Single Packs

Single Pack NLU11KK.1 220-240V 50Hz RSCR

Single pack code number: 195B4648

Single Pack Contents

PositionTitleCodeAmount
1Compressor NLU11KK.1105H61321
2e-PTC starting device (220V, 38Ohm, 4.8mm)103N00551
3Run capacitor holder117-03001
4Screw for bracket M4x8mm117-03011
5Run capacitor (2.5µF 320V, 4.8mm)117-71391
6Cord relief103N10101
7Cover103N20101
8Bolt joint for one compressor | M6 | ø16mm118-19171

Technical Data

Compressor

Compressor designValue
Oil typeMineral
Oil viscosity5cST
Oil quantity265cm³ / 9fl.oz
Refr. charge - tech. limit150g / 5,3oz
Free gas volume comp.2360cm³ / 79,8fl.oz
Weight12,1kg / 26,7lbs
Motor protection1# internal
Winding resistance main19Ω (at 25°C)
Winding resistance aux24Ω (at 25°C)
Max. winding temp.105°C / 221°F
Max. discharge temp.125°C / 257°F

A black Secop N-Series compressor unit is depicted.

Refrigerant(s): R600a

Displacement: 11,15cm³ / 0,68cu.in

Compressors on pallet: 80

General Configurations with NLU11KK.1

ParameterConf. 1
MotorconfigurationRSCR
Power supply (nominal)220-240V/50Hz
Number of phases1
Voltage range198-254V
ApprovalsVDE
Starting torqueLST
Note-/-

Applications with NLU11KK.1

ParameterConf. 1
RefrigerantR600a
ApplicationLBP
System coolingstatic
Hot gas defrost-/-
Long interval pull down-/-

Electrical Data - Configurations with NLU11KK.1

ParameterConf. 1
Starting device typePTC
Run capacitor2µF
Start capacitor-/-
LRA (locked rotor amps / 4s)3,4A
RLA (rated load amps / 1s)0,6A
Cut in current6,2A

Compressor Dimensions

Housing Dimensions

A Height: 203mm / 7,99in

B Height: 197mm / 7,76in

C Length shell: 205mm / 8,07in

D Length w. cover: 254mm / 10in

E Width: 166mm / 6,54in

Connector Dimensions

ParameterSuction (X)Discharge (Y)Process (Z)
Diameter [mm] (i:inside, o:outside) [in]øi 6,11-6,29 / øi 0,24-0,25øi 5,12-5,22 / øi 0,2-0,21øi 6,11-6,29 / øi 0,24-0,25
Materialcoppercoppercopper
Horizontal angle
Vertical angle15°21°155°
Position l/h/w [mm]133/71/5791/103/81-107/94/72
Position l/h/w [in]5,2/2,8/2,23,6/4/3,2-4,2/3,7/2,8
Straight tube l. [mm]121212
Straight tube l. [in]0,50,50,5

Diagram illustrating compressor dimensions with labels A (Height), B (Height), C (Length shell), D (Length w. cover), E (Width), and showing connector positions X, Y, Z with angles and dimensions.

Compressor Fixation

ParameterBaseplate [mm] [inch]Small holes [mm] [inch]
Bl204 / 8.03Sl170 / 6.7
Bw100 / 3.94Sw70 / 2.76
S2l178 / 7
ØSØ 16 / Ø 0.63

Diagram showing compressor baseplate dimensions (BI, Bw) and mounting hole specifications (Sl, Sw, S2l, ØS).

Mounting Accessories

Accessory TypeOne Component Part No.Multi Pack Part No.
Bolt joint | M6 | ø16mm118-1917118-1918
Bolt joint | ø1/4" | ø16mm118-1946
Bolt joint | ø1/4" | ø19mm118-1949
Snap-on | ø7,3 | ø16mm118-1947118-1919

Diagrams illustrating the Bolt joint and Snap-on mounting accessories, showing their components like washers, bolts, nuts, and rubber grommets.

Ambient Conditions

Ambient Temperatures / System Cooling

Ambient temperature min.: 10°C / 50°F

Ambient temperature max.: 43°C / 110°F

T ambientLBPMBPHBP
32°C / 90°Fstaticn/an/a
38°C / 100°Fstaticn/an/a
43°C / 110°Fstaticn/an/a

Operation Pressure Range

Graph showing the operation pressure range, plotting Condensing Pressure [bara] against Evaporation Pressure [bars]. It indicates zones for continuous and transitory operation.

Electrical Accessories / Wiring Diagram

Configuration

ParameterValue
MotorconfigurationRSCR
Power supply (nominal)220-240V/50Hz 1~
RefrigerantR600a
ApplicationLBP
Voltage range198-254V
Starting torqueLST
ApprovalsVDE

Wiring Diagram

Wiring diagram for the RSCR compressor configuration, detailing connections for the main winding, start winding, PTC starter (a1), run capacitor (e), and winding protector, along with power supply inputs (N, L).

Components

ComponentDescriptionPart No.
a1e-PTC starter (220V, 38Ohm, 4.8mm)103N0055
erun capacitor (2.5µF, 4.8mm)117-7139
bplastic cover103N2010
dcord relief103N1010
bracket for run capacitor117-0300
screw M4x8mm117-0301

Alternative Components

ComponentDescriptionPart No.
a1PTC starter (220V, 25Ohm, 4.8mm)103N0021
erun capacitor (2.5µF, 4.8mm)117-7139
bplastic cover103N2011
dcord relief103N1010
gprotection screen for PTC103N0476
bracket for run capacitor117-0300
screw M4x8mm117-0301

Performance Data

Optimization + Standard Conditions

Parameters
pepcRGTTliqCooling capacity [W][Btu/h][kcal/h]COP [W/W]EER [Btu/Wh][kcal/Wh]P1 [W]I [A]m [kg/h]
[°C]-23543232199,2680171,41,976,731,70101,10,462,14
[°F]-101309090
[°C]-25553255149,3510128,51,555,291,3396,30,431,95
[°F]-1313190131
[°C]-35402040104,935890,31,595,421,3666,10,301,28
[°F]-3110468104
[°C]-23494,449162,9556140,21,665,681,4397,90,442,38
[°F]-1012040120
[°C]-23413232215,3735185,32,327,921,9992,90,422,31
[°F]-101059090
[°C]-3545324599,734185,81,495,091,2866,80,301,18
[°F]-3111390113

Note: Labels like ASHRAE LBP, cecomaf LBP, EN12900 LBP, ARI540 LBP, AHAM LBP, and 'opt' denote specific operating condition standards or optimizations.

Performance Tables

peCooling capacityCOPEER
[°C/°F][°C] [°F][W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh]P1 [W]I [A]m [kg/h]
cond. pressure-35 -3199,734185,81,495,091,2866,80,301,18
pc= 45/113-30 -22133,7456115,01,695,781,4679,00,361,59
return gas temp.-25 -13174,6596150,31,916,531,6591,30,412,08
RGT= 32/90-23 -10190,3650163,81,996,791,7195,70,432,27
liquid temp-20 -4223,6764192,52,147,321,85104,30,482,67
Tliq= 45/113-15 5281,7962242,52,388,142,05118,20,543,37
-10 14350,01195301,22,628,962,26133,40,614,19
[°C/°F][°C] [°F][W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][W][A][kg/h]
cond. pressure-35 -3181,027669,71,224,171,0566,30,301,05
pc= 55/131-30 -22112,038296,41,384,701,1881,30,371,46
return gas temp-25 -13149,3510128,51,555,291,3396,30,431,95
RGT= 32/90-23 -10163,5559140,71,615,501,39101,50,462,13
liquid temp-20 -4193,8662166,81,745,931,49111,60,512,53
Tliq= 55/131-15 5246,7843212,31,936,611,66127,50,583,23
-10 14309,01055265,92,147,311,84144,50,664,06

Service and Repair

Service/Repair – R600a, R290

Diagrams illustrating correct and incorrect brazing techniques for refrigerant lines, along with warning symbols for R600a and R290 refrigerants.

Brazing on Suction Connectors (Direct Intake)

Representative image

❗ max. 150°C/302°F ❗ at socket

Brazing solder: phosphor (LP7) or silver

Refer to Product Bulletin: Brazing on Suction Connectors (Compressors with Direct Suction Intake)

Secop GmbH, Lise-Meitner-Straße 29, 24941 Flensburg, Germany. Tel: +49 461 49410. www.secop.com

Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved.

PDF preview unavailable. Download the PDF instead.

single-pack-195B4648 GPL Ghostscript 10.05.1

Related Documents

Preview Secop KLF5.6CND Compressor Technical Data and Specifications
Comprehensive technical specifications, dimensions, performance data, configuration details, and service information for the Secop KLF5.6CND compressor, designed for 220-240V, 50Hz operation with R290 refrigerant.
Preview Secop SC10DL Compressor: Technical Data, Specifications, and Performance
Comprehensive technical datasheet for the Secop SC10DL compressor (Model 104L2525), detailing its specifications, dimensions, electrical data, performance tables, and operating limits for refrigerants like R404A, R507, and R407C. Includes single pack component list and service information for R290.
Preview Secop HTK95AA Compressor Technical Data and Specifications
Comprehensive technical data sheet for the Secop HTK95AA compressor, covering single pack details, design specifications, dimensions, electrical data, performance tables, and configuration options for both RSIR and RSCR models. Includes service and repair notes for R600a refrigerant.
Preview Secop KLF4.0CND Compressor Technical Data and Specifications
Detailed technical specifications, dimensions, performance data, and configuration details for the Secop KLF4.0CND hermetic compressor, designed for 220-240V, 50Hz operation with R290 refrigerant. It covers single pack contents, compressor design, general configurations (CSIR and RSCR), applications, electrical data, dimensional data, fixation, mounting accessories, operating conditions, performance tables, and service/repair information.
Preview Secop NLX13KK.3 Compressor: Technical Specifications, Performance Data, and Components
Comprehensive technical specifications, performance data, component list, and safety information for the Secop NLX13KK.3 High Energy-optimized Compressor (R600a, 220-240V 50Hz, RSCR). Includes application details, cooling requirements, motor and design specifications, and accessory information.
Preview Secop HTK55AA Compressor Technical Data and Specifications
Detailed technical specifications, dimensions, performance data, and configuration options for the Secop HTK55AA compressor, designed for R600a refrigerant.
Preview Secop NL11F Standard Compressor R134a Technical Specifications and Parts
Comprehensive technical datasheet for the Secop NL11F Standard Compressor (R134a, 220-240V 50Hz CSIR). Includes general specifications, cooling requirements, motor and design details, performance tables (EN 12900, ASHRAE), accessories, mounting information, and service/repair guidelines.
Preview Secop HXK13AT Compressor Technical Data and Specifications
Detailed technical data, specifications, dimensions, performance tables, and wiring diagrams for the Secop HXK13AT compressor, suitable for R600a refrigerant and 200-240V/50Hz applications.