XBA-JMD6 Bill Acceptor Configuration Guide
Supported Currencies
The XBA-JMD6 bill acceptor supports the following currencies: JMD 50, 100, 500, 1000, 2000, 5000 (6 denominations).
Option Switch Settings (General)
The following table details the function of each DIP switch (SW1-SW8) for general settings:
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Reject JMD 50 | ON | |||||||
Accept JMD 50 | OFF | |||||||
Reject JMD 100 & 500 | ON | |||||||
Accept JMD 100 & 500 | OFF | |||||||
Reject JMD 1000 | ON | |||||||
Accept JMD 1000 | OFF | |||||||
Reject JMD 2000 | ON | |||||||
Accept JMD 2000 | OFF | |||||||
Reject JMD 5000 | ON | |||||||
Accept JMD 5000 | OFF | |||||||
Disable Bill Reject 4 Times BA Stop By 30 Sec | ON | |||||||
Enable Bill Reject 4 Times BA Stop By 30 Sec | OFF | |||||||
Stack Banknote when Power-up | ON | |||||||
Reject Banknote when Power-up | OFF | |||||||
Enable function | ON | |||||||
No Enable function | OFF |
Option Switch Settings (Protocol Specific)
The following table details switch settings for different communication protocols: Pulse, MDB, and ICT modes.
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5/SW6 | SW7/SW8 | ||
---|---|---|---|---|---|---|---|---|
Pulse Mode | Other Mode | ICT104V Mode | ||||||
Inhibit Active HIGH | ON | |||||||
Inhibit Active LOW | OFF | |||||||
Harness Disable | ON | |||||||
Harness Enable | OFF | |||||||
50ms LO/50ms HI | OFF | OFF | ||||||
60ms LO/300ms HI | OFF | ON | ||||||
Credit-Pulse Normal LOW | ON | OFF | ||||||
30ms LO/ 50ms HI | ON | ON | ||||||
150ms LO/150ms HI | OFF | ON | ||||||
Pulse Mode | OFF | OFF | ||||||
MDB Mode | ||||||||
ICT104V Mode | ||||||||
Scaling Factor (SF) = 100 Decimal Point Position (DPP) = 2 | ON | OFF | ||||||
Scaling Factor (SF) = 1 Decimal Point Position (DPP) = 0 | ON | ON | ||||||
Pulse Mode Settings Note: 2. When DIP1 OFF: 1 pulse/ JMD 50 When DIP1 ON: 1 pulse/ JMD 100 |
MDB Mode | ICT104V Mode | ICT002U Mode | ICT104U Mode | ICT104V Mode | |||
1 pulse / JMD 50 & 100 | OFF OFF | ICT002U Mode | OFF | |||||
2 pulses / JMD 50 & 100 | OFF ON | ICT104U Mode | ON OFF | |||||
4 pulses / JMD 50 & 100 | ON OFF | ICT104V Mode | ON ON | |||||
20 pulses / JMD 50 & 100 | ON ON |
★ Manufacture setting
After setting dip switch of the credit pulses, you should reset the bill acceptor again.
Note: 1. Calibration card is needed.
DIP Switch Location and Currency Assignment
Description of Diagram 1: This diagram illustrates the physical location of the DIP switch on the side of the XBA unit. It points to the DIP switch assembly, labeled (2), and also indicates LED indicators.
This dip switch is located at the side of XBA.
Currency Assign Data
Bill value | Interface | ICT002U | ICT104U | ICT104V | DIP1 OFF (JMD 50) | DIP1 ON (JMD 100) |
MDB |
---|---|---|---|---|---|---|---|
BV1 | JMD 50 | JMD 50 | JMD 50 | JMD 50 | JMD 50 | JMD 100 | JMD 50 |
BV2 | JMD 100 | JMD 100 | JMD 100 | JMD 100 | JMD 50 | JMD 500 | JMD 100 |
BV3 | JMD 500 | JMD 500 | JMD 500 | JMD 500 | JMD 100 | JMD 1000 | JMD 500 |
BV4 | JMD 1000 | JMD 1000 | JMD 1000 | JMD 1000 | JMD 500 | JMD 5000 | JMD 1000 |
BV5 | JMD 5000 | JMD 5000 | JMD 5000 | JMD 5000 | JMD 1000 | JMD 2000 | JMD 5000 |
BV6 | JMD 2000 | JMD 2000 | JMD 2000 | JMD 2000 | JMD 5000 | JMD 2000 |
DIP Switch Access on CPU Board
Description of Diagram 2: This diagram illustrates the procedure for accessing the DIP switch located on the CPU board. It shows the unit being opened, the CPU board being removed, and a close-up view of the DIP switch labeled (1).
This dip switch is located on the CPU board, remove the CPU board cover first.