Teleco Radio Receiver 12/24 VAC/DC
Model Numbers: TVRCM868A01, TVRCM868A02, TVRCM916A01, TVRCM916A02
Manufacturer: TELECO AUTOMATION SRL
Contact: Via dell'Artigianato, 16 - 31014 Colle Umberto (TV) ITALY | Tel: ++39.0438.388511 | Fax: ++39.0438.388536 | www.telecoautomation.com
CE Certification
Product Description
This is a compact 12/24 VAC/DC radio receiver with 2 potential-free outputs for controlling automated devices. It features a pulse function and has a protection rating of IP54.
Available Models:
- 1 Channel: TVRCM868A01 (868.3MHz), TVRCM916A01 (916MHz)
- 2 Channels: TVRCM868A02 (868.3MHz), TVRCM916A02 (916MHz)
Installation and Wiring
Mounting: The receiver is designed for easy mounting within a compact container.
Wiring Diagram:
The diagram shows connections for:
- Power Input: 12/24 Vac/dc
- Outputs: OUT1, OUT2
- Antenna Connection
The diagram indicates that the J3 terminal can be set for 12V ac/dc (ON) or 24V ac/dc (OFF).
Radio Code Memorization
CH1 (OUT1)
To memorize a code: Press and hold button P1 on the transmitter, then press and hold button P1 on the receiver. Press the transmitter button corresponding to the code to be memorized. A continuous sound indicates successful memorization.
CH2 (OUT2)
To memorize a code: Press P1 twice and keep it pressed on the receiver. Then, press the transmitter button corresponding to the code to be memorized. A continuous sound indicates successful memorization.
Radio Code Deletion
Single Radio Code Deletion (using P2)
To delete a single code: Press and hold button P2 on the receiver. Press the transmitter button corresponding to the code to be deleted. An intermittent sound indicates successful deletion.
All Radio Codes Deletion (using P2)
To delete all codes: Press P2 twice and keep it pressed for 10 seconds on the receiver. An intermittent sound indicates that all codes have been deleted.
Remote Memorization of Further Radio Codes (using P3)
Procedure: The P3 button is located inside the transmitter. To add a new code, press button P3 of the memorized transmitter, then press the button for a memorized code, and finally press the button for the new code. This procedure is compatible with any transmitter type.
Remote Deletion of a Radio Code (using P3)
Procedure: The P3 button is located inside the transmitter. To delete a code, press button P3 of the memorized transmitter three times. Then, press the button corresponding to the code to be deleted. A continuous sound indicates successful deletion.
Technical Specifications
Feature | Specification |
---|---|
Power Supply | 12/24 Vac/dc |
Max. Commutable Power at Relay | 1A |
Operating Temperature Range | -20°C to +50°C |
Protection Rating | IP54 |
Reception Frequency | 868.3 MHz (TVRCM868A01-02) 916 MHz (TVRCM916A01-02) |
Radio Memory Capability (Transmitters) | 42 |
Dimensions (W x H x D) | 90 x 60 x 26 (mm) |
Important Warnings and Compliance
General Warnings: Read instructions carefully before installation and use. Keep instructions for future reference. Installation and maintenance should only be performed by qualified personnel, adhering to current electrical regulations. The manufacturer is not liable for damages resulting from incorrect installation or improper use.
EU Declaration of Conformity: Teleco Automation s.r.l. declares that this radio equipment complies with Directive 2014/53/EU. The full text of the EU compliance declaration is available at: www.telecoautomation.com/ce.
WEEE Information: The crossed-out wheelie bin symbol indicates that the product must be collected separately at the end of its life. Contact local authorities for disposal information. Proper disposal and recycling help prevent negative environmental and health effects.
Product Development: The manufacturer reserves the right to change technical data and features without prior notice as part of continuous product development.