOTRON alarm systems. Learn about wiring, functions, and technical data.