Secop NL11F Standard Compressor
Technical Specifications and Parts
Product Overview
Product Name: NL11F Standard Compressor
Refrigerant: R134a
Voltage: 220-240V
Frequency: 50Hz
Type: CSIR
Single Pack Code: 195B4113
Single Pack Components
Position | Title | Code | Amount |
---|---|---|---|
1 | Compressor NL11F | 105G6900 | 1 |
2 | Starting relay | 117U6002 | 1 |
3 | Starting capacitor (80µF 220V, 6.3mm) | 117U5015 | 1 |
4 | Cord relief | 103N1010 | 1 |
5 | Cover | 103N2010 | 1 |
6 | Bolt joint for one compressor | M6 | ø16mm | 118-1917 | 1 |
General Specifications
General
Code number | 105G6900 |
Approvals | EN 60335-2-34 with Annex AA |
Compressors on pallet | 80 |
Application
Application | LBP (Low Back Pressure) |
Frequency | 50 Hz / 60 Hz |
Evaporating temperature | -35 to -10 °C |
Voltage range | 198-254 V |
Max. condensing temperature continuous (short) | 60 °C (70 °C) |
Max. winding temperature continuous (short) | 125 °C (135 °C) |
Cooling Requirements
Cooling Requirements
Frequency | Application | Temperatures | Symbol Key |
---|---|---|---|
50 Hz, 60 Hz | LBP, MBP, HBP | 32°C, 38°C, 43°C | S = Static cooling normally sufficient O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufficient ❌ = not applicable in this area |
Motor and Design
Motor
Motor type | RSIR/CSIR |
LRA (rated after 4 sec. UL984), HST | LST | 10.4 A | 9.2 A |
Cut in Current, HST | LST | 10.4 A | 13.6 A |
Resistance, main | start winding (25°C) | 8.2 Ω | 14.7 Ω |
Design
Displacement | 11.15 cm³ |
Oil quantity (type) | 300 cm³ |
Maximum refrigerant charge | 400 g |
Free gas volume in compressor | 2360 cm³ |
Weight without electrical equipment | 10.7 kg |
Dimensions and Connectors
Dimensions
Dimension | Value |
Height (A) | 203 mm |
(B) | 197 mm |
(B1) | [Value not specified] |
(B2) | [Value not specified] |
Connectors
Type | Location/I.D. | Angle | Material/Comment |
---|---|---|---|
Suction connector | C, 8.2 mm | 15° | Copper | Rubber plug |
Process connector | D, 6.2 mm | 25° | Copper | Rubber plug |
Discharge connector | E, 6.2 mm | 35° | Copper | Rubber plug |
Oil cooler connector | F | [Value not specified] | [Value not specified] | [Value not specified] |
Connector tolerance | ±0.09 mm |
Performance Data
Performance Data (EN 12900 Household, CECOMAF) - 220V, 50Hz, fan cooling F1
Evap. temp in °C | Capacity in W | Power cons. in W | Current cons. in A | COP in W/W |
---|---|---|---|---|
-45 | 102 | 137 | 1.41 | 0.75 |
-40 | 146 | 175 | 1.46 | 0.83 |
-35 | 200 | 212 | 1.54 | 0.94 |
-30 | 222 | 225 | 1.58 | 0.99 |
-25 | 268 | 250 | 1.66 | 1.07 |
-23.3 | 351 | 289 | 1.82 | 1.22 |
-20 | 453 | 331 | 2.01 | 1.37 |
Performance Data (ASHRAE LBP) - 220V, 50Hz, fan cooling F1
Evap. temp in °C | Capacity in W | Power cons. in W | Current cons. in A | COP in W/W |
---|---|---|---|---|
-45 | 126 | 138 | 1.41 | 0.92 |
-40 | 180 | 175 | 1.46 | 1.03 |
-35 | 247 | 212 | 1.54 | 1.17 |
-30 | 274 | 224 | 1.57 | 1.22 |
-25 | 332 | 249 | 1.66 | 1.33 |
-23.3 | 435 | 287 | 1.81 | 1.51 |
-20 | 560 | 329 | 2.00 | 1.70 |
Accessories and Mounting
Accessories for NL11F
Figure | Code number | Test conditions | EN 12900/ CECOMAF | ASHRAE | |
---|---|---|---|---|---|
PTC starting device | a1 | 103N0011 | Condensing temperature | 54.4°C | 55°C |
103N0018 | Ambient temperature | 32°C | 32°C | ||
Starting relay | a2 | 117U6002 | Suction gas temperature | 32°C | 32°C |
Start capacitor 80 µF | c | 117U5015 | Liquid temperature | no subcooling | 32°C |
Cover | b | 103N2010 | |||
Cord relief | d | 103N1010 | |||
Protection screen for PTC | g | 103N0476 |
Mounting accessories
Item | Diameter | Code number |
---|---|---|
Bolt joint for one comp. | Ø: 16 mm | 118-1917 |
Bolt joint in quantities | Ø: 16 mm | 118-1918 |
Snap-on in quantities | Ø: 16 mm | 118-1919 |
Diagrams and Wiring
The document includes several diagrams illustrating compressor components, wiring configurations, and service procedures:
- A schematic representation of the NL11F compressor showing its overall dimensions and connector locations (Suction, Process, Discharge, Oil Cooler).
- Wiring diagrams for RSIR and CSIR compressor types, detailing the connections for main winding, start winding, and winding protector.
- General diagrams of compressor types and their electrical connections, including references to refrigerants R600a and R290.
Service and Repair Information
Refrigerant Handling
Warnings are provided for handling specific refrigerants:
- ? R600a
- ? R290
Brazing Connectors
Instructions and warnings for brazing on suction connectors (direct intake) are detailed:
- ❌ Incorrect brazing method illustrated.
- ❗ Warning symbol indicating caution.
- ✔️ Correct brazing method illustrated.
Maximum temperature at socket: 150°C / 302°F
Brazing solder: phosphor (LP7) or silver.
Refer to Product Bulletin: Brazing on Suction Connectors (Compressors with Direct Suction Intake).
Company Information
Secop GmbH
Lise-Meitner-Straße 29
24941 Flensburg, Germany
Tel: +49 461 49410
Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved.