Secop KLF4.0CND Compressor

Technical Data and Specifications for 220-240V 50Hz Models

Product Overview

This document provides comprehensive technical data for the Secop KLF4.0CND hermetic compressor, designed for 220-240V, 50Hz electrical supply and utilizing R290 refrigerant. It covers single pack contents, detailed specifications, dimensional data, electrical configurations (CSIR and RSCR), performance tables, and service/repair information.

Single Pack Contents

The single pack for model 195B4623 includes the following items:

PositionTitleCodeAmount
1Compressor KLF4.0CND106H24011
2KL accessories103N10601
3Starting capacitor (80µF 220V, 6.3mm)117U50011
4Starting relay (QLZ-4.6A, overload protector T1189/L6)117U70731
5Bolt joint for one compressor | M6 | ø16mm118-19171

Technical Data - Compressor KLF4.0CND

Compressor Design & General Specifications

Model DesignationKLF4.0CND
Voltage / Frequency220-240V/50Hz 1~
Sales Code106H2401
Oil typePolyolester
Oil viscosity10.4cSt
Oil quantity170cm³ / 5.7fl.oz
Refrigerant charge - tech. limit200g / 7.1oz
Free gas volume comp.1630cm³ / 55.1fl.oz
Weight8.95kg / 19.7lbs
Motor protectionexternal
Winding resistance main13.1Ω (at 25°C)
Winding resistance aux25.3Ω (at 25°C)
Max. winding temp.125°C / 257°F
Max. discharge temp.130°C / 266°F
Refrigerant(s)R290
Displacement4cm³ / 0.24cu.in
Compressors on pallet100

A black Secop KL-Series hermetic compressor, model KLF4.0CND, is shown.

General Configurations

FeatureConf. 1Conf. 2
MotorconfigurationCSIRRSCR
Power supply (nominal)220-240V/50Hz220-240V/50Hz
Number of phases11
Voltage range198-254V198-254V
ApprovalsVDE, CCCVDE, CCC
Starting torqueHSTLST
Note-/ -

Applications

FeatureConf. 1Conf. 2
RefrigerantR290R290
ApplicationLBP+MBPLBP+MBP
System coolingfan 3m/sfan 3m/s
Hot gas defrostOKOK
Long interval pull downOKOK

Electrical Data

FeatureConf. 1Conf. 2
Starting device typerelayPTC
Run capacitor-/-5µF
Start capacitor80µF-/-
LRA (locked rotor amps / 4s/ U(N))10.2A10.2A
RLA (rated load amps / 1s/ U(N))1.4A1.4A
Cut in current (U(N))10.2A12.65A

Compressor Dimensions and Fixation

Dimensions

Diagrams illustrate the compressor's external dimensions and connector sizes.

DimensionValue (mm)Value (in)
A Height1827.17
B Height1756.89
C Length shell1987.8
D Length w. cover2389.37
E Width1606.3
ConnectorSuction (X)Discharge (Y)Process (Z)
mminmminmmin
Diameter (i:inside, o:outside)øi 8.11-8.29øi 0.32-0.33øi 6.11-6.29øi 0.24-0.25øi 6.11-6.29øi 0.24-0.25
Materialcoppercoppercopper
Horizontal angle35°13°
Vertical angle+2°30°40°
Position l/h/w119/73/594.7/2.9/2.3117/107/664.6/4.2/2.6-88/101/71-3.5/4/2.8
Straight tube l.140.5140.5140.5

Compressor Fixation

Diagrams show baseplate dimensions, hole sizes for mounting, and examples of bolt joint and snap-on accessory attachments.

PartBaseplateLarge holesSmall holes
mminchmminchmminch
Bl2048.031656.51706.7
Bw1325.2
ØEØ 9.7Ø 0.38
ØL--101.64--
ØS--Ø 19Ø 0.75Ø 16Ø 0.63

Mounting Accessories

AccessoryOne Comp.Multi Pack
Bolt joint | M6 | ø16mm118-1917118-1918
Bolt joint | ø1/4" | ø16mm118-1946-
Bolt joint | ø1/4" | ø19mm118-1949-
Snap-on | ø7,3 | ø16mm118-1947118-1919

Provision for PE Grounding is located at the PE Stamp on the compressor.

Operating Conditions and Performance

Ambient and Machine Room Temperatures

ParameterMinMax
Ambient temperature range10°C / 50°F43°C / 110°F
Machine room temperature range10°C / 50°F48°C / 119°F
Compressor coolingfan 3m/s

Operation Pressure Range

Graphs illustrate the relationship between condensing and evaporation pressures for continuous and transitory operation modes.

Configuration 1 (CSIR):

Operating PointEvaporation Pressure (pe)Condensing Pressure (pc)
°C°F°C°F
ASHRAE LBP-23-1054130
cecomaf LBP-25-1355131
EN12900 LBP-35-3140104
ASHRAE MBP-72054130
cecomaf MBP-101455131
EN12900 MBP-101445113

Configuration 2 (RSCR):

Operating PointEvaporation Pressure (pe)Condensing Pressure (pc)
°C°F°C°F
ASHRAE LBP-23-1054130
cecomaf LBP-25-1355131
EN12900 LBP-35-3140104
ASHRAE MBP-72054130
cecomaf MBP-101455131
EN12900 MBP-101445113

Performance Tables

Detailed performance data (Cooling Capacity, COP, EER, Power Consumption, Current Consumption, Ref. mass flow) for various operating conditions are provided for both configurations. Key parameters include evaporating pressure (pe), condensing pressure (pc), return gas temperature (RGT), and liquid temperature (Tliq).

Configuration 1 (CSIR) Performance Summary:

ConditionCooling CapacityCOP / EERP1 [W]I [A]m [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh]
pc=45/113°F
pe=-35°C/-31°F95.432682.11.033.520.8992.40.921.07
pe=-25°C/-13°F163.7559140.91.485.041.27111.00.961.85
pe=-15°C/5°F (RGT=32/90°F)254.8870219.31.956.671.68130.41.012.90
pe=-5°C/23°F (RGT=32/90°F)376.51286324.02.548.672.18148.41.064.33
pe=0°C/32°F (Tliq=45/113°F)451.31541388.42.899.882.49156.01.085.24
pe=7.2°C/45°F (Tliq=45/113°F)578.11974497.53.5111.993.02164.71.116.79
pc=55/131°F
pe=-35°C/-31°F74.425464.00.742.520.64100.60.940.92
pe=-25°C/-13°F135.8464116.91.133.850.97120.60.991.69
pe=-15°C/5°F (RGT=32/90°F)215.8737185.71.515.151.30143.21.052.71
pe=-5°C/23°F (RGT=32/90°F)322.21100277.31.946.631.67166.01.114.10
pe=0°C/32°F (Tliq=55/131°F)387.81324333.82.197.491.89176.81.154.98
pe=7.2°C/45°F (Tliq=55/131°F)499.51706429.92.628.952.25190.71.206.51

Configuration 2 (RSCR) Performance Summary:

ConditionCooling CapacityCOP / EERP1 [W]I [A]m [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh]
pc=45/113°F
pe=-35°C/-31°F95.532682.21.033.510.8893.00.581.07
pe=-25°C/-13°F164.1560141.21.495.091.28110.10.641.85
pe=-15°C/5°F (RGT=32/90°F)255.4872219.81.996.801.71128.20.712.91
pe=-5°C/23°F (RGT=32/90°F)377.41289324.82.618.902.24144.90.774.35
pe=0°C/32°F (Tliq=45/113°F)452.51545389.42.9810.172.56152.00.805.25
pe=7.2°C/45°F (Tliq=45/113°F)579.61979498.83.6212.373.12160.00.836.81
pc=55/131°F
pe=-35°C/-31°F74.525464.10.742.530.64100.50.610.92
pe=-25°C/-13°F136.1465117.11.143.900.98119.00.671.69
pe=-15°C/5°F (RGT=32/90°F)216.3739186.11.545.271.33140.10.752.72
pe=-5°C/23°F (RGT=32/90°F)323.11103278.02.006.841.72161.30.844.12
pe=0°C/32°F (Tliq=55/131°F)388.91328334.72.277.751.95171.30.885.00
pe=7.2°C/45°F (Tliq=55/131°F)501.01711431.22.729.292.34184.10.936.53

Electrical Accessories and Wiring Diagrams

Diagrams show the electrical components and wiring for both CSIR (Conf. 1) and RSCR (Conf. 2) configurations, including relays, capacitors, and terminal boxes.

Configuration 1 (CSIR) Components

ComponentDescriptionCode
a5Current relay (T1189/L6-S3)117U7073
cStart capacitor (80µF, 6.3mm)117U5001
b, dCover + clamp + screws (5VA-compl.)103N0600

Configuration 2 (RSCR) Components

ComponentDescriptionCode
a4DAS3 (PTC, 6.3mm, T1189/L6 - S3)103N0254
eRun capacitor (5µF, 6.3mm)117-7191
b, dCover + clamp + screws (5VA-compl.)103N0600

Alternative Components

ConfigurationComponentDescriptionCode
Conf. 1b, d100x cover + clamp + screws (5VA)103N2060
Conf. 1b, dCover + clamp + screws (5VA) in bag103N1060
Conf. 2a4ZAS3 (PTC, 4.8mm, T1189/L6 - S3)103N0255
Conf. 2eRun capacitor (5µF, 4.8mm)117-7190
Conf. 2b, d100x cover + clamp + screws (5VA)103N2060
Conf. 2b, dCover + clamp + screws (5VA) in bag103N1060

Noise Emission

ParameterValue
Operation pressurespe: -10°C / 14°F, pc: 45°C / 113°F
Motor speed appr.2900rpm
Lw(A)46dB(A)

Service and Repair Information

⚠️ This section provides guidance for service and repair, specifically for R290 refrigerant.

A warning symbol indicates that R290 is a flammable refrigerant.

Diagrams illustrate correct and incorrect procedures. A crossed-out pipe symbol indicates an incorrect connection or handling method.

A correct connection is shown with a checkmark symbol ✔️.

Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. All trademarks are the property of their respective companies. Secop and the Secop logotype are trademarks of Secop GmbH.

PDF preview unavailable. Download the PDF instead.

single-pack-195B4623 GPL Ghostscript 10.05.1

Related Documents

PreviewSecop KLF5.6CND Compressor Technical Data Sheet & Overview
Comprehensive technical specifications, performance data, dimensions, and configuration details for the Secop KLF5.6CND 220-240V 50Hz RSCR compressor. Includes single pack contents and service information.
PreviewSECOP KLF4.8CND Compressor Technical Data Sheet
Detailed technical specifications for the SECOP KLF4.8CND compressor, including electrical data, performance tables, operating ranges, and configuration details for CSIR and RSCR motor types. Suitable for R290 refrigerant.
PreviewSECOP KLF4.8CND Compressor Technical Data Sheet
Detailed technical specifications, performance data, dimensions, and configuration options for the SECOP KLF4.8CND R290 compressor, designed for 220-240V/50Hz operation.
PreviewSecop NLE10CNT Compressor Technical Data Sheet
Comprehensive technical data sheet for the Secop NLE10CNT compressor, detailing specifications, configurations (CSIR, RSIR, RSCR), electrical data, performance tables, dimensions, and operating parameters for 220-230V 50Hz and 208-230V 60Hz applications. Includes service and repair information.
PreviewSECOP KLF7.7CND Compressor Technical Data Sheet
Detailed technical specifications, performance data, and configuration information for the SECOP KLF7.7CND compressor, designed for R290 refrigerant and 220-240V/50Hz power supply. Includes dimensions, electrical data, and operational parameters.
PreviewSecop KLF7.7MFT Compressor: Technical Specifications, Configurations, and Performance Data
Comprehensive technical datasheet for the Secop KLF7.7MFT compressor, detailing specifications, four configurations (CSIR/RSCR, 200-240V/50Hz, 208-230V/60Hz), performance tables, dimensions, electrical data, and application notes.
PreviewSecop NL9CN Compressor: Technical Specifications, Data, and Accessories
Detailed technical specifications, performance data, component list, and accessory information for the Secop NL9CN LBP/MBP Compressor (R290, 220-240V 50Hz CSIR).
PreviewSECOP KLF4.8CND Compressor Technical Data Sheet
Detailed technical specifications, dimensions, electrical data, operating ranges, and performance tables for the SECOP KLF4.8CND compressor, designed for R290 refrigerant and operating at 220-240V/50Hz.