XBA-HRK9(HRK5+EUR4) Option Switch Settings
Supported bills: HRK 10, 20, 50, 100, 200 (5 bills); EUR 5, 10, 20, 50 (4 bills).
XBA-HRK9(HRK5+EUR4) Option Switch Settings
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Reject HRK 10 & 20 & 50 | ON | |||||||
Accept HRK 10 & 20 & 50 | OFF | |||||||
Reject HRK 100 & 200 | ON | |||||||
Accept HRK 100 & 200 | OFF | |||||||
Reject EUR 5 & 10 | ON | |||||||
Accept EUR 5 & 10 | OFF | |||||||
Reject EUR 20 | ON | |||||||
Accept EUR 20 | OFF | |||||||
Reject EUR 50 | ON | |||||||
Accept EUR 50 | OFF | |||||||
Disable Bill Reject 4 Times BA Stop By 30 Sec | ON | |||||||
Enable Bill Reject 4 Times BA Stop By 30 Sec | OFF | |||||||
Stack Banknote when Power-up | ON | |||||||
Reject Banknote when Power-up | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF |
This dip switch is located at the side of XBA.
[Diagram: Side view of XBA unit showing DIP switch location (2). Close-up of DIP switch.]
Appendix: Currency Assign Data
Interface | Bill value | ICT104U (Pulse) | ICT104U (MDB) | ICT104V (Pulse) | ICT104V (MDB) |
---|---|---|---|---|---|
BV1 | HRK 10 | HRK 10 | HRK 10 | HRK 10 | HRK 10 |
BV2 | HRK 20 | HRK 20 | HRK 20 | HRK 20 | HRK 20 |
BV3 | HRK 50 | HRK 50 | HRK 50 | HRK 50 | HRK 50 |
BV4 | HRK 100 | HRK 100 | HRK 100 | HRK 100 | HRK 100 |
BV5 | HRK 200 | HRK 200 | HRK 200 | HRK 200 | HRK 200 |
BV6 | EUR 5 | EUR 5 | EUR 5 | EUR 5 | EUR 5 |
BV7 | EUR 10 | EUR 10 | EUR 10 | EUR 10 | EUR 10 |
BV8 | EUR 20 | EUR 20 | EUR 20 | EUR 20 | EUR 20 |
BV9 | EUR 50 | EUR 50 | EUR 50 | EUR 50 | EUR 50 |
XBA-HRK9(HRK5+EUR4) (Pulse/MDB/ICT104U/ICT104V) Option Switch Settings
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Inhibit Active HIGH | ON | |||||||
Inhibit Active LOW | OFF | |||||||
Exchange rate 1 EUR = 7 HRK (Note.4) | ON | |||||||
Exchange rate 1 EUR = 5 HRK (Note.4) | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Pulse Mode (MDB Mode) | Credit-Pulse Normal HIGH: SF=100, DPP=2 | Connect with coin changer | ||||||
Credit-Pulse Normal LOW: SF=1, DPP=0 | Connect with ICT JPSTD converter board | |||||||
Pulse Mode (ICT104V Mode) | Other Mode | ICT104V Mode | ||||||
ON | OFF | |||||||
Other Mode | MDB Mode | |||||||
1 pulse / HRK 5 | OFF OFF | |||||||
2 pulses / HRK 5 | Reserved | OFF ON | ||||||
5 pulses / HRK 5 | ICT104U Mode | ON OFF | ||||||
10 pulses / HRK 5 | ICT104V Mode | ON ON |
This dip switch is located on the CPU board, remove the CPU board cover first.
[Diagram: CPU board with DIP switch location (1) indicated.]
Manufacturer Settings and Notes
After setting the dip switch for credit pulses, reset the bill acceptor.
Notes:
- (1) Please reset the bill acceptor after setting the dip switch.
- (2) Dip switches 1 to 5 are used only for pulse protocol.
- (3) Calibration card is needed.
- (4) Exchange Rate Settings (Only for Pulse, MDB):
- OFF: EUR 5 displays as HRK 25, EUR 10 as HRK 50, EUR 20 as HRK 100, EUR 50 as HRK 250.
- ON: EUR 5 displays as HRK 35, EUR 10 as HRK 70, EUR 20 as HRK 140, EUR 50 as HRK 350.