Briloner MAL 2485045 Lighting Fixture Installation Guide

Introduction

This document provides installation and safety instructions for the Briloner MAL 2485045 lighting fixture.

Please read these safety instructions carefully before installing or using this product. Keep this user manual for future reference.

Diagram Overview

The primary diagram illustrates the mounting and wiring of the MAL 2485045 lighting fixture. It shows the fixture base, ceiling mounting, and electrical connections.

Key visual elements include:

  • The fixture's main body and arms.
  • Mounting holes for ceiling attachment.
  • Wiring terminals clearly labeled: L (Phase), N (Neutral), and G (Earth/Ground). Note: Safety Class II means no connection to G is required or permitted.
  • A dimension indicator (≥ 8mm) likely referring to wire stripping length or terminal connection depth.
  • Symbols indicating warnings: a crossed-out garbage bin (♻️) for proper disposal, a caution symbol (⚠️) for electrical shock risk, an attention symbol (❗) for disconnecting power, a temperature warning (?) for hot parts, and a symbol for not looking directly into the light source.
  • The IP20 rating is indicated, signifying protection against solid objects larger than 12.5mm and no water protection.

The diagram also shows CE and UK CA markings.

Safety and Installation Instructions

  1. The lamps may only be installed by authorized and qualified technicians according the valid regulations for electrical installation.
  2. The manufacturer does not accept any responsibility for injuries or damage resulting from improper use of the light.
  3. Maintenance of the lights is limited to the surfaces. For electrical safety reasons, this product must not be cleaned with water or other liquids. Use only a dry, lint-free cloth for cleaning.
  4. ⚠️ Caution! Risk of electric shock. Before connecting to the mains, always check the entire light for possible damage. Never use the light if you notice any damage.
  5. ❗ Attention! Disconnect the mains cable from the power supply before assembling or disassembling. Switch off the earth leakage circuit breaker/automatic circuit breaker or unscrew the fuse. Turn the switches to "OFF".
  6. ❗ Caution! Before drilling the mounting holes, make sure that no gas, water or electricity pipes and wires can be drilled through or damaged in your chosen mounting location.
  7. When mounting, ensure that the attachment material is suitable for the subsurface and that this surface is capable of carrying the weight of the fixture. The manufacturer is not liable for improper installation of the item on the relevant subsurface.
  8. ♻️ The symbol of the crossed-out garbage can on the product or the packaging means that the product must not be disposed with ordinary household waste. At the end of its useful life, the product must be returned to a point of acceptance for the recycling of electric and electronic device. Please ask your local municipality for the point of acceptance. Disposing of this product in line with local regulations helps to mitigate the effects on the environment and health which might otherwise occur as a result of hazardous substances, combinations or components.
  9. ?️ Safety Class II. This light is specially insulated and must not be connected to an earthed conductor.
  10. ?️ Safety Class II. Take note that when switching on that the building site supply lines available have double or reinforced insulation up to the terminal connection area. The enclosed terminal box ensures that when the building site conductors with basic insulation have a maximum length of "80 mm".
  11. Description of the supply terminals: L = Phase N = Neutral conductor G = Earthed conductor. Protective covers and end covers for mains voltage control parts must always be mounted.
  12. Do not install the light on a damp or conductive subsurface. Please make sure that no cables get damaged during the installation work.
  13. ? Attention! During operation, lamp parts and illuminants can reach temperatures of more than 60°C. Do not touch during operation!
  14. The lights have a protection class rating of "IP20" and are solely intended for indoor use only of private households.
  15. The maximum wattage indicated of each lighting unit must not be exceeded. Make sure that illuminants are securely fixed during the installation.
  16. Please make sure that illuminants have first cooled down before replacing them. ❗ Attention! Switch the mains power line to zero potential and switch-off the circuit breaker and/or remove the fuse before!
  17. Do not look directly into the light source (illuminant, LED, etc.).
  18. ? The included or insertable light bulb can be replaced by the end customer.
  19. This product can be used with light bulbs of the energy efficiency classes "A - G", based on the EU regulation 2019/2015.

Customer Service

For customer service, contact Briloner Leuchten GmbH & Co. KG at 00800/BRILONER (00800/27456637) or visit their address: Am Steinbach 14 / D-59872 Meschede.

Models: MAL-2485045 Spot Met Wood Smoked Glass, MAL-2485045, Spot Met Wood Smoked Glass, Wood Smoked Glass, Smoked Glass

File Info : application/pdf, 6 Pages, 653.03KB

PDF preview unavailable. Download the PDF instead.

original Microsoft Word für Microsoft 365

Related Documents

Preview MAL 3362-116 LED Ceiling Light with Motion Detector - Installation Guide
Installation and safety instructions for the Briloner MAL 3362-116 LED ceiling light with integrated motion detector. Features IP44 rating, adjustable sensitivity, time delay, and lux level for indoor use.
Preview Briloner MAL 3754 LED Light Fixture: Installation, Operation, and Safety Guide
Detailed user manual for the Briloner MAL 3754 LED light fixture, covering installation, safety precautions, remote control functions, troubleshooting, and compliance information.
Preview Briloner MAL 769401x LED Lamp Installation and Safety Guide
Installation and safety guide for the Briloner MAL 769401x LED lamp, detailing mounting steps, remote control functions, and essential safety precautions for indoor use.
Preview MAL 7157 Light Fixture Installation Guide
Provides essential safety instructions and step-by-step mounting guidance for the Briloner MAL 7157 light fixture. Learn how to safely install your luminaire indoors.
Preview Briloner MAL 3545 LED Light Installation Guide
Detailed installation instructions and safety guidelines for the Briloner MAL 3545 LED light fixture. Covers mounting steps, electrical connections, safety precautions, and product features like the integrated 3-step dimmer and memory function. Suitable for indoor domestic use.
Preview Briloner MAL 7304 LED Panel Light Installation and Operation Guide
Comprehensive installation and operation guide for the Briloner MAL 7304 LED panel light, covering safety, mounting, and remote control functions. Includes step-by-step instructions and safety warnings.
Preview Briloner Under-Cabinet LED Light - Assembly, Safety, and Operating Instructions
Comprehensive guide for the Briloner Under-Cabinet LED Light (Model 14137306L), covering assembly, safe operation, maintenance, and technical specifications. Ensure proper installation and usage.
Preview Briloner LED Ceiling Light - Dimmable, White Change, Timer, Night Light
Explore the Briloner LED ceiling light featuring adjustable white color temperature (3000K-6500K), dimmable functionality via remote control, integrated timer, and a convenient night light mode. This IP54 rated fixture offers a 5-year warranty and is available in Matt Chrome and Satin Chrome finishes.