Secop SC10DL Compressor

Model: SC10DL | Sales Code: 104L2525 | Power: 220-240V 50Hz 1~

Single Pack Information

Single pack code number: 195B4041

PositionTitleCodeAmount
1Compressor SC10DL104L25251
2Starting relay117U60051
3Starting capacitor (80µF 220V, 6.3mm)117U50171
4Cord relief103N10041
5Cover103N20091
6Bolt joint for one compressor | M6 | ø16mm118-19171

Technical Data - Compressor Design

Model Designation: SC10DL

Compressor Design:

Refrigerant(s): R404A, R507, R407C

Displacement: 10.29cm³ / 0.63cu.in

Compressors on pallet: 80

Description of Compressor Image: A visual representation of the Secop SC10DL compressor, featuring the Secop S-Series branding.

General Configurations (SC10DL)

Configuration: Conf. 1

Applications (SC10DL)

Configuration: Conf. 1

Electrical Data (SC10DL)

Configuration: Conf. 1

Compressor Dimensions

Housing Dimensions:

Connectors:

Suction (X)Discharge (Y)Process (Z)
Diameter [mm] (i:inside, o:outside) [in]øi 8.11-8.29 (øi 0.32-0.33)øi 6.11-6.29 (øi 0.24-0.25)øi 6.11-6.29 (øi 0.24-0.25)
Materialcoppercoppercopper
Horizontal angle37°37°143°
Vertical angle+2°30°150°
Position l/h/w [mm] [in]107/193/55 (4.2/7.6/2.2)115/110/63 (4.5/4.3/2.5)-107/193/55 (-4.2/7.6/2.2)
Straight tube l. [mm] [in]12 (0.5)12 (0.5)12 (0.5)

Description of Dimension Diagram: A diagram illustrating the compressor's housing dimensions labeled A through E, and connector positions X, Y, Z with their respective angles and dimensions. It also shows the vertical and horizontal angles for connectors.

Compressor Fixation

Description of Compressor Fixation Diagram: This diagram details the baseplate dimensions (Bl, Bw, ØE) and hole sizes (Large holes: Ll, Lw, ØL; Small holes: Sl, Sw, ØS, Ql, Qw) for compressor mounting. It includes measurements in both millimeters and inches.

Baseplate Dimensions:

[mm][inch]
Bl2048.03
Bw1505.9
ØEØ 9.7Ø 0.38

Large Holes:

[mm][inch]
Ll1656.5
Lw101.64
ØLØ 19Ø 0.75

Small Holes:

[mm][inch]
Sl1706.7
Sw702.76
ØSØ 16Ø 0.63
Ql1275
Qw1275

Mounting Accessories:

Accessory TypePart Number (one comp.)Part Number (multi pack)
Bolt joint | M6 | Ø16mm118-1917118-1918
Bolt joint | Ø1/4" | Ø16mm118-1946118-1949
Bolt joint | Ø1/4" | Ø19mm118-1947118-1919
Snap-on | Ø7.3 | Ø16mm

Description of Bolt Joint Diagram: Illustrates a bolt joint assembly including a bolt, washer, nut, compressor base, cabinet base, and rubber grommet.

Description of Snap-on Diagram: Shows a snap-on fastener assembly with a compressor base, clip, steel pin, cabinet base, and rubber grommet.

Application notes: Provision for PE Grounding is located at the PE Stamp on the compressor.

Operation and Limits

Configuration: Conf. 1

Ambient/Machine Room Temperatures

Operation Pressure Range Graph

Description of Operation Pressure Range Graph: This graph plots condensing pressure (saturation temperature) against evaporation pressure (saturation temperature). The Y-axis represents condensing pressure in bar (from 0 to 80) and temperature (°C/°F from -50°C/-58°F to 102°F/22°C). The X-axis represents evaporation pressure in bar (from 0 to 22) and temperature (°C/°F from -30°C/-38°F to 102°F/42°C). Two lines indicate 'continuous operation' and 'transitory operation'.

Electrical Accessories / Wiring Diagram

Description of Electrical Accessories/Wiring Diagram: A schematic showing the electrical connections for the CSIR motor configuration. It labels components such as a relay (a2), start capacitor (c), cord relief (d), and plastic cover (b), along with terminals (10, 11, 12, 13, 14) and windings (main, start, winding protector).

Performance Data

Conditions: R404A, 220V/50Hz, CSIR, fan 3m/s, CCC, EAC, VDE

Optimization + Standard Conditions

pe [°C] [°F]pc [°C] [°F]RGT [°C] [°F]Tliq [°C] [°F]Cooling capacityCOPEERP1 [W]Current consumptionRef. mass flow [kg/h]Application
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][A]
7.2 / 4554 / 13035 / 9546 / 1151478.250481272.22.157.351.85686.73.8042.03ASHRAE HBP
5 / 4155 / 13132 / 9055 / 1311156.03948994.81.715.851.47674.93.7438.50cecomaf HBP
5 / 4150 / 12220 / 6850 / 1221208.041261039.61.926.561.65628.63.5741.20EN12900 HBP
-7 / 2054 / 13035 / 9546 / 115838.22862721.31.515.161.30554.93.2723.06ASHRAE MBP
-10 / 1455 / 13132 / 9055 / 131613.62096528.11.194.051.02517.83.1219.64cecomaf MBP
-10 / 1445 / 11320 / 6845 / 113730.52495628.71.535.211.31478.52.9722.00EN12900 MBP

Performance Tables

pe [°C] [°F]pc [°C] [°F]Cooling capacityCOPEERP1 [W]Current consumptionm [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][A]
-20 / -445 / 113471.31610405.61.264.311.09373.42.5512.79
-15 / 5610.82086525.71.424.861.23428.92.7816.69
-10 / 14775.22648667.21.625.531.39478.52.9721.35
-5 / 23967.83305832.91.856.331.60522.03.1526.91
0 / 321191.840701025.62.137.281.83559.23.3033.50
5 / 411450.449531248.22.468.402.12589.93.4241.32
15 / 592084.971201794.33.3011.282.84631.13.6161.48
-20 / -4349.81195301.00.923.150.79378.82.5911.01
-15 / 5474.11619408.01.053.590.90451.62.8715.04
-10 / 14613.62096528.11.194.051.02517.83.1219.64
-5 / 23771.62635664.01.344.571.15577.23.3524.97
0 / 32951.23249818.71.515.161.30629.63.5631.19
5 / 411156.03948994.81.715.851.47674.93.7438.50
15 / 591653.556471423.02.227.601.91743.44.0457.34

SC Compressors - Service/Repair Information

This section provides service and repair information, specifically mentioning R290 refrigerant.

Description of R290 Warning Symbol: A triangular warning symbol with a flame icon inside, indicating the presence of flammable refrigerant R290.

Description of Repair Icons: One icon shows a crossed-out connection, indicating an incorrect procedure. Another icon shows a correct connection with a checkmark, indicating the approved method.

For detailed service and repair procedures, refer to specific Secop documentation.

PDF preview unavailable. Download the PDF instead.

single-pack-195B4041 GPL Ghostscript 10.05.1

Related Documents

PreviewSecop SC10DL Compressor Technical Data, Specifications, and Service Information
Comprehensive technical data, specifications, dimensions, performance tables, wiring diagrams, and service information for the Secop SC10DL compressor, designed for 220-240V/50Hz operation. Includes single pack component details and operational limits.
PreviewSecop SC15/15CL Twin-Compressor Technical Data and Specifications
Comprehensive technical data, specifications, dimensions, electrical diagrams, and performance tables for the Secop SC15/15CL Twin-Compressor (220-240V 50Hz). Includes single pack components, compressor design details, electrical configurations, and performance metrics.
PreviewSecop KLF5.6CND Compressor Technical Data and Specifications
Comprehensive technical specifications, dimensions, performance data, configuration details, and service information for the Secop KLF5.6CND compressor, designed for 220-240V, 50Hz operation with R290 refrigerant.
PreviewSecop SC15DL Compressor: Technical Data, Specifications, and Performance
Comprehensive technical data sheet for the Secop SC15DL compressor, detailing specifications, dimensions, electrical data, operating limits, and performance tables for R404A and R407C refrigerants. Includes configuration details and service notes.
PreviewSecop NL11F Standard Compressor R134a Technical Specifications and Parts
Comprehensive technical datasheet for the Secop NL11F Standard Compressor (R134a, 220-240V 50Hz CSIR). Includes general specifications, cooling requirements, motor and design details, performance tables (EN 12900, ASHRAE), accessories, mounting information, and service/repair guidelines.
PreviewSecop NL9CLX Compressor Technical Data and Specifications
Detailed technical specifications, performance data, dimensions, and electrical information for the Secop NL9CLX compressor, designed for 220-240V, 50Hz operation.
PreviewSECOP KLF7.7CND Compressor Technical Data Sheet
Detailed technical specifications, performance data, and configuration information for the SECOP KLF7.7CND compressor, designed for R290 refrigerant and 220-240V/50Hz power supply. Includes dimensions, electrical data, and operational parameters.
PreviewSecop NL7CN Compressor: Technical Specifications, Datasheet, and Performance Data
Detailed technical specifications, performance data, accessories, and service information for the Secop NL7CN LBP/MBP R290 compressor (220-240V 50Hz). Includes EN 12900 and ASHRAE LBP ratings.