Description of Compressor Image: A visual representation of the Secop SC10DL compressor, featuring the Secop S-Series branding.
General Configurations (SC10DL)
Configuration: Conf. 1
Motorconfiguration: CSIR
Power supply (nominal): 220-240V/50Hz
Number of phases: 1
Voltage range: 198-254V
Approvals: CCC, EAC, VDE
Starting torque: HST
Note: -/-
Applications (SC10DL)
Configuration: Conf. 1
Refrigerant: R404A
Application: HBP (High Back Pressure)
System cooling: fan 3m/s
Hot gas defrost: OK
Long interval pull down: OK
Electrical Data (SC10DL)
Configuration: Conf. 1
Starting device type: relay
Run capacitor: -/-
Start capacitor: 80µF
LRA (locked rotor amps / 4s): 16.2A
RLA (rated load amps / 1s): 3.1A
Cut in current: 16.2A
Compressor Dimensions
Housing Dimensions:
A Height: 219mm / 8.62in
B Height: 213mm / 8.39in
C Length shell: 218mm / 8.58in
D Length w. cover: 255mm / 10.04in
E Width: 151mm / 5.94in
Connectors:
Suction (X)
Discharge (Y)
Process (Z)
Diameter [mm] (i:inside, o:outside) [in]
øi 8.11-8.29 (øi 0.32-0.33)
øi 6.11-6.29 (øi 0.24-0.25)
øi 6.11-6.29 (øi 0.24-0.25)
Material
copper
copper
copper
Horizontal angle
37°
37°
143°
Vertical angle
+2°
30°
150°
Position l/h/w [mm] [in]
107/193/55 (4.2/7.6/2.2)
115/110/63 (4.5/4.3/2.5)
-107/193/55 (-4.2/7.6/2.2)
Straight tube l. [mm] [in]
12 (0.5)
12 (0.5)
12 (0.5)
Description of Dimension Diagram: A diagram illustrating the compressor's housing dimensions labeled A through E, and connector positions X, Y, Z with their respective angles and dimensions. It also shows the vertical and horizontal angles for connectors.
Compressor Fixation
Description of Compressor Fixation Diagram: This diagram details the baseplate dimensions (Bl, Bw, ØE) and hole sizes (Large holes: Ll, Lw, ØL; Small holes: Sl, Sw, ØS, Ql, Qw) for compressor mounting. It includes measurements in both millimeters and inches.
Baseplate Dimensions:
[mm]
[inch]
Bl
204
8.03
Bw
150
5.9
ØE
Ø 9.7
Ø 0.38
Large Holes:
[mm]
[inch]
Ll
165
6.5
Lw
101.6
4
ØL
Ø 19
Ø 0.75
Small Holes:
[mm]
[inch]
Sl
170
6.7
Sw
70
2.76
ØS
Ø 16
Ø 0.63
Ql
127
5
Qw
127
5
Mounting Accessories:
Accessory Type
Part Number (one comp.)
Part Number (multi pack)
Bolt joint | M6 | Ø16mm
118-1917
118-1918
Bolt joint | Ø1/4" | Ø16mm
118-1946
118-1949
Bolt joint | Ø1/4" | Ø19mm
118-1947
118-1919
Snap-on | Ø7.3 | Ø16mm
Description of Bolt Joint Diagram: Illustrates a bolt joint assembly including a bolt, washer, nut, compressor base, cabinet base, and rubber grommet.
Description of Snap-on Diagram: Shows a snap-on fastener assembly with a compressor base, clip, steel pin, cabinet base, and rubber grommet.
Application notes: Provision for PE Grounding is located at the PE Stamp on the compressor.
Description of Operation Pressure Range Graph: This graph plots condensing pressure (saturation temperature) against evaporation pressure (saturation temperature). The Y-axis represents condensing pressure in bar (from 0 to 80) and temperature (°C/°F from -50°C/-58°F to 102°F/22°C). The X-axis represents evaporation pressure in bar (from 0 to 22) and temperature (°C/°F from -30°C/-38°F to 102°F/42°C). Two lines indicate 'continuous operation' and 'transitory operation'.
Electrical Accessories / Wiring Diagram
Description of Electrical Accessories/Wiring Diagram: A schematic showing the electrical connections for the CSIR motor configuration. It labels components such as a relay (a2), start capacitor (c), cord relief (d), and plastic cover (b), along with terminals (10, 11, 12, 13, 14) and windings (main, start, winding protector).
Performance Data
Conditions: R404A, 220V/50Hz, CSIR, fan 3m/s, CCC, EAC, VDE
Optimization + Standard Conditions
pe [°C] [°F]
pc [°C] [°F]
RGT [°C] [°F]
Tliq [°C] [°F]
Cooling capacity
COP
EER
P1 [W]
Current consumption
Ref. mass flow [kg/h]
Application
[W]
[Btu/h]
[kcal/h]
[W/W]
[Btu/Wh]
[kcal/Wh]
[A]
7.2 / 45
54 / 130
35 / 95
46 / 115
1478.2
5048
1272.2
2.15
7.35
1.85
686.7
3.80
42.03
ASHRAE HBP
5 / 41
55 / 131
32 / 90
55 / 131
1156.0
3948
994.8
1.71
5.85
1.47
674.9
3.74
38.50
cecomaf HBP
5 / 41
50 / 122
20 / 68
50 / 122
1208.0
4126
1039.6
1.92
6.56
1.65
628.6
3.57
41.20
EN12900 HBP
-7 / 20
54 / 130
35 / 95
46 / 115
838.2
2862
721.3
1.51
5.16
1.30
554.9
3.27
23.06
ASHRAE MBP
-10 / 14
55 / 131
32 / 90
55 / 131
613.6
2096
528.1
1.19
4.05
1.02
517.8
3.12
19.64
cecomaf MBP
-10 / 14
45 / 113
20 / 68
45 / 113
730.5
2495
628.7
1.53
5.21
1.31
478.5
2.97
22.00
EN12900 MBP
Performance Tables
pe [°C] [°F]
pc [°C] [°F]
Cooling capacity
COP
EER
P1 [W]
Current consumption
m [kg/h]
[W]
[Btu/h]
[kcal/h]
[W/W]
[Btu/Wh]
[kcal/Wh]
[A]
-20 / -4
45 / 113
471.3
1610
405.6
1.26
4.31
1.09
373.4
2.55
12.79
-15 / 5
610.8
2086
525.7
1.42
4.86
1.23
428.9
2.78
16.69
-10 / 14
775.2
2648
667.2
1.62
5.53
1.39
478.5
2.97
21.35
-5 / 23
967.8
3305
832.9
1.85
6.33
1.60
522.0
3.15
26.91
0 / 32
1191.8
4070
1025.6
2.13
7.28
1.83
559.2
3.30
33.50
5 / 41
1450.4
4953
1248.2
2.46
8.40
2.12
589.9
3.42
41.32
15 / 59
2084.9
7120
1794.3
3.30
11.28
2.84
631.1
3.61
61.48
-20 / -4
349.8
1195
301.0
0.92
3.15
0.79
378.8
2.59
11.01
-15 / 5
474.1
1619
408.0
1.05
3.59
0.90
451.6
2.87
15.04
-10 / 14
613.6
2096
528.1
1.19
4.05
1.02
517.8
3.12
19.64
-5 / 23
771.6
2635
664.0
1.34
4.57
1.15
577.2
3.35
24.97
0 / 32
951.2
3249
818.7
1.51
5.16
1.30
629.6
3.56
31.19
5 / 41
1156.0
3948
994.8
1.71
5.85
1.47
674.9
3.74
38.50
15 / 59
1653.5
5647
1423.0
2.22
7.60
1.91
743.4
4.04
57.34
SC Compressors - Service/Repair Information
This section provides service and repair information, specifically mentioning R290 refrigerant.
Description of R290 Warning Symbol: A triangular warning symbol with a flame icon inside, indicating the presence of flammable refrigerant R290.
Description of Repair Icons: One icon shows a crossed-out connection, indicating an incorrect procedure. Another icon shows a correct connection with a checkmark, indicating the approved method.
For detailed service and repair procedures, refer to specific Secop documentation.
Secop SC10DL Compressor Technical Data, Specifications, and Service Information Comprehensive technical data, specifications, dimensions, performance tables, wiring diagrams, and service information for the Secop SC10DL compressor, designed for 220-240V/50Hz operation. Includes single pack component details and operational limits.
Secop SC15/15CL Twin-Compressor Technical Data and Specifications Comprehensive technical data, specifications, dimensions, electrical diagrams, and performance tables for the Secop SC15/15CL Twin-Compressor (220-240V 50Hz). Includes single pack components, compressor design details, electrical configurations, and performance metrics.
Secop KLF5.6CND Compressor Technical Data and Specifications Comprehensive technical specifications, dimensions, performance data, configuration details, and service information for the Secop KLF5.6CND compressor, designed for 220-240V, 50Hz operation with R290 refrigerant.
Secop SC15DL Compressor: Technical Data, Specifications, and Performance Comprehensive technical data sheet for the Secop SC15DL compressor, detailing specifications, dimensions, electrical data, operating limits, and performance tables for R404A and R407C refrigerants. Includes configuration details and service notes.
Secop NL11F Standard Compressor R134a Technical Specifications and Parts Comprehensive technical datasheet for the Secop NL11F Standard Compressor (R134a, 220-240V 50Hz CSIR). Includes general specifications, cooling requirements, motor and design details, performance tables (EN 12900, ASHRAE), accessories, mounting information, and service/repair guidelines.
SECOP KLF7.7CND Compressor Technical Data Sheet Detailed technical specifications, performance data, and configuration information for the SECOP KLF7.7CND compressor, designed for R290 refrigerant and 220-240V/50Hz power supply. Includes dimensions, electrical data, and operational parameters.