Lithonia Lighting 2BLT2R Series: Volumetric Recessed Lighting 2'x2' Relight
Digital Navigation: Ordering Tree, nLight Platform, SensorSwitch JOT, Photometrics, Performance Data
Features & Specifications
INTENDED USE: The BLTR Best-Value Low Profile LED Relight Assembly is a cost-effective solution for renovating existing fluorescent troffer and parabolic fixtures, offering upgraded aesthetics and outstanding performance. Its popular center basket design provides a clean, versatile style and volumetric distribution. A wide range of lumen packages and control and driver options make the BLTR suitable for offices, schools, hospitals, retail spaces, and other general lighting applications. Note: Certain airborne contaminants can diminish the integrity of acrylic. Refer to the Acrylic Environmental Compatibility table for suitable uses.
CONSTRUCTION: Universal end brackets are constructed of 22-gauge powder-painted steel, secured with TEKS™ screws. The driver and light engine assembly are integrated into the BTLR door assembly for a simple, time-saving relight solution. The door frame and reflector assembly are made of cold-rolled steel, painted with a matte white powder paint for improved aesthetics and light diffusion. Diffusers are extruded from impact-modified acrylic for durability. Diffuser trim rings provide mounting for integral sensors and add decorative elements.
OPTICS: Volumetric illumination is achieved through an optimal mix of light to walls, partitions, and vertical and horizontal work surfaces, creating a balanced luminous environment. High-performance extruded acrylic diffusers conceal LEDs and efficiently deliver light. Four diffuser choices are available: curved and square designs with linear prisms, or a smooth frosted finish.
ELECTRICAL: Long-life LEDs and high-efficiency drivers provide superior illumination quality and quantity for extended service life. Features 80% LED lumen maintenance at 60,000 hours (L80/60,000) and color variation within a 3-step MacAdam ellipse (3SDCM).
Non-Configurable BLTR Relight: Generic 0-10 volt dimming driver, dims to 10%.
Configurable BLTR Relight: Available in High Efficiency (HE) versions for lower wattage applications (>130 LPW). Specified via Lumen Package designations.
eldoLED driver options: Offer choice of dimming range and control, ensuring flicker-free operation, low current inrush, 89% efficiency, and low EMI.
Step-level dimming: Allows switching to 50% power to comply with energy codes while maintaining fixture appearance.
Optional integrated nLight controls: Make each luminaire addressable, enabling digital communication with other nLight controls (dimmers, switches, nLight AIR RIO, RES7 occupancy sensors, photo controls) via standard Cat-5 cabling. Features plug-and-play convenience with automatic device discovery and self-commissioning.
Lumen Management: Unique system (option N80) maintains constant lumen output over system life, preventing energy waste from over-lighting. Driver disconnect provided where required by US and Canadian codes.
SENSOR - Integrated sensor (individual control): SensorSwitch MSD7ADCX (PIR) or MSDPDT7ADCX (PIR/Microphonics Dual Tech) integrated occupancy sensor/automatic dimming photocell powers off the luminaire when the space is unoccupied or has sufficient ambient light. See page 4 for details.
Integrated Sensor (nLight Wired Networking): nLight-enabled sensor communicates over an nLight network. When wired with other nLight-enabled devices using CAT-5 cabling, an nLight control zone is created. Remote status monitoring and control via SensorView software is possible when linked to a Gateway.
Integrated Smart Sensor (nLight Air Wireless Platform): rES7 sensor communicates over the wireless nLight control platform. Available with automatic dimming photocell and either a digital PIR or microphonics (PDT) dual technology occupancy sensor. Pairs with other luminaires and wall switches via the CLAIRITY™ mobile app for simple sensor adjustment. See page 6 for details.
Integrated Wireless Sensor (single room control): SensorSwitch VERTEX JOT or JOTVTX15 luminaire-embedded occupancy and ambient light sensor powers off the luminaire when the space is unoccupied or has sufficient ambient light. See page 4 for details.
INSTALLATION: After removing existing fluorescent components, universal end brackets are secured with TEKST™ screws. The BLTR's integrated driver and light engine door assembly hinges to the brackets for wiring. Rotate the doorframe closed and pivot cam latches to secure. Suitable for damp location installations (damp location not available with sensor versions).
LISTINGS: UL/cUL Listed for use in fluorescent light fixtures. Installing Relight assemblies per instructions will not impact existing fixture UL listing. Tested to LM80 standards. DesignLights Consortium® (DLC) Premium and DLC qualified product. Check DLC Qualified Products List for specific version qualifications.
BUY AMERICAN ACT: Product with BAA option is assembled in the USA and meets government procurement requirements. Refer to www.acuitybrands.com/buy-american for details.
WARRANTY: 5-year limited warranty. Refer to www.acuitybrands.com/support/warranty/terms-and-conditions for complete terms.
NOTE: Actual performance may differ based on end-user environment and application. Values are typical, measured under laboratory conditions at 25 °C. Specifications subject to change without notice.
COMMERCIAL INDOOR
Specifications
Length: 23.9 in (60.7 cm)
Width: 23.9 in (60.7 cm)
Depth: 2.75 in (6.9 cm)
Weight: 10 lbs (25.4 kg)
All dimensions are inches (centimeters) unless otherwise specified.
BLTR Relight Series - 2BLT2R
2' x 2' Relight LED
A+ Capable Luminaire: Designed and tested for consistent color appearance and out-of-the-box control compatibility with simple commissioning. Meets Acuity Brands' specifications for chromatic consistency.
A+ Certified Solution: Luminaire is part of an A+ Certified solution for nLight® control networks when ordered with drivers marked by a shaded background. Provides advanced control functionality at the luminaire level.
To learn more about A+, visit www.acuitybrands.com/aplus.
*See ordering tree for details.
Ordering Information
Lead times will vary depending on options selected. Consult with your sales representative.
Example: 2BLT2R 33L ADP EZ1 LP835
Series | Trim Type/Air Function | Lumens² | Diffuser | Voltage | Driver | Color temperature |
2BLT2R 2X2 | (blank) Standard white two-piece flanged bracket | 20L 2000 | ADP Curved, linear prisms | (blank) MVOLT | (blank) Standard efficiency (>125 LPW) | LP830 82CRI, 3000 K |
BLTR | A Standard two-piece flanged bracket painted black to match parabolic / air-handling reveals | 20LHE 2000 | ADSM Curved, smooth | 120 120V | EZ1 eldoLED dims to 1% (0-10 volt dimming) | LP835 82CRI, 3500 K |
F Flangeless two-piece bracket for installation in drywall / "hard lid" ceilings | 33L 3300 | SDP Square, linear prisms | 277 277V | GZ1 Dims to 1% (0-10V dimming) | LP840 82CRI, 4000 K | |
33LHE 3300 | SDSM Square, smooth | 347 347V⁴,⁵ | GZ10 Dims to 10% (0-10V dimming)⁶ | LP850 82CRI, 5000 K | ||
40L 4000 | ADPT Curved, linear prisms | SLD Step-level dimming⁷ | LP930 90CRI, 3000K | |||
40LHE 4000 | ADSMT Curved, smooth | EOHN On/Off (non-dim) | LP935 90CRI, 3500K | |||
48LHE 4800 | SDPT Square, linear prisms | LP940 90CRI, 4000K | ||||
SDSMT Square, smooth | LP950 90CRI, 5000K |
nLight Interface | Control ¹⁰ | Individual Control | Standby Mode Options | Options |
nLight Wired (blank) no nLight® interface | nLight Wired (blank) No sensor control | MSD7ADCX PIR integral occupancy sensor with automatic dimming control ¹² | NOC Occupancy sensor disabled ¹³ | EL7L 700 lumen battery pack |
N80 nLight with 80% lumen management | NES7 nLight™ nES 7 PIR integral occupancy sensor ¹¹ | MSDPDT7ADCX PDT integral occupancy sensor with automatic dimming control ¹² | EL14L 1400 lumen battery pack | |
N80EMG nLight with 80% lumen management. For use with generator supply EM power ⁸ | NES7ADCX nLight™ nES 7 ADCX PIR integral occupancy sensor with automatic dimming photocell ¹¹ | E10WLCP EM Self-Diagnostic battery pack, 10W Constant Power, Certified in CA Title 20 MAEDBS | ||
N100 nLight without lumen management | NESPDT7 nLight™ nES PDT 7 dual technology integral occupancy control ¹¹ | BGTD Bodine Generator Transfer Device ¹⁴ | ||
N100EMG nLight without lumen management. For use with generator supply EM power ⁸ | NESPDT7ADCX nLight™ nES PDT 7 dual technology integral occupancy sensor with automatic dimming photocell ¹¹ | GLR Fast-blowing fuse ¹⁵ | ||
nLight Wireless (blank) no nLight® interface | nLight Wireless RES7 nLight AIR control with PIR integral occupancy sensor and automatic dimming photocell ¹⁷ | GMF Slow-blowing fuse ¹⁵ | ||
NLTAIR2 nLight AIR Generation 2 enabled ⁹ | RES7PDT nLight AIR control with PDT dual technology integral occupancy sensor and automatic dimming photocell ¹⁷ | NPLT Narrow pallet | ||
RIO nLight AIR radio module without sensor ¹⁷ | FAO Field adjustable output ¹⁶ | |||
RES7EM nLight AIR PIR integral occupancy sensor with automatic dimming photocell and UL924 Emergency Operation, via power interrupt detection ¹⁷ | BAA Buy America(n) Act Compliant | |||
RES7PDTEM nLight AIR microphonics dual technology occupancy sensor with automatic dimming photocell and UL924 Emergency Operation, via power interrupt detection ¹⁷ | JP40 Job Pack | |||
RIOEM nLight AIR radio module less sensor, with UL924 Emergency Operation, via power interrupt detection ¹⁷ |
Notes:
- ¹ Consult factory for airflow data.
- ² Approximate lumen output.
- ³ All versions may not achieve 130+ LPW. Refer to photometry on www.acuitybrands.com.
- ⁴ Not available with EL7L or EL14L battery packs.
- ⁵ 347 not available with SLD.
- ⁶ GZ1, GZ10 not available with any Control or Sensor options.
- ⁷ Not available with N80, N80EMG, N100, N100EMG, NLTAIR2, or occupancy control.
- ⁸ nLight EMG option requires a connection to existing nLight network. Power is provided from a separate N80 or N100 enabled fixture.
- ⁹ Must order with RES7, RES7PDT, or RIO sensor. Only available with EZ1 driver.
- ¹⁰ Must specify diffuser with trim rings. See sensor options on page 4.
- ¹¹ Requires N80, N80EMG, N100, or N100EMG.
- ¹² Only available with EZ1 driver option. 0-10v dimming wires not accessible via access plate. Not available with Controls options.
- ¹³ Can only be ordered in conjunction with EZ1, NLTAIR2, RES7/RES7PDT. Occupancy sensor disabled at factory but can be re-enabled upon commissioning.
- ¹⁴ Requires BSE labeling. Consult factory for options.
- ¹⁵ Must specify voltage, 120 or 277 with GLR & GMF fusing.
- ¹⁶ Consult factory.
- ¹⁷ See UL924 Sequence of Operation instruction on page 3. When combined with the EZ1 option, can be used as a normal power sensing device for nLight AIR devices and luminaires with EM emergency options.
- ¹⁸ Wired 0-10v dimming control not available. Not available with nLight Interface or Controls options. Not available with SLD, NOC, BGTD, or FAO. Must specify diffuser with trim rings.
Multiple Diffuser Options
ADP Curved Ribbed
ADSM Curved Smooth
SDP Square Ribbed
SDSM Square Smooth
Non-Configurable BLTR
Stock | Catalog Description* | UPC | Lumens | Wattage | LPW | Color Temperature | Voltage | Pallet Qty |
2BLT2R 33L ADP LP835 | 190887550900 | 3313 | 27 | 124 | 3500K/80 CRI | 120-277 | 52 | |
2BLT2R 33L ADP LP840 | 190887550931 | 3404 | 27 | 127 | 4000K/80 CRI | 120-277 | 52 |
UL924 Sequence of Operation
This information applies to all nLight AIR devices with an EM option.
EM devices remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds.
Using the CLAIRITY+ mobile app, EM devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts.
Only non-emergency rPP20, rLSXR, rSBOR, rSDGR, and nLight AIR luminaires with version 3.4 or later firmware can provide normal power sensing for EM devices. Refer to specification sheets for control devices and luminaires for more information on options that support normal power sensing.
Accessories & Replacement Parts
Replacement Parts: Order as separate catalog number.
- DBLTR24 ADP LENS ASSEMBLY - 2 ft. replacement lens (trims included)
- DBLTR24 SDP LENS ASSEMBLY - 2 ft. replacement lens (trims included)
- DBLTR24 ADSM LENS ASSEMBLY - 2 ft. replacement lens (trims included)
- DBLTR24 SDSM LENS ASSEMBLY - 2 ft. replacement lens (trims included)
- DBLTR24 ADPT LENS ASSEMBLY - 2 ft. replacement lens (trims included)
- DBLTR24 SDPT LENS ASSEMBLY - 2 ft. replacement lens (trims included)
- DBLTR24 ADSMT LENS ASSEMBLY - 2 ft. replacement lens (trims included)
- DBLTR24 SDSMT LENS ASSEMBLY - 2 ft. replacement lens (trims included)
- DBLTR24 ADPT SENSOR LENS ASSEMBLY - 2 ft. replacement lens (trims included)
- DBLTR24 SDPT SENSOR LENS ASSEMBLY - 2 ft. replacement lens (trims included)
- DBLTR24 ADSMT SENSOR LENS ASSEMBLY - 2 ft. replacement lens (trims included)
- DBLTR24 SDSMT SENSOR LENS ASSEMBLY - 2 ft. replacement lens (trims included)
- U10528B - 2 ft. replacement troffer trim strip
Fit & Compatibility
The 2BLT2R Relight Assembly is designed to upgrade recessed 2x2 fixtures, including most parabolic and lensed troffers from all major manufacturers. Dimensional requirements are below, but Lithonia Lighting recommends a trial installation prior to purchasing project quantities.
SIDE SECTION
Diagram showing side section dimensions:
- Top dimension: 3.0 in
- Inner dimension: 21.1 in
- Outer dimension: 24.0 in
- Bottom dimension: 22.2 in
- Overall dimension: 22.7 in
- Small dimension near top: 0.75 in
- Small dimension near top: 12.0 in
Emergency Battery Pack Options - Field Installable
Battery Model Number | Wattage | Runtime (Minutes) | Lumen Output* (@120 Lumens/Watt) | Other |
ILB CP07 2H A | 7W | 120 | 840 | Storm Shelter / 2 Hour Runtime |
ILB CP10 A | 10W | 90 | 1200 | |
ILBLP CP10 HE SD A | 10W | 90 | 1200 | Title 20, Self Diagnostic |
ILBLP CP15 HE SD A | 15W | 90 | 1800 | Title 20, Self Diagnostic |
ILB CP20 HE A | 20W | 90 | 2400 | Title 20 |
ILB CP20 HE SD A | 20W | 90 | 2400 | Title 20, Self Diagnostic |
*Minimum delivered lumen output to assist in product selection for increased fixture mounting height.
The CP10 delivered emergency illumination outperforms legacy 1400 lumen fluorescent emergency ballast.
Please contact productsupportemergency@acuitybrands.com for any Emergency Battery related questions.
Application Guide
2BLT2R: Typically used for lensed troffer installations. Assembly contains white end brackets and is supplied with white trim strips for use in closing gaps down fixture sides (installer's choice - not required). *Note: This kit will fit in Lithonia's Avante non-air fixture.
2BLT2R A: Typically used for parabolic installations with black reveal. Assembly contains black end brackets to match black reveal around host housing. Does not interfere with host housing air supply/return if present (along fixture sides).
JOT Wireless
SensorSwitch JOT Enabled Wireless Solution
Designed with contractors in mind, the SensorSwitch JOT enabled wireless solution offers a straightforward approach to the installation and pairing of lighting fixtures and controls. Absolutely no 0-10V control wires and no mobile apps are needed with JOT enabled products, allowing for lightning speed installation right out of the box.
- Power: Install JOT enabled fixtures and controls as instructed.
- Pair: Insert the pairing tool into the pinhole on the wall switch; press and hold any button for 6 seconds.
- Play: Once paired, each fixture will individually dim down to 10% brightness. All products will be fully functional.
BLTR Series with integrated JOT OCC Sensors
SensorSwitch WSXA JOT
SensorSwitch SPODMRA JOT
nLight Platform
nLight embedded fixtures offer:
- Manual Dimming
- Motion Sensing and/or Daylight Harvesting
- Fixture or Group Level Control
- Flexibility
- Wireless Wall Switch (nLight AIR Only)
- Astronomical and Time of Day Scheduling
- Scalable Solution
- Future-Ready
Customers get:
- Convenience and visual comfort for occupants
- Energy savings and code compliance
- Ability to configure lighting to the space requirements
- Ease of fixture moves, adds and changes
- Ease and flexibility of placement
- Energy savings and building security
- nLight controls to grow with your business
- nLight platform to set foundation for future upgrades and capabilities
nLight Air Wireless
Simple as 1,2,3
- Install the nLight® AIR fixtures with embedded smart sensor.
- Install the wireless battery-powered wall switch.
- With CLAIRITY app, pair the fixtures with the wall switch and, if desired, customize the sensor settings for the desired outcome.
Diagram showing nLight Air Wireless setup with BLTR Series, nLight AIR rPODBA, and Mobile Device.
nLight Wired Networking
Simple as 1,2,3
- Install the nLight® Wired fixtures with embedded control.
- Install the nLight Wired wall switch.
- Connect the fixtures using standard CAT5e cables, and the devices will automatically discover each other and work (plug and play).
Diagram showing nLight Wired Networking setup with BLTR Series, nLight Wired nPODMA, and CAT5e cable.
Sensor Options
Option | Automatic Dimming Photocell | Occupancy Sensing PIR | Occupancy Sensing PDT | nLight Wired Networking | nLight AIR Networking |
MSD7ADCX | X | X | |||
MSDPDT7ADCX | X | X | |||
NES7 | X | X | |||
NES7ADCX | X | X | X | ||
NESPDT7 | X | X | X | ||
NESPDT7ADCX | X | X | X | X | |
RES7 | X | X | |||
RESPDT7 | X | X | X |
Sensor Coverage Pattern - Mini 360° Lens
Recommended for walking motion detection from mounting heights between 8 ft (2.44 m) and 20 ft (6.10 m).
- Initial detection of walking motion along sensor axes at distances of 2x the mounting height up to 15 ft (4.57 m) and 1.75x up to 20 ft (6.10 m).
- Provides 12 ft (3.66 m) radial detection of small motion when mounted at 9 ft (2.74 m).
- Initial detection will occur earlier when walking across sensor's field of view than when walking directly at sensor.
9 FT Mounting
Diagram showing sensor coverage pattern at 9 ft mounting height, with radial distances indicated in feet and meters.
Integrated Sensor with Individual Control
The MSD7ADCX PIR occupancy sensor/automatic dimming photocell is ideal for areas without obstructions and where daylight harvesting may be desired. Suggested applications include hallways, corridors, storage rooms, and breakrooms where people are typically moving.
The MSDPDT7ADCX PIR/Microphonics Dual Tech occupancy sensor/automatic dimming photocell is ideal for areas with obstructions and where daylight harvesting is desired. Suggested applications include open offices, private offices, classrooms, public restrooms, and conference rooms.
nLight AIR Wireless
nLight AIR is the ideal solution for retrofit or new construction spaces where adding additional wiring can be labor-intensive. nLight AIR is available with or without an integral sensor. The integrated rES7 or rES7PDT smart sensors are part of each luminaire in the nLight AIR network, which can be grouped to control multiple luminaires. The granularity of control with the digital PIR occupancy detection and daylight sensing makes it a great solution for any application.
nLight Wired Networking
The nES 7 is ideal for small rooms without obstructions or areas with primarily walking motion. Ideal areas include hallways, corridors, storage rooms, and breakrooms. Additionally, the nES7ADCX includes an integrated photocell, which enables daylight harvesting controls.
For areas like restrooms, private offices, open offices, conference rooms, or any space with obstructions, the nES PDT 7 dual technology sensor is recommended. The nES PDT 7 utilizes both PIR (passive infrared) and Microphonics technologies to detect occupancy. Additionally, the nESPDT7ADCX includes an integrated photocell, which enables daylight harvesting controls, ideal for areas where windows are present.
Sequence of Operation (MSD7 Sensor)
Diagram showing sequence of operation for MSD7 sensor: MAX LIGHT LEVEL, Occupants Detected In The Space, Room Unoccupied, MIN LIGHT LEVEL, LIGHTS ON, TIME DELAY, LIGHTS OFF.
*The presetting on the automatic dimming photocell is 5fc.
Sequence of Operation (nES7 and rES7 and Sensor)
Diagram showing sequence of operation for nES7 and rES7 sensors: MAX LIGHT LEVEL, Sensor Detects Motion, Occupants Detected In The Space, Room Unoccupied, MIN LIGHT LEVEL, LIGHTS ON, TIME DELAY, LIGHTS OFF.
*The presetting on the automatic dimming photocell is 5fc (NES7) and 10fc (RES7).
Controls Accessories
nLight® Wired Control Accessories:
Order as separate catalog number. Visit www.acuitybrands.com/products/controls/nlight.
WallPod stations
- On/Off - Model number: nPODMA [Color]
- On/Off & raise/lower - Model number: nPODMA DX [Color]
- Graphic touchscreen - Model number: nPOD TOUCH [Color]
- Photocell controls - Model number: nCM ADCX RJB
- Full range dimming - Model number: nCM 9 RJB/nCM PDT 9 RJB
Occupancy sensors
- Small motion 360°, ceiling (PIR / dual tech) - Model number: nCM10 RJB/nCM PDT 10 RJB
- Large motion 360°, ceiling (PIR / dual tech) - Model number: nWSX PDT LV DX [color]
Other
- Wall switch with raise/lower - Model number: CAT5 10FT J1
- Cat-5 cable (plenum rated) - Model number: CAT5 30FT J1
nLight® AIR Control Accessories:
Order as separate catalog number. Visit www.acuitybrands.com/products/controls/nlightair.
Wall switches
- On/Off single pole - Model number: rPODBA [color] G2
- On/Off two pole - Model number: rPODBA2P [color] G2
- On/Off & raise/lower single pole - Model number: rPODBA DX [color] G2
- On/Off & raise/lower two pole - Model number: rPODBA 2P DX [color] G2
Diagram illustrating nLight wired and wireless control setup with BLTR fixtures, sensors, and wall controls.
rCMS¹
Series / Detection | Power Supply¹ | Occupancy Detection | Lens (Required) | Operating Mode | Generation |
RCMS nLight AIR occupancy and daylight sensor | [blank] Power Supply ordered separately | PIR | 10 Large Motion/ Extended Range 360° | [BLANK] None | Generation 2 compatibility |
PS 150 Standard 150 mA Power Supply | PDT Dual Tech PIR/ Microphonics | 9 Small Motion/Extended Range 360° | AR Auxiliary Relay | ||
6 High Bay 360° Lens | On/Off |
Notes:
¹ RCMS requires low voltage power from either RPP20 DS 24V G2 or PS150.
Diagrams showing various sensors and controls: SensorSwitch WSX, nLight WIRED nPOD UNITOUCH, nLight WIRED nPODMA DX, nLight AIR rPODBA, BLTR with rIO, rPODBA, RCMS.
Constant Lumen Management
Enabled by the embedded nLight control, the BLTR actively tracks its run-time and manages its light source to maintain constant lumen output over the system life. This feature eliminates the energy waste created by the traditional practice of over-lighting.
Without Lumen Management: Energy is wasted and light level is inconsistent.
Diagram showing wasted energy over operating hours.
With Lumen Management: Energy is saved and light level remains consistent.
Diagram showing saved energy over operating hours.
PHOTOMETRICS
2BLT2R 33L ADP LP835, 3241 delivered lumens
Diagram showing photometric data (polar curve) and tables for Coefficients of Utilization and Zonal Lumen Summary.
2BLT2R 40L ADP LP835, 4210 delivered lumens
Diagram showing photometric data (polar curve) and tables for Coefficients of Utilization and Zonal Lumen Summary.
FAO SETTINGS (Field Adjustable Output)
0-10 Voltage Dimmer | % Lumen Output (approximate) | % Wattage (approximate) |
Step 8 Full Output | 100% | 100% |
Step 7 9.0 VDC | 98% | 100% |
Step 6 8.0 VDC | 88% | 86% |
Step 5 7.0 VDC | 86% | 82% |
Step 4 6.0 VDC | 82% | 80% |
Step 3 5.0 VDC | 76% | 75% |
Step 2 4.0 VDC | 71% | 72% |
Step 1 3.0 VDC | 67% | 71% |
Simple adjustment of output through the use of a flat head screwdriver.
Performance Data
Lumen Package
Lumen Package | Lumens | Input Watts | LPW |
20L ADP LP830 | 1981 | 16 | 127 |
20L ADP LP835 | 2051 | 16 | 132 |
20L ADP LP840 | 2084 | 16 | 134 |
20L ADP LP850 | 2143 | 16 | 138 |
33L ADP LP830 | 3237 | 26 | 125 |
33L ADP LP835 | 3351 | 26 | 130 |
33L ADP LP840 | 3404 | 26 | 132 |
33L ADP LP850 | 3502 | 26 | 135 |
40L ADP LP830 | 3900 | 31 | 125 |
40L ADP LP835 | 4038 | 31 | 130 |
40L ADP LP840 | 4102 | 31 | 132 |
40L ADP LP850 | 4220 | 31 | 136 |
HE Performance Data
Lumen Package | Lumens | Input Watts | LPW |
20LHE ADP LP830 | 2008 | 16 | 129 |
20LHE ADP LP835 | 2079 | 16 | 134 |
20LHE ADP LP840 | 2112 | 16 | 136 |
20LHE ADP LP850 | 2173 | 16 | 140 |
33LHE ADP LP830 | 3068 | 24 | 128 |
33LHE ADP LP835 | 3176 | 24 | 133 |
33LHE ADP LP840 | 3227 | 24 | 135 |
33LHE ADP LP850 | 3319 | 24 | 139 |
40LHE ADP LP830 | 3797 | 29 | 129 |
40LHE ADP LP835 | 3931 | 29 | 133 |
40LHE ADP LP840 | 3994 | 29 | 135 |
40LHE ADP LP850 | 4108 | 29 | 139 |
48LHE ADP LP830 | 4532 | 36 | 126 |
48LHE ADP LP835 | 4692 | 36 | 130 |
48LHE ADP LP840 | 4767 | 36 | 132 |
48LHE ADP LP850 | 4903 | 36 | 136 |