Lithonia 2BLT Series 2'x4' Volumetric Recessed LED Luminaire

Catalog Number: DIGITAL NAVIGATION

Model: 2BLT4

Features & Specifications ⚙️

Intended Use ?

The BLT Best-in-Value Low Profile LED luminaire features a popular center basket design offering a clean, versatile style and volumetric distribution. High efficacy LED light engines deliver energy savings and low maintenance compared to traditional sources. An extensive selection of configurations and options make the BLT the perfect choice for many lighting applications including schools, offices, commercial spaces, retail, hospitals, and healthcare facilities. The low profile BLT design (2-3/8" deep) also makes it an excellent choice for renovation projects.

Construction ?️

Components are coated with a proprietary paint blend and die-formed for dimensional consistency. The reflector is available in smooth or ribbed finishes (RB option). End plates contain integral T-bar clips for secure attachment to T-grid ceilings; optional screw-on T-bar clips are available for added security. Diffusers are extruded from impact-modified acrylic for increased durability. LED boards and drivers are accessible from the plenum.

Optics ?

Volumetric illumination is achieved by creating an optimal mix of light to walls, partitions, and vertical/horizontal work surfaces, rendering the interior space, objects, and occupants in a balanced luminous environment. A typically configured 2BLT4 features a Unified Glare Rating (UGR) starting at 17 (UGR data available on page 8). High-performance extruded acrylic diffusers conceal LEDs and efficiently deliver light in a volumetric distribution. Five diffuser choices are available: curved and square designs with ribbed or smooth frosted finishes.

Electrical ⚡

Long-life LEDs coupled with high-efficiency drivers provide superior illumination for extended service life. Features 80% LED lumen maintenance at 60,000 hours (L80/60,000) and color variation within a 3-step MacAdam ellipse (3SDCM).

  • Non-Configurable BLT: Generic 0-10 volt dimming driver (dims to 10%).
  • Configurable BLT: Available in High Efficiency (HE) versions for lower wattage applications (>130 LPW), specified via Lumen Package designations.
  • eldoLED driver options: Offer choice of dimming range and control, assuring flicker-free operation, low-current inrush, 89% efficiency, and low EMI.
  • Optional integrated nLight® controls: Make each luminaire addressable, digitally communicating with other nLight-enabled controls (dimmers, switches, occupancy sensors, photocontrols). Connection is simple via integrated nLight AIR wireless RIO, RES7 sensors, or standard Cat-5 cabling. nLight offers plug-and-play convenience with automatic device discovery and self-commissioning. nLight AIR is commissioned via a mobile app.
  • Lumen Management (Option N80): A unique system providing on-board intelligence to actively manage the LED light source, maintaining constant lumen output over the system life and preventing over-lighting.
  • Step-level dimming: Allows system to be switched to 50% power for energy code compliance while maintaining fixture appearance.

Controls ?

  • Standalone Embedded Controls: Available with wired or wireless standalone embedded controls by SensorSwitch.
  • Networked Embedded Controls: Available with wired or wireless networked embedded controls by nLight®, addressing Luminaire Level Lighting Controls (LLLC) requirements.

Installation ?️

The BLT's low profile design (2-3/8" deep) provides installation flexibility, especially in restrictive plenum applications. Designed for use in NEMA standard Type G (1" & 15/16"), NFG (9/16"), and SS (9/16") grid ceilings. Consult factory for other ceiling types. Drywall Grid Adapters (DGA) are available as an accessory for recessed mounting in hard ceiling applications. Suitable for damp locations.

Listings ✅

CSA Certified to meet U.S. and Canadian standards. IC rated. Tested in accordance with ISO 14644-1; suitable for use in ISO 5-9 positive and negative pressure clean rooms. DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Check the DLC Qualified Products List at www.designlights.org/QPL for specific version qualifications.

Government Procurement ?️

BAA: Product with BAA option qualifies as a domestic end product under the Buy American Act and manufactured in the United States under DOT Buy America regulations. BABA: Build America Buy America: Product with BAA option qualifies as produced in the United States. Refer to www.acuitybrands.com/buy-american for additional information.

Warranty ?️

5-year limited warranty. This is the sole warranty provided; no other statements create any warranty. All other express and implied warranties are disclaimed. Complete warranty terms are located at: www.acuitybrands.com/support/warranty/terms-and-conditions.

? Notes: Actual performance may differ based on end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25°C. Specifications are subject to change without notice.

Dimensions ?

  • Length: 47-3/4" (121.2 cm)
  • Width: 23-3/4" (60.3 cm)
  • Depth: 2-3/8" (6.0 cm)
  • Static Depth with Air supply/return: 2-3/4" (6.9 cm)

All dimensions are in inches (centimeters) unless otherwise specified.

Acuity A+ Capable Luminaire

This luminaire is designed and tested to provide consistent color appearance and out-of-the-box control compatibility with Acuity Brands control products. All configurations are calibrated to meet Acuity Brands' specifications for chromatic consistency, including color rendering, color fidelity, and color temperature tolerance. Learn more about Acuity A+ standards at www.acuitybrands.com/aplus.

Ordering Information ?

Lead times vary by options selected. Consult your sales representative. Design Select options, indicated by a shaded background, ship in 15 days or less. Visit www.acuitybrands.com/designselect for details.

Fixture Style

  • (blank): Smooth Reflector
  • RB: Ribbed Reflector

Air Function

  • (blank): Static
  • A: Air supply/return

Lumens

Standard efficiency (>100 LPW): 30L (3000), 40L (4000), 48L (4800), 60L (6000), 72L (7200), 85L (8500), 100L (10000), 120L (12000)

High efficiency (>130 LPW): 30LHE (3000), 40LHE (4000), 48LHE (4800), 60LHE (6000), 72LHE (7200), 85LHE (8500)

Diffuser

  • ADP: Curved, ribbed
  • ADSM: Curved, smooth
  • SDP: Square, ribbed
  • SDSM: Square, smooth
  • LUGR: Low UGR lens (Includes trim rings to match sensored version)
  • ADPT: Curved, ribbed (with trim)
  • ADSMT: Curved, smooth (with trim)
  • SDPT: Square, ribbed (with trim)
  • SDSMT: Square, smooth (with trim)
  • LUGRT: Low UGR lens (with trim)

Voltage

  • (blank): MVOLT (120-277V)
  • 120: 120V
  • 277: 277V
  • 347: 347V

Driver

  • EZ1: eldoLED dims to 1% (0-10 volt dimming)
  • GZ1: Dims to 1% (0-10V dimming)
  • GZ10: Dims to 10% (0-10V dimming)
  • SLD: Step-level dimming

Color Temperature

  • LP830: 82CRI, 3000 K
  • LP835: 82CRI, 3500 K
  • LP840: 82CRI, 4000 K
  • LP850: 82CRI, 5000 K
  • LP930: 90CRI, 3000K
  • LP935: 90CRI, 3500K
  • LP940: 90CRI, 4000K
  • LP950: 90CRI, 5000K

nLight Interface

  • Wired:
  • (blank): No nLight interface
  • N80: nLight with 80% lumen management
  • N80EMG: nLight with 80% lumen management (for generator supply EM power)
  • N100: nLight without lumen management
  • N100EMG: nLight without lumen management (for generator supply EM power)
  • Wireless:
  • (blank): No nLight AIR interface
  • NLTAIR2: nLight AIR Generation 2 enabled

Control (nLight Wired)

  • (blank): No sensor control
  • NES7: nLight™ nES 7 PIR integral occupancy sensor
  • NESPDT7: nLight™ nES PDT 7 dual technology integral occupancy control
  • NES7ADCX: nLight™ nES 7 ADCX PIR integral occupancy sensor with automatic dimming photocell
  • NESPDT7ADCX: nLight™ nES PDT 7 dual technology integral occupancy sensor with automatic dimming photocell

Control (nLight Wireless)

  • RES7: nLight AIR control with PIR integral occupancy sensor
  • RES7PDT: nLight AIR control with PDT dual technology integral occupancy sensor
  • RIO: nLight AIR radio module without sensor
  • RES7EM: nLight AIR PIR integral occupancy sensor with automatic dimming photocell and UL924 Emergency Operation, via power interrupt detection
  • RES7PDTEM: nLight AIR PDT dual technology integral occupancy sensor with automatic dimming photocell and UL924 Emergency Operation, via power interrupt detection
  • RIOEM: nLight AIR radio module less sensor, with UL924 Emergency Operation, via power interrupt detection

Individual Control

  • MSD7ADCX: PIR integral occupancy sensor with automatic dimming control photocell
  • MSDPDT7ADCX: PDT integral occupancy sensor with automatic dimming control photocell
  • SSAIR: Wireless standalone embedded control by SensorSwitch
  • SSAIR VAPIR: Wireless standalone embedded control by SensorSwitch with Passive Infrared Occ sensor with autodimming photocell

Standby Mode

  • NOC: No Occupancy sensor disabled

Options

  • BDP: Disconnect Plug
  • EL7L: 700 lumen battery pack (Noncompliant with CA T20)
  • EL14L: 1400 lumen battery pack (Noncompliant with CA T20)
  • E10WLCP: EM Self-Diagnostic battery pack, 10W Constant Power, Certified in CA Title 20
  • E10WSTAR: Emergency battery pack, Enabled with STAR
  • CP: Chicago plenum
  • BGTD: Bodine Generator Transfer Device
  • PWS1836: 6' pre-wire, 3/8" diameter, 18 gauge, 1 circuit
  • PWS1846: 6' pre-wire, 3/8" diameter, 18 gauge, 2 circuit
  • PWS1846 PWSLV: Two cables: one 6' pre-wire, 3/8" diameter, 18 gauge, 2 circuits; one 6' pre-wire, 3/8" diameter, 18 gauge
  • PWS1856LV: 6' pre-wire, 3/8" diameter, 18 gauge, 1 circuit w/ low voltage wires
  • GLR: Fast-blowing fuse
  • GMF: Slow-blowing fuse
  • NPLT: Narrow pallet
  • RRL_: RELOC®-ready luminaire
  • LATC: Earthquake clip
  • WH: Glossy White
  • DWAM: Anti-Microbial paint
  • JP14: Job packaging
  • JP22: Job packaging
  • IP5X: Gasketed diffuser compartment to meet IP5X rating
  • BAA: Buy America(n) Act and/or Build America Buy America Qualified

Note: Options marked with ' ' have ordering restrictions. Refer to the Option Value Ordering Restrictions chart.

Option Value Ordering Restrictions

Option Value Restriction
347V Not available with SLD, EL7L, EL14L, or E10WLCP options.
A (Air Function) Not available with RB fixture style; consult factory for air flow data. If a job pack is selected, use JP14 only.
BGTD Not available with TD, SSAIR, SSAIR VAPIR sensor options or emergency battery options. Must specify voltage. Requires BSE labeling, voltage specific. Example: BGTD BSE10.
CP Must specify diffuser with trim rings.
E10WSTAR, E10WLCP, EL7L, EL14L Not available with N80, N80EMG, N100, N100EMG, PWS1836, PWS1846, PWS1846 PWSLV or PWS1856LV. Not compatible with 347V. When using pre-wire option, use PWS1846 or PWS1846 PWSLV. EZ1 driver required.
FAO Not available with USPOM, FAO or lumen packages > 6000LM. FAO restricts use of external Dimming controls. See chart on page 3 for additional details.
GLR, GMF Must specify voltage. 120 or 277, with GLR and GMF fusing.
IP5X Not available with air supply/return or Wired Networking (NES_) and Individual Control (MSD_) sensors.
LUGR, LUGRT Not available with standard efficiency 85L, 85LHE, 100L or 120L lumen options. Not available with SLD, nLight, NLTAIR2, NOC, or BGTD options. Only available on fixtures with NES7, NESPDT7, NESPDT7ADCX, MSD7ADCX, MSDPDT7ADCX, RES7, RES7PDT, RIO, SSAIR, SSAIR VAPIR. Not available when 'A' air supply/return function and sensor options are combined.
MSD7ADCX, MSDPDT7ADCX Not available with option: NES7, NESPDT7, NESPDT7ADCX, MSD7ADCX, MSDPDT7ADCX, RES7, RES7PDT, RIO, SSAIR, SSAIR VAPIR. Not available when 'A' air supply/return function option.
NES7, NESPDT7, NES7ADCX, NESPDT7ADCX Approximate lumen output. For high Efficiency, all versions may not achieve 130+ LPW. Refer to photometry on www.acuitybrands.com. Air supply/return option, 90 CRI, and versions with integral sensor trim rings may not achieve 130 LPW. Due to the unique optics used to drive the low UGR distribution, the LUGR lens is not uniformly lit and presents visible striping. Only available with EZ1 driver option. 0-10v dimming wires not accessible via access plate. Requires N80, N80EMG, N100, or N100EMG. Only available with EZ1 driver. Must order with nLight Wireless option from Control section. Not available with GZ10 driver. Not available with 85L, 85LHE, 100L, or 120L options. Can only be ordered in conjunction with EZ1 or GZ1, NLTAIR2, RES7/RES7PDT. Occupancy sensor disabled at factory but can be re-enabled upon commissioning. nLight EMG option requires a connection to existing nLight network. Power is provided from a separate N80 or N100 enabled fixture. Not available with nLIGHT wired network or individual controls. See UL 924 Sequence of Operation chart on page 3. When combined with the EZ1 option, can be used as a normal power sensing device for nLight AIR devices and luminaires with EM emergency options. See UL924 Sequence of Operation chart on page 3. Not available with 72L, 72LHE, 85L or 85LHE lumen packages. Not available with GZ10 or GZ1 driver. For ordering logic consult: RRL_2013. Not available with any nLight Interface or Control options.
NLTAIR2 Not available with GZ10 or GZ1 driver. For ordering logic consult: RRL_2013. Not available with any nLight Interface or Control options.
NOC Occupancy sensor disabled at factory but can be re-enabled upon commissioning.
N80EMG, N100EMG nLight EMG option requires a connection to existing nLight network. Power is provided from a separate N80 or N100 enabled fixture. Not available with nLIGHT wired network or individual controls. See UL 924 Sequence of Operation chart on page 3. When combined with the EZ1 option, can be used as a normal power sensing device for nLight AIR devices and luminaires with EM emergency options. See UL924 Sequence of Operation chart on page 3.
PWS1846, PWSLV, PWS1856LV When using pre-wire option, use PWS1846 or PWS1846 PWSLV.
RES7, RES7PDT, RIO, RES7EM, RES7PDTEM, RIOEM Not available with 72L, 72LHE, 85L or 85LHE lumen packages. Not available with GZ10 or GZ1 driver. For ordering logic consult: RRL_2013. Not available with any nLight Interface or Control options.
RRL_ Not available with any nLight Interface or Control options.
SLD Not available with any nLight Interface or Control options.

Multiple Diffuser Options

  • ADP: Curved Ribbed
  • ADSM: Curved Smooth
  • SDP: Square Ribbed
  • SDSM: Square Smooth
  • LUGR: Low UGR

Non-Configurable BLT

Stock items are available for quick deployment.

Catalog Description * UPC Lumens Wattage LPW Color Temperature Voltage Pallet Qty
2BLT4 40L ADP LP835 00190887470789 31.69 31.69 126.22 3500K/82 CRI 120-277 28
2BLT4 40L ADP LP840 00190887470765 32.76 31.69 128.23 4000K/82CRI 120-277 28
2BLT4 46L ADP LP835 00190887468656 40.63 38 130.5 3500K/82 CRI 120-277 28
2BLT4 46L ADP LP840 00190887468649 41.97 38 132.58 4000K/82CRI 120-277 28
2BLT4 40L ADP EL14L LP835 00190887470925 31.69 31.69 126.22 3500K/82 CRI 120-277 28
2BLT4 40L ADP EL14L LP840 00190887470918 32.76 31.69 128.23 4000K/82CRI 120-277 28
2BLT4 46L ADP EL14L LP835 00190887468670 40.63 38 130.5 3500K/82 CRI 120-277 28
2BLT4 46L ADP EL14L LP840 00190887468663 41.97 38 132.58 4000K/82CRI 120-277 28

*Generic 0-10V Dimming to 10%.

Mounting Data

Ceiling Type Appropriate Trim Type
Exposed grid tee (1" and 9/16") G
Concealed grid tee G
Plaster or plasterboard G*

*DGA accessory available to provide ceiling trim flange and fixture support for plaster or plasterboard ceiling. Recommended rough-in dimensions for DGA installation is 24-3/4" x 24-3/4" (Tolerance is +1/8", -0").

UL924 Sequence of Operation (nLight AIR EM)

The following applies to all nLight AIR devices with an EM option:

  • EM devices remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds.
  • Using the CLAIRITY+ mobile app, EM devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts.
  • Only non-emergency rPP20, rLSXR, rSBOR, rSDGR, and nLight AIR luminaires with version 3.4 or later firmware can provide normal power sensing for EM devices. Consult specification sheets for control devices and luminaires for more information on options that support normal power sensing.

Accessories & Replacement Parts ➕?

Accessories

  • DGA24: Drywall grid adapter for 2x4 recessed fixture
  • 2X4SMKSHP: Surface Mount Troffer Kit
  • PAF: Post Paint
  • RK8BDP 2P U: Disconnect Plug (BDP), 2 Pole, Package of 1
  • RK8BDP 3P U: Disconnect Plug (BDP), 3 Pole, Package of 1
  • RK8BDP 2P J10: Disconnect Plug (BDP), 2 Pole, Package of 10
  • RK8BDP 2P J40: Disconnect Plug (BDP), 2 Pole, Package of 40

Replacement Parts

  • 2DBLT48 ADP LENS ASSEMBLY
  • 2DBLT48 SDP LENS ASSEMBLY
  • 2DBLT48 ADSM LENS ASSEMBLY
  • 2DBLT48 SDSM LENS ASSEMBLY
  • 2DBLT48 ADPT LENS ASSEMBLY
  • 2DBLT48 SDPT LENS ASSEMBLY
  • 2DBLT48 ADSMT LENS ASSEMBLY
  • 2DBLT48 SDSMT LENS ASSEMBLY
  • 2DBLT48 ADPT SENSOR LENS ASSEMBLY
  • 2DBLT48 SDPT SENSOR LENS ASSEMBLY
  • 2DBLT48 ADSMT SENSOR LENS ASSEMBLY
  • 2DBLT48 SDSMT SENSOR LENS ASSEMBLY

Emergency Battery Pack Options ?

Field installable battery packs.

Battery Model Number Wattage Runtime (Minutes) Lumen Output* @ 120 Lumens/Watt Other
ILB CP07 2H A 7W 120 840 Storm Shelter/ 2-hour Runtime
ILB CP10 A 10W 90 1200
ILB CP10 HE AELR A 10W 90 1200 Title 20; Enabled with Self Testing, Automated Reporting (STAR)
ILBLP CP10 HE SD A 10W 90 1200 Title 20, Self Diagnostic
ILBLP CP15 HE SD A 15W 90 1800 Title 20, Self Diagnostic
ILB CP20 HE A 20W 90 2400 Title 20
ILB CP20 HE SD A 20W 90 2400 Title 20, Self Diagnostic

All listed are UL Listed products certified for field install external/remote to the fixture. *Minimum delivered lumen output to assist in product selection for increased fixture mounting height. The CP10 delivered emergency illumination outperforms legacy 1400 lumen fluorescent emergency ballast. Contact techsupport@iotaengineering.com for Emergency Battery related questions.

BSE Labeling Options

BSE10: Drivers load transfer relay installed per manufacturer's instructions. Voltage, BGTD and BSE10 called out. BSE14: One voltage fixture with driver load control relay supplied with one prewire (PWS option). Prewire wired for normal circuit, the control relay for emergency circuit left unconnected. Voltage, BGTD, BSE14 and prewire called out in the description. *For configurations with Reloc or two voltages an RFA modification is required.

Emergency Lighting with STAR ?

Emergency Lighting with Self-Testing Automated Reporting (STAR) enables self-testing and automated reporting to aid in life safety code compliance. Solutions include Mobile STAR (test data logged in unit and broadcast to CLAIRITY+ app) or Connected STAR (test data logged in STAR Gateway by IOTA® and emailed directly). Eliminate ladders, disruptions, and written records with STAR-enabled emergency lighting.

Life Safety Code Requirements (NFPA 101)

  • Testing for 30 seconds every 30 days
  • Testing for 90 minutes once a year
  • Record keeping and reporting to the authority having local jurisdiction

Performance Data ?

Unified Glare Rating (UGR)

UGR values for BLT 2x4 @ 80CRI and 3500K. UGR (70% 50% 20% reflectance using a 4H x 8H room size). UGR varies based on luminaire options and application parameters. Values depicted are considered "Luminaire-UGR and/or" Point-UGR" values. For a more precise maximum UGR value ("Application-UGR"), a full lighting design layout should be completed.

Lumen Package ADP ADPT ADSM ADSMT SDP SDPT SDSM SDSMT LUGR LUGRT
Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise
30L / 30LHE 16.716.8 16.620.7 16.820.5 16.720.5 16.920.4 16.620.5 16.920.4 16.920.4 16.817.4
40L / 40LHE 17.721.5 1720.6 16.820.7 16.920.6 16.820.7 17.120.5 17.120.6 16.917.2 17.818.3
48L / 48LHE 17.821.6 17.220.6 16.920.8 1720.7 16.820.7 16.820.7 17.721.7 17.821.5 17.718.2
60L / 60LHE 18.522.3 1821.5 17.721.7 17.821.5 17.821.6 17.921.6 17.821.6 1821.5 18.418.9
72L / 72LHE 18.322.2 18.322.3 17.821.8 17.921.6 17.921.6 17.721.6 18.121.5 1821.6 18.719.2
85L / 85LHE 19.123 19.123.1 18.422.5 18.522.3 18.522.3 18.122.1 18.422.2 18.819.1 19.119.6
100L 19.122.9 19.322.9 19.123.1 19.222.9 19.123 19.122.9 19.322.8 1922.9 19.820.3
120L 19.723.6 19.723.7 19.823.8 19.923.6 19.823.6 19.723.6 19.923.5 19.723.6 20.721.3

Performance Data (Standard Efficiency)

Model Number Lumens LPW Watts DLC Listing DLC ID
2BLT4 30L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 3188141.5622.5PremiumPWJDEMHS
2BLT4 30L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 3276145.4422.5PremiumP18J5GLD
2BLT4 30L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 3201142.1322.5PremiumP3HB2XSG
2BLT4 40L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 4197137.8130.5PremiumPDWKYXFD
2BLT4 40L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 4312141.5830.5PremiumPEYXAZWD
2BLT4 40L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 4102134.6730.5PremiumPS63CPK6
2BLT4 40L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 4214138.3630.5PremiumPK79UR9W
2BLT4 48L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 5032128.0939.3PremiumPJ9CK6C1
2BLT4 48L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 5169131.639.3PremiumP9W2R5AK
2BLT4 48L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 4917125.1739.3PremiumPPFKZU3U
2BLT4 48L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 5052128.639.3PremiumPC8HMCH9
2BLT4 60L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 6083130.5446.6PremiumPSJ6QERM
2BLT4 60L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 6250134.1246.6PremiumPVXQXPUV
2BLT4 60L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 5944127.5746.6PremiumPHT84BW4
2BLT4 60L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 6107131.0646.6PremiumPXV55BC8
2BLT4 72L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 7493126.659.2StandardPDQS3CYK
2BLT4 72L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 7322123.759.2StandardP2KKMMVN
2BLT4 72L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 7322123.6959.2StandardPYD2GO6V
2BLT4 72L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 7523127.0859.2StandardP8Z4IV4X
2BLT4 85L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 8572128.4366.7StandardPTZEW3QM
2BLT4 85L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 8699130.3366.7StandardP01DMEK9
2BLT4 85L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 8377125.566.7StandardPGM4Y7DP
2BLT4 85L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 8501127.3666.7StandardP0ODDCG2
2BLT4 120L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 11716130.6389.7StandardPXM0FS09
2BLT4 120L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 11889132.5689.7StandardPJ4GEBZM
2BLT4 120L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 11449127.6589.7StandardPJ4GEBZM
2BLT4 120L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 11619129.5489.7StandardPJ4GEBZM

DLC information is subject to change; refer to www.dlc.org for the most up-to-date information. Above listings do not cover 347V or SLD options.

HE Performance Data (High Efficiency)

Model Number Lumens LPW Watts DLC Listing DLC ID
2BLT4 30LHE ADP EZ1 (GZ1, GZ10) LP835 [All Options] 3138135.1623.2PremiumP7KEICW5
2BLT4 30LHE ADP EZ1 (GZ1, GZ10) LP840 [All Options] 3224138.8623.2PremiumPDOM06BH
2BLT4 30LHE ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 3067132.0823.2PremiumP7PZAJDZ
2BLT4 30LHE ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 3151135.723.2PremiumP2N23EBP
2BLT4 40LHE ADP EZ1 (GZ1, GZ10) LP835 [All Options] 4111142.9828.8PremiumP67P6S5Y
2BLT4 40LHE ADP EZ1 (GZ1, GZ10) LP840 [All Options] 4224146.928.8PremiumP95UQD66
2BLT4 40LHE ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 4018139.7328.8PremiumPC15DQEC
2BLT4 40LHE ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 4128143.5528.8PremiumPGRCSJ2T
2BLT4 48LHE ADP EZ1 (GZ1, GZ10) LP835 [All Options] 5424158.1634.3PremiumPXBJBGN8
2BLT4 48LHE ADP EZ1 (GZ1, GZ10) LP840 [All Options] 5573162.534.3PremiumP5PQ5RRX
2BLT4 48LHE ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 5301154.5634.3PremiumP2NK2H33
2BLT4 48LHE ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 5446158.834.3PremiumPK8C1321
2BLT4 60LHE ADP EZ1 (GZ1, GZ10) LP835 [All Options] 5970139.6442.8PremiumPQZN176R
2BLT4 60LHE ADP EZ1 (GZ1, GZ10) LP840 [All Options] 6134143.4642.8PremiumPG5CYJUC
2BLT4 60LHE ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 5834136.4642.8PremiumPZ72TAWM
2BLT4 60LHE ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 5994140.1942.8PremiumPRC4W72B
2BLT4 72LHE ADP EZ1 (GZ1, GZ10) LP835 [All Options] 7275144.1950.5StandardPUB38GEQ
2BLT4 72LHE ADP EZ1 (GZ1, GZ10) LP840 [All Options] 7475148.1450.5StandardP7GDHZTN
2BLT4 72LHE ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 7110140.9150.5StandardP5CC2VKV
2BLT4 72LHE ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 7304144.7750.5StandardP6P1BKDM
2BLT4 85LHE ADP EZ1 (GZ1, GZ10) LP835 [All Options] 8162130.7662.4StandardPRTW6BXW
2BLT4 85LHE ADP EZ1 (GZ1, GZ10) LP840 [All Options] 8283132.6962.4StandardP6H1V2D6
2BLT4 85LHE ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 7977127.7862.4StandardP1VG5TA3
2BLT4 85LHE ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 8095129.6762.4StandardPN5BKJ6E

DLC information is subject to change; refer to www.dlc.org for the most up-to-date information. Above listings do not cover 347V or SLD options.

How to Estimate Delivered Lumens in Emergency Mode

Use the formula below: Delivered Lumens = 1.25 x P x LPW, where P = Output power of the emergency driver (e.g., 10W for E10WLCP option), and LPW = Lumen per watt rating of the luminaire (available in the Performance Data section).

Constant Lumen Management ?

The embedded nLight control enables the BLT to actively track its run-time and manage its light source to maintain constant lumen output over the system life. This feature, known as lumen management, eliminates energy waste from over-lighting.

Without Lumen Management: Energy is wasted, and light levels are inconsistent over time. The graph shows power input remaining constant while light output decreases.

With Lumen Management: Energy is saved, and light levels remain consistent over time. The graph shows power input adjusting to maintain constant light output.

(Description of the graph: A visual representation comparing two lines over time. One line shows constant power input and decreasing light output (wasted energy). The other line shows adjusted power input to maintain constant light output, indicating saved energy.)

Controls Overview

SensorSwitch™ Standalone Controls

SensorSwitch™ offers standalone wired and wireless lighting controls solutions designed for room-based applications, providing reliable performance and ease of installation. Visit Sensorswitch.com.

Wired Embedded Controls

Installation steps: 1. Install luminaires with embedded controls. 2. Install and wire the wall switch to power. 3. Connect load and 0-10 dimming wires from the wall switch to the luminaires. Example: SensorSwitch WSXA D.

Wireless Embedded Controls

Installation steps: 1. Install luminaires with embedded controls. 2. Insert the pairing tool into the pinhole on the wall switch; press and hold any button for 6 seconds. 3. Once paired, each fixture will individually dim to 10% brightness. All products will be fully functional. Example: SensorSwitch WSXA JOT.

nLight® Networked Controls

nLight® is a networked lighting controls platform for indoor and outdoor applications, offering wired or wireless options. It scales from room to campus-wide applications, addressing energy cost optimization, code compliance, and occupant comfort. nLight also interfaces with DALI®, BACnet®, DMX, and other third-party devices. Visit nLIGHTcontrols.com.

Wired Embedded Controls

Installation steps: 1. Install luminaires with embedded controls. 2. Install the nLight Wired wall switch. 3. Connect luminaires using standard CAT-5e cables; controls devices automatically discover each other and work (plug and play). Example: nLight nPODMA DX.

Wireless Embedded Controls

Installation steps: 1. Install luminaires with embedded controls. 2. Install the nLight AIR battery-powered wall switch. 3. Use CLAIRITY+ mobile app to pair the fixture with the wall switch and customize sensor settings as desired. Example: nLight nPODBA 2P DX Mobile Device.

Sensor Options

Option Automatic Dimming Photocell Occupancy Sensing (PIR / PDT) nLight Wired Networking nLight AIR Networking
MSD7ADCX X PIR
MSDPDT7ADCX X PDT
NES7 PIR X
NES7ADCX X PIR X
NESPDT7 PDT X
NESPDT7ADCX X PDT X
RES7 PIR X
RESPDT7 PDT X

Sensor Descriptions

Embedded Controls by SensorSwitch:

  • The MSD7ADCX PIR occupancy sensor/automatic dimming photocell is ideal for areas without obstructions where daylight harvesting is desired (e.g., hallways, corridors, storage rooms, breakrooms).
  • The MSDPDT7ADCX PIR/Microphonics Dual Tech occupancy sensor/automatic dimming photocell is ideal for areas with obstructions and daylight harvesting needs (e.g., open offices, private offices, classrooms, restrooms, conference rooms).

Sequence of Operation (PIR/PDT Sensor)

(Description of the flowchart: When motion is detected, lights turn ON. After a time delay (e.g., 17.5 min), if no motion is detected, lights dim to 1% for 2.5 min, then turn OFF. If room is unoccupied, lights remain OFF.)

*The presetting on the automatic dimming photocell is 5fc.

Sensor Coverage Pattern

Mini 360° Lens: Recommended for walking motion detection from 8 ft (2.44 m) to 20 ft (6.10 m) mounting heights. Provides initial detection of walking motion along sensor axes at distances up to 2x mounting height (max 15 ft / 4.57 m) or 1.75x (max 20 ft / 6.10 m). Offers 12 ft (3.66 m) radial detection of small motion when mounted at 9 ft (2.74 m). Initial detection occurs earlier when walking across the field of view than directly towards the sensor.

(Description of the coverage pattern diagram: A circular pattern showing detection zones radiating from a central point, with labels indicating distances in feet and meters at a 9 ft mounting height.)

Sequence of Operation (NES7 and RES7)

(Description of the flowchart: When motion is detected, lights turn ON. After a 7.5 min time delay, if no motion is detected, lights dim to 1% for 2.5 min, then turn OFF. If the room is unoccupied, lights remain OFF.)

*The presetting on the automatic dimming photocell is 5fc (NES7) and 10fc (RES7).

nLight AIR Wireless

nLight AIR is ideal for retrofit or new construction where adding wiring is labor-intensive. It's available with or without an integral sensor. Integrated rES7 or rES7PDT smart sensors are part of each luminaire in the nLight AIR network, which can be grouped to control multiple luminaires. Granular control with digital PIR occupancy detection and daylight sensing suits any application.

  • The nES 7 is ideal for small rooms without obstructions or areas with primarily walking motion (hallways, corridors, storage rooms, breakrooms). The nES7ADCX includes an integrated photocell for daylight harvesting.
  • For areas with obstructions (restrooms, private offices, open offices, conference rooms), the nES PDT 7 dual technology sensor is recommended. It uses both PIR and Microphonics technologies. The nESPDT7ADCX includes an integrated photocell for daylight harvesting, ideal for areas with windows.

Controls Accessories

nLight® Wired Control Accessories

Order as separate catalog numbers. Visit www.acuitybrands.com/products/controls/nlight.

  • WallPod stations: On/Off, On/Off & raise/lower, Graphic touchscreen, Photocell controls, Full range dimming. (e.g., nPODTOUCH[Color])
  • Occupancy sensors: Small motion 360°, ceiling (PIR / dual tech) (e.g., nPODMA [Color]), Large motion 360°, ceiling (PIR / dual tech) (e.g., nPODMA DX [Color]).
  • Other: nWSX PDT LV DX [color] (Wallswitch), CAT5 10FT J1 (10' cable), CAT5 30FT J1 (30' cable).

BLT fixtures with integrated rIO devices complement small office spaces. Pair them with an rCMS occupancy sensor for wireless occupancy sensing and dimming capability. Consult Tech Support for additional configuration options.

nLight® AIR Control Accessories

Order as separate catalog numbers. Visit www.acuitybrands.com/products/controls/nlightair.

  • Wall switches: On/Off single pole, On/Off two pole, On/Off & raise/lower single pole, On/Off & raise/lower two pole. (e.g., rPODBA [color] G2)
  • Sensors: RCMS (nLight AIR occupancy and daylight sensor). Example: RCMS PDT 10 AR G2. Requires low voltage power from RPP20 DS 24V G2 or PS150.

PDF preview unavailable. Download the PDF instead.

blt-2x4 Adobe PDF Library 17.0 Adobe InDesign 20.5 (Macintosh)

Related Documents

Preview Lithonia Lighting 2BLT2: 2'x2' Volumetric Recessed LED Luminaire Specifications & Features
Detailed specifications, features, ordering information, and performance data for the Lithonia Lighting 2BLT2 2'x2' volumetric recessed LED luminaire, highlighting energy efficiency, control options, and design versatility for commercial applications.
Preview Lithonia Lighting 2GTL Series LED Recessed Troffer - Product Specifications and Ordering
Explore the Lithonia Lighting 2GTL Series 2'x4' LED Recessed Troffer. This document details features, specifications, ordering information, performance data, and photometrics for this energy-efficient lighting solution suitable for commercial and institutional applications.
Preview Lithonia Lighting RTL Volumetric Recessed LED Luminaires - Specifications and Ordering
Detailed specifications, features, ordering information, and performance data for the Lithonia Lighting RTL Volumetric Recessed LED Luminaire series. Includes technical details on optics, electrical components, controls, and installation.
Preview Lithonia Lighting 2BLT2: 2'x2' Volumetric Recessed LED Luminaire
Detailed specifications and features for the Lithonia Lighting 2BLT2, a 2'x2' volumetric recessed LED luminaire. Learn about its construction, optics, electrical specifications, nLight controls integration, and ordering options.
Preview Lithonia Lighting BLT4R: 1'x4' Volumetric Recessed LED Relight Troffer
Explore the Lithonia Lighting BLT4R, a versatile 1'x4' LED relight troffer designed for efficient retrofitting of existing fluorescent fixtures. Features include advanced nLight and SensorSwitch controls, various diffuser options, and high-performance LED illumination for commercial interiors.
Preview Lithonia Lighting CPX & CPXS LED Flat Panels: High-Efficiency Commercial Lighting
Discover the Lithonia Lighting CPX and CPXS Series LED Flat Panels, offering superior low-glare illumination for commercial applications. Featuring integrated nLight controls, energy efficiency, and versatile options for offices, schools, and healthcare. Learn about specifications, features, and controls.
Preview Lithonia Lighting 2BLT2R: 2'x2' LED Relight Fixture - Features, Specs, and Controls
Explore the Lithonia Lighting 2BLT2R, a 2'x2' LED relight fixture designed for efficient retrofitting of fluorescent troffers. This document details its features, specifications, advanced nLight and SensorSwitch control options, installation guidance, performance data, and compliance information.
Preview Lithonia Lighting 2BLT4R LED Relight Troffer: Features, Specifications, and Controls
The Lithonia Lighting 2BLT4R is a 2'x4' LED relight troffer designed for efficient retrofitting of existing fluorescent fixtures. It offers high lumen output, multiple diffuser options, integrated nLight and SensorSwitch controls, and optional emergency battery packs.