ℹ️ Document Conversion Notice:
This document has been converted from PDF and formatted to fit this screen. Diagrams and images may be available only in the original here.
Secop NLX13KK.3 Compressor
Secop NLX13KK.3 High Energy-optimized Compressor
220-240V 50Hz RSCR
Single Pack Code Number: 195B4276
Single Pack Components
Position
Title
Code
Amount
1
Compressor NLX13KK.3
105H6306
1
2
e-PTC starting device (220V, 25Ω, 4.8mm)
103N0050
1
3
Run capacitor (4µF 320V, 4.8mm)
117-7119
1
4
Cord relief
103N1010
1
5
Cover
103N2010
1
6
Bolt joint for one compressor | M6 | Ø16mm
118-1917
1
Compressor Overview
General Information
Code number
105H6306
Approvals
EN 60335-2-34 with Annex AA
Compressors on pallet
80
Application
Application
Frequency
LBP
Hz
50
60
Evaporating temperature
°C
-35 to -10
Voltage range
V
198 - 254
Max. condensing temperature continuous (short)
°C
60 (70)
Max. winding temperature continuous (short)
°C
120 (125)
Cooling Requirements
Frequency
LBP
MBP
HBP
LBP
MBP
HBP
Hz
Application
32°C
S
S
38°C
S
S
43°C
S
S
Cooling Requirement Symbols: S = Static cooling normally sufficient; Ø = Oil cooling; F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature); F2 = Fan cooling 3.0 m/s necessary; SG = Suction gas cooling normally sufficient; ? = not applicable in this area.
Technical Specifications
Motor
Motor type
RSCR
LRA (rated after 4 sec. UL984), HST | LST
A
5.3
Cut in Current, HST | LST
A
8.9
Resistance, main | start winding (25°C)
Ω
18.0 | 18.8
Design
cm³
Displacement
13.25
Oil quantity (type)
270 (mineral)
Maximum refrigerant charge
g
150
Free gas volume in compressor
cm³
2360
Weight without electrical equipment
kg
10.8
Dimensions
Detailed dimensions of the compressor unit. Key measurements include overall height (A: 203mm), width (B: 197mm), and depth. Connection ports are labeled C (Suction, 6.2mm I.D. at 15°), D (Process, 6.2mm I.D. at 25°), E (Discharge, 5.0mm I.D. at 21°), and F (Oil cooler, not specified). A bolt joint of Ø16mm is indicated.
⚠️ Warning: Flammable Refrigerant (R600a) and R290.
Diagrams illustrate typical electrical connections for RSCR compressors, showing main winding, start winding, capacitor, and protector. Refer to specific wiring diagrams for detailed installation.
Illustrations show component assembly and general compressor layout. Ensure correct component placement and secure connections.
Brazing on Suction Connectors (Direct Intake). Maximum temperature at socket: 150°C / 302°F. Recommended brazing solder: phosphor (LP7) or silver.
Refer to Product Bulletin: Brazing on Suction Connectors (Compressors with Direct Suction Intake).
Diagram showing correct and incorrect methods for handling refrigerant lines, with a checkmark for the correct procedure.
Secop PLE35K Energy-Optimized Compressor R600a - Technical Specifications Detailed technical specifications and performance data for the Secop PLE35K energy-optimized compressor, R600a refrigerant, 220-240V, 50Hz, RSCR type. Includes performance tables, dimensions, and accessory information.
Secop NL9CN Compressor Technical Specifications and Data Comprehensive technical data, performance charts, application details, and service information for the Secop NL9CN LBP/MBP R290 compressor (220-240V, 50Hz, CSIR). Includes specifications, cooling requirements, motor details, dimensions, accessories, and safety guidelines.
Secop NLU11KK.1 Compressor Technical Data and Specifications Detailed technical specifications, performance data, dimensions, and service information for the Secop NLU11KK.1 compressor, designed for 220-240V, 50Hz, RSCR applications using R600a refrigerant.
Secop PL35G Universal Compressor R134a Datasheet and Specifications Detailed technical specifications, performance data, accessories, and dimensions for the Secop PL35G Universal Compressor (R134a, 220-240V 50/60Hz CSIR). Includes EN 12900 and ASHRAE LBP performance tables.