Secop KLF5.6CND Compressor Technical Data

Model: KLF5.6CND

Designation: 220-240V/50Hz 1~

Sales Code: 106H2600

Single Pack Overview

Product Name: Single Pack KLF5.6CND 220-240V 50Hz CSIR

Single Pack Code Number: 195B4595

Single Pack Components

PositionTitleCodeAmount
1Compressor KLF5.6CND106H26001
2KL accessories103N10601
3Starting capacitor (80µF 220V, 6.3mm)117U50011
4Starting relay (QLZ-4.4A, overload protector T0089/L6)117U70701
5Bolt joint for one compressor | M6 | ø16mm118-19171

Compressor Design Details

ParameterValue
Oil typePolyolester
Oil viscosity10,4 cSt
Oil quantity170cm³ / 5,7fl.oz
Refr. charge - tech. limit200g / 7,1oz
Free gas volume comp.1605cm³ / 54,3fl.oz
Weight9,4kg / 20,7lbs
Motor protectionexternal
Winding resistance main10,7Ω (at 25°C)
Winding resistance aux17Ω (at 25°C)
Max. winding temp.125°C / 257°F
Max. discharge temp.130°C / 266°F

Compressor Image Description

A visual representation of the Secop KL-Series compressor unit is provided, showing its main body and connections.

General Configurations

ConfigurationConf. 1Conf. 2
Motor configurationCSIRRSCR
Power supply (nominal)220-240V/50Hz220-240V/50Hz
Number of phases1~1~
Voltage range198-254V198-254V
ApprovalsVDE, CCCVDE, CCC
Starting torqueHSTLST
Note- / -- / -

Applications

ConfigurationConf. 1Conf. 2
RefrigerantR290R290
ApplicationLBP+MBPLBP+MBP
System coolingfan 3m/sfan 3m/s
Hot gas defrostOKOK
Long interval pull downOKOK

Electrical Data

ConfigurationConf. 1Conf. 2
Starting device typerelayPTC
Run capacitor-/-5µF
Start capacitor80µF-/-
LRA (locked rotor amps / 4s/ U(N))11,4A11,4A
RLA (rated load amps / 1s/ U(N))1,6A1,6A
Cut in current (U(N))10,7A14,7A

Compressor Dimensions

DimensionValue (mm)Value (in)
A Height1827,17
B Height1756,89
C Length shell1987,8
D Length w. cover2389,37
E Width1606,3

Connector Dimensions and Angles

ParameterConnector Type
Suction (X)Discharge (Y)Process (Z)
Diameter [mm] (i:inside, o:outside)øi 8,11-8,29øi 6,11-6,29øi 6,11-6,29
Diameter [in] (i:inside, o:outside)øi 0,32-0,33øi 0,24-0,25øi 0,24-0,25
Materialcoppercoppercopper
Horizontal angle [°]±2°35°13°
Vertical angle [°]±2°30°40°145°
Position l/h/w [mm]119/73/59117/107/66-88/101/71
Position l/h/w [in]4,7/2,9/2,34,6/4,2/2,6-3,5/4/2,8
Straight tube l. [mm]141414
Straight tube l. [in]0,50,50,5

Compressor Fixation

Diagrams show mounting hole patterns and dimensions for compressor fixation. Key dimensions include Baseplate (Bl, Bw), Large holes (ØL), and Small holes (ØS), with values provided in mm and inches.

Baseplate Dimensions:

Large holes:

Small holes:

Mounting Accessories

Accessory TypePart Number (one comp.)Part Number (multi pack)
Bolt joint | M6 | Ø16mm118-1917118-1918
Bolt joint | Ø1/4" | Ø16mm118-1946
Bolt joint | Ø1/4" | Ø19mm118-1949118-1919
Snap-on | Ø7,3 | Ø16mm118-1947

Application Notes

Provision for PE Grounding is located at the PE Stamp on the compressor.

Configuration 1: CSIR

Electrical Accessories / Wiring Diagram (Conf. 1)

A diagram illustrates the electrical accessories and wiring for Configuration 1 (CSIR). It shows components including a current relay (a5, part code 117U7070), a start capacitor (c, part code 117U5001), and a cover with clamp and screws (b, d, part code 103N0600). An alternative wiring configuration is also indicated.

Ambient and Machine Room Temperatures (Conf. 1)

ParameterValue
Ambient temperature range:10 - 43°C / 50 - 110°F
Machine room temperature range:10 - 48°C / 50 - 119°F
Compressor cooling:fan 3m/s

Operation Pressure Range (Conf. 1)

Two graphs illustrate the operation pressure ranges. The top graph shows condensing pressure (sat. temp.) in °C and °F against evaporation pressure (sat. temp.) in bar. Lines indicate continuous and transitory operation. The bottom graph shows condensing pressure in bar against evaporation pressure in bar.

Components (Conf. 1)

Component IDDescriptionCode
a5current relay (T0089/L6-S2)117U7070
cstart capacitor (80µF, 6.3mm)117U5001
b, dcover + clamp + screws (5VA-compl.)103N0600

Alternative Components (Conf. 1)

Component IDDescriptionCode
b, d100x cover + clamp + screws(5VA)103N2060
b, dcover + clamp + screws(5VA) in bag103N1060

Configuration 2: RSCR

Electrical Accessories / Wiring Diagram (Conf. 2)

A diagram illustrates the electrical accessories and wiring for Configuration 2 (RSCR). It shows components including a DAS2 PTC (a4, part code 103N0251), a run capacitor (e, part code 117-7191), and a cover with clamp and screws (b, d, part code 103N0600). An alternative wiring configuration is also indicated.

Ambient and Machine Room Temperatures (Conf. 2)

ParameterValue
Ambient temperature range:10 - 43°C / 50 - 110°F
Machine room temperature range:10 - 48°C / 50 - 119°F
Compressor cooling:fan 3m/s

Operation Pressure Range (Conf. 2)

Two graphs illustrate the operation pressure ranges, similar to Conf. 1, showing condensing pressure vs. evaporation pressure for continuous and transitory operation.

Components (Conf. 2)

Component IDDescriptionCode
a4DAS2 (PTC,6.3mm, T0089/L6 - S2)103N0251
erun capacitor (5µF, 6.3mm)117-7191
b, dcover + clamp + screws(5VA-compl.)103N0600

Alternative Components (Conf. 2)

Component IDDescriptionCode
a4ZAS2 (PTC,4.8mm, T0089/L6 - S2)103N0253
erun capacitor (5µF, 4.8mm)117-7190
b, d100x cover + clamp + screws(5VA)103N2060
b, dcover + clamp + screws(5VA) in bag103N1060

Performance Data

Optimization + Standard Conditions (Conf. 1)

pepcRGTTliqCooling capacityCOPEERPower consumption P1 [W]Current consumption I [A]Ref. mass flow m [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh]
[°C] -23543232273,6934235,51,555,281,33177,11,222,77ASHRAE LBP
[°F] -101309090
[°C] -25553255203,7696175,31,194,071,03170,91,202,54cecomaf LBP
[°F] -1313190131
[°C] -35402040149,1509128,31,214,121,04123,41,071,70EN12900 LBP
[°F] -3110468104
[°C] -7543546494,71690425,82,077,081,78238,81,435,64ASHRAE MBP
[°F] 2013095115
[°C] -10553255392,21339337,51,725,871,48228,21,394,96cecomaf MBP
[°F] 1413190131
[°C] -10452045435,11486374,42,097,141,80208,01,325,34EN12900 MBP
[°F] 1411368113

Performance Tables (Conf. 1)

peCooling capacityCOPEERP1 [W]I [A]m [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh]
[°C/°F]
cond. pressure pc= 45/113
-40 / -40112,638596,90,973,310,84116,11,061,26
-35 / -31148,4507127,71,143,880,98130,61,091,66
-25 / -13241,0823207,41,495,081,28162,11,172,72
return gas temp. RGT= 32/90
-15 / 5370,81266319,11,926,541,65193,51,274,22
-5 / 23548,31872471,92,488,472,14221,01,366,31
liquid temp Tliq= 45/113
0 / 32658,22248566,52,849,692,44232,01,407,63
7,2 / 45844,82885727,13,4711,852,99243,51,459,93
[°C/°F]
cond. pressure pc= 55/131
-40 / -4076,026065,40,652,240,56116,11,060,94
-35 / -31114,038998,10,862,920,74133,31,101,41
-25 / -13203,7696175,31,194,071,03170,91,202,54
return gas temp RGT= 32/90
-15 / 5320,41094275,71,535,221,32209,61,334,03
-5 / 23474,81621408,61,936,601,66245,71,466,05
liquid temp Tliq= 55/131
0 / 32569,41945490,02,187,431,87261,51,527,31
7,2 / 45729,52491627,82,608,882,24280,51,599,50

Optimization + Standard Conditions (Conf. 2)

pepcRGTTliqCooling capacityCOPEERPower consumption P1 [W]Current consumption I [A]Ref. mass flow m [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh]
[°C] -23543232276,8945238,21,625,521,39171,30,922,80ASHRAE LBP
[°F] -101309090
[°C] -25553255206,0704177,31,254,261,07165,30,902,57cecomaf LBP
[°F] -1313190131
[°C] -35402040150,7515129,71,264,291,08120,00,731,72EN12900 LBP
[°F] -3110468104
[°C] -7543546500,81710431,02,177,401,86231,21,175,71ASHRAE MBP
[°F] 2013095115
[°C] -10553255397,01356341,71,806,141,55221,01,135,02cecomaf MBP
[°F] 1413190131
[°C] -10452045440,31504378,92,187,461,88201,51,055,41EN12900 MBP
[°F] 1411368113

Performance Tables (Conf. 2)

peCooling capacityCOPEERP1 [W]I [A]m [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh]
[°C/°F]
cond. pressure pc= 45/113
-40 / -40113,938998,01,013,440,87113,10,711,27
-35 / -31150,0512129,11,184,041,02126,80,751,68
-25 / -13243,8833209,81,555,311,34156,90,862,75
return gas temp. RGT= 32/90
-15 / 5375,21281322,92,006,841,72187,40,994,27
-5 / 23554,91895477,62,598,852,23214,21,106,39
liquid temp Tliq= 45/113
0 / 32666,22275573,42,9610,112,55225,01,157,73
7,2 / 45855,22921736,03,6212,373,12236,21,2010,05
[°C/°F]
cond. pressure pc= 55/131
-40 / -4076,926366,20,682,330,59112,90,710,95
-35 / -31115,339499,20,893,050,77129,20,761,43
-25 / -13206,0704177,31,254,261,07165,30,902,57
return gas temp RGT= 32/90
-15 / 5324,21107279,01,605,461,38202,91,054,08
-5 / 23480,61642413,72,026,901,74237,91,206,12
liquid temp Tliq= 55/131
0 / 32576,51969496,22,287,771,96253,31,277,41
7,2 / 45738,82523635,82,729,292,34271,51,359,62

Service and Repair Information

Service/Repair - R290

This section provides guidance for service and repair, specifically for systems using R290 refrigerant.

Safety Warnings

A prominent warning symbol ⚠️ indicates that R290 is a flammable refrigerant.

Diagrams illustrate correct and incorrect procedures for handling refrigerant lines. An "X" symbol ❌ indicates an incorrect method, while a checkmark ✔️ indicates the correct method.

PDF preview unavailable. Download the PDF instead.

single-pack-195B4595 GPL Ghostscript 10.05.1

Related Documents

PreviewSecop KLF5.6CND Compressor Technical Data Sheet & Overview
Comprehensive technical specifications, performance data, dimensions, and configuration details for the Secop KLF5.6CND 220-240V 50Hz RSCR compressor. Includes single pack contents and service information.
PreviewSECOP KLF5.6CND Compressor Technical Data Sheet
Detailed technical specifications, performance data, dimensions, and electrical information for the SECOP KLF5.6CND hermetic compressor, designed for R290 refrigerant and 220-240V/50Hz operation.
PreviewSecop SC10DL Compressor: Technical Data, Specifications, and Performance
Comprehensive technical datasheet for the Secop SC10DL compressor (Model 104L2525), detailing its specifications, dimensions, electrical data, performance tables, and operating limits for refrigerants like R404A, R507, and R407C. Includes single pack component list and service information for R290.
PreviewSecop KLF4.0CND Compressor Technical Data and Specifications
Detailed technical specifications, dimensions, performance data, and configuration details for the Secop KLF4.0CND hermetic compressor, designed for 220-240V, 50Hz operation with R290 refrigerant. It covers single pack contents, compressor design, general configurations (CSIR and RSCR), applications, electrical data, dimensional data, fixation, mounting accessories, operating conditions, performance tables, and service/repair information.
PreviewSecop NLU11KK.1 Compressor Technical Data and Specifications
Detailed technical specifications, performance data, dimensions, and service information for the Secop NLU11KK.1 compressor, designed for 220-240V, 50Hz, RSCR applications using R600a refrigerant.
PreviewSecop NLE12.6CNL Compressor Technical Data and Specifications
Detailed technical specifications, configurations, performance data, and dimensions for the Secop NLE12.6CNL compressor, including single pack information and electrical diagrams.