Secop Single Pack HTK55AA 220-240V 50Hz RSIR

Single Pack Code Number: 195B4529

PositionTitleCodeAmount
1Compressor HTK55AA161227001
2Clip106339004
3Steel pin106341004
4Washer106343004
5Screw for cable clamp106360001
6Screw for cable clamp106362001
7Cover106364011
8Earth screw106412011
9Rubber grommet 16mm113226004
10Cable clamp113410001
11Terminal board 4.8mm151657001

Technical Data

Compressor Design

Oil typeMineral
Oil viscosity5cST
Oil quantity162cm³ / 5.5fl.oz
Refr. charge - tech. limit150g / 5.3oz
Free gas volume comp.1500cm³ / 50.7fl.oz
Weight7.8kg / 17.2lbs
Motor protectionexternal
Winding resistance main32.7Ω (at 25°C)
Winding resistance aux29.2Ω (at 25°C)
Max. winding temp.130°C / 266°F
Max. discharge temp.130°C / 266°F
Refrigerant(s)R600a
Displacement5.6cm³ / 0.34cu.in
Compressors on pallet100

Illustration of the Secop K-Series compressor, showing its main body, electrical connections, and a label indicating 'K-Series'.

General Configurations with HTK55AA

Conf. 1Conf. 2
MotorconfigurationRSIRRSCR
Power supply (nominal)220-240V/50Hz220-240V/50Hz
Number of phases11
Voltage range187-264V187-264V
ApprovalsVDEVDE
Starting torqueLSTLST

Note: Various options of connectors are possible - please contact SECOP-Sales.

Applications with HTK55AA

Conf. 1Conf. 2
RefrigerantR600aR600a
ApplicationLBPLBP
System coolingstaticstatic
Hot gas defrost-/--/-
Long interval pull down-/--/-

Electrical Data - Configurations with HTK55AA

Conf. 1Conf. 2
Starting device typePTCPTC
Run capacitor-/-2.5μF
Start capacitor-/--/-
LRA (locked rotor amps / 4s/ U(N))-/-A-/-A
RLA (rated load amps / 1s/ U(N))-/-A-/-A
Cut in current (U(N))

Compressor Dimensions and Fixation

Compressor Dimensions

Housing

A Height166mm / 6.54in
B Height159mm / 6.26in
C Length shell194mm / 7.64in
D Length w. cover238mm / 9.37in
E Width151mm / 5.94in

Connectors

Suction (X)Discharge (Y)Process (Z)
Diameter [mm]øi 6.1-6.2øi 5.1-5.2øi 5.92-6.08
(i:inside, o:outside) [in]øi 0.24-0.24øi 0.2-0.2øi 0.23-0.24
Materialcoppercoppercopper
Horizontal angle±2°45°13°
Vertical angle±2°30°40°145°
Position l/h/w [mm]120/72/62112/106/62-140/136/70
[in]4.7/2.8/2.44.4/4.2/2.4-5.5/5.4/2.8
Straight tube l. [mm]141475
[in]0.50.53

Diagram illustrating compressor dimensions labeled A (Height), B (Height), C (Length shell), D (Length w. cover), E (Width), Z, and other reference points. Another diagram shows connector ports X (Suction), Y (Discharge), Z (Process) with their dimensions and angles. A third diagram depicts compressor fixation points (Baseplate, Small holes) with dimensions. Finally, diagrams show the 'Bolt joint' and 'Snap-on' mounting methods.

Compressor Fixation

[mm][inch]
Baseplate BI2048.03
Bw1003.94
Small holes SI1706.7
Sw702.76
S21787
ØSØ 16Ø 0.63
S2l7.8

Mounting Accessories

DescriptionOrder Code
'4ZN' with rubber grommet772N
'4ZN' with rubber grommet and sleeve for M6768N
Bolt joint kit4ZN + 118-1917 (18)
'4ZN' with Snap on kit776N

Application Notes

Provision for PE Grounding is located at the PE Stamp on the compressor.

Housing with dip-tray fixture (omega bracket).

Note: Various options of connectors are possible - please contact SECOP-Sales.

Configuration Details

Conf. 1 (RSIR)

MotorconfigurationRSIR
Power supply (nominal)220-240V/50Hz 1~
RefrigerantR600a
ApplicationLBP
Voltage range187-264V
Starting torqueLST
ApprovalsVDE

Ambient/Machine Room Temperatures Minimum/Maximum:

Electrical accessories / wiring diagram for RSIR configuration, showing connections for Thermostat, Terminal board (incl. PTC, external protector), Cable clamp, Cover, and a 5th contact (optional).

Operation Pressure Range

Graph showing Condensing Pressure (saturation temperature) vs. Evaporation Pressure (saturation temperature) for continuous and transitory operation.

Components

ItemCode
Terminal board (PTC, 4.8mm)15165700
Cover terminal board10636401
Cable clamp11341000
Screw - uni695410636000
Screw - uni695410636200
Screw uni en iso 475710641201

Conf. 2 (RSCR)

MotorconfigurationRSCR
Power supply (nominal)220-240V/50Hz 1~
RefrigerantR600a
ApplicationLBP
Voltage range187-264V
Starting torqueLST
ApprovalsVDE

Ambient/Machine Room Temperatures Minimum/Maximum:

Electrical accessories / wiring diagram for RSCR configuration, showing connections for Run capacitor, Thermostat, Terminal board (incl. PTC, external protector), Cable clamp, Cover, and a 5th contact (optional).

Operation Pressure Range

Graph showing Condensing Pressure (saturation temperature) vs. Evaporation Pressure (saturation temperature) for continuous and transitory operation.

Components

ItemCode
Terminal board (PTC, 4.8mm)15165700
Run capacitor (2.5μF, 4.8mm)10692802
Cover terminal board10636401
Cable clamp11341000
Screw - uni695410636000
Screw - uni695410636200

Performance Data

Optimization + Standard Conditions

Conditions: R600a, 220V/50Hz, RSIR, static, VDE

pe [°C][°F]Cooling capacityCOPEERP1 [W]Current consumptionApplication
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][A][kg/h]
-23-1093.031880.01.555.291.3360.00.401.00ASHRAE LBP
-25-1368.723559.11.204.091.0357.30.390.90cecomaf LBP
-35-3141.014035.31.023.500.8840.00.330.50EN12900 LBP
-23-1076.726266.01.314.481.1358.50.391.12ARI540 LBP
-23-10103.035288.71.826.231.5756.50.381.11AHAM LBP
-35-3138.813333.40.973.300.8340.20.320.46opt

Performance Tables

Conditions: R600a, 220V/50Hz, RSIR, static, VDE

peCooling capacityCOPEERP1 [W]Current consumptionRef. mass flow [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][A]
[°C / °F]
-35 / -3138.813333.40.973.300.8340.20.320.46
-30 / -2258.920150.71.234.191.0648.00.350.70
-25 / -1381.928070.51.485.061.2755.30.380.97
-23 / -1090.430977.81.575.351.3557.70.391.08
-20 / -4107.936992.91.735.921.4962.30.411.29
-15 / 5137.2468118.11.996.781.7169.10.441.64
-5 / 23205.9703177.22.508.532.1582.40.502.47
-35 / -3131.710827.20.802.730.6939.70.310.41
-30 / -2248.516641.81.003.420.8648.50.350.63
-25 / -1368.723559.11.204.091.0357.30.390.90
-23 / -1076.326165.71.274.321.0960.30.401.00
-20 / -492.331579.41.404.771.2066.10.421.21
-15 / 5119.5408102.81.595.441.3775.00.461.56
-5 / 23185.1632159.31.986.761.7093.50.542.44

Service and Repair Information

Service/Repair – R600a

Illustration of a Secop K-Series compressor with electrical connections. A separate diagram shows the wiring for the 5th contact, terminal N, and terminal S. The 'Service/Repair – R600a' section includes diagrams with icons indicating prohibited actions (e.g., connecting/disconnecting lines with refrigerant under pressure ⚠️ R600a), and a warning symbol ❗.

PDF preview unavailable. Download the PDF instead.

single-pack-195B4529 GPL Ghostscript 10.05.1

Related Documents

PreviewSecop NLE9KTK Compressor Technical Data and Specifications
Detailed technical specifications, performance data, configurations, and dimensions for the Secop NLE9KTK compressor, designed for R600a refrigerant. Includes information on electrical accessories, operating conditions, and service notes.
PreviewSecop HTK95AA Compressor Technical Data and Specifications
Comprehensive technical data sheet for the Secop HTK95AA compressor, covering single pack details, design specifications, dimensions, electrical data, performance tables, and configuration options for both RSIR and RSCR models. Includes service and repair notes for R600a refrigerant.
PreviewSecop HTK70AA Compressor: Technical Data and Specifications
Detailed technical data sheet for the Secop HTK70AA compressor, a K-Series unit operating on 220-240V/50Hz. Includes specifications, performance tables, dimensions, and application details for R600a refrigerant.
PreviewSecop NLU11KK.1 Compressor Technical Data and Specifications
Detailed technical specifications, performance data, dimensions, and service information for the Secop NLU11KK.1 compressor, designed for 220-240V, 50Hz, RSCR applications using R600a refrigerant.
PreviewSecop HXK95AT Compressor Technical Data and Specifications
Comprehensive technical data, specifications, and configuration details for the Secop HXK95AT compressor, including performance tables, electrical data, and dimensions.
PreviewSecop NLE15KTK.2 R600a Compressor - Technical Specifications and Data
Detailed technical specifications, performance data, dimensions, and accessories for the Secop NLE15KTK.2 R600a energy-optimized tropical compressor (220-240V 50Hz).
PreviewSecop HKK70AA Compressor Technical Data and Specifications
Detailed technical data, specifications, performance tables, dimensions, and application notes for the Secop HKK70AA compressor, designed for 220-240V, 50Hz operation with R600a refrigerant.
PreviewSecop HXK70AA Compressor Technical Data Sheet - R600a, 220-240V/50Hz
Detailed technical specifications, performance data, dimensions, and electrical information for the Secop HXK70AA hermetic compressor. This document covers R600a refrigerant compatibility, 220-240V/50Hz operation, and various configurations. Includes service and repair guidance.