XBA-UAH10 Option Switch Settings
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Reject H 1 & 2 | ON | |||||||
Accept H 1 & 2 | OFF | |||||||
Reject H 5 & 10 | ON | |||||||
Accept H 5 & 10 | OFF | |||||||
Reject H 20 & 50 | ON | |||||||
Accept H 20 & 50 | OFF | |||||||
Reject H 100 & 200 | ON | |||||||
Accept H 100 & 200 | OFF | |||||||
Reject H 500 & 1000 | ON | |||||||
Accept H 500 & 1000 | OFF | |||||||
Disable Bill Reject 4 Times BA Stop By 30 Sec |
ON | |||||||
Enable Bill Reject 4 Times BA Stop By 30 Sec |
OFF | |||||||
Stack Banknote when Power-up | ON | |||||||
Reject Banknote when Power-up | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF |
This dip switch is located at the side of XBA.
[Diagram: Illustration showing the side of the XBA unit with a vertical strip of DIP switches labeled (2) DIP Switch, and an LED indicator light.]
XBA-UAH10 (Pulse/MDB/ICT106U/ccNet/ICT104V) Settings
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 | |
---|---|---|---|---|---|---|---|---|---|
Inhibit Active HIGH | ON | ||||||||
Inhibit Active LOW | OFF | ||||||||
Reserved | ON | ||||||||
Reserved | OFF | ||||||||
Reserved | ON | ||||||||
Reserved | OFF | ||||||||
Pulse Mode | MDB Mode | Scaling Factor (SF) = 100 Decimal Point Position (DPP) = 2 |
|||||||
ccNet Mode | Connect with ICT JPSTD 9600 Baud Rate |
||||||||
ICT104V Mode | Connect with coin change converter board 19200 Baud Rate |
||||||||
Other Mode | MDB Mode | OFF | OFF | ||||||
ICT106U Mode | OFF | ON | |||||||
ccNet Mode | ON | OFF | |||||||
ICT104V Mode | ON | ON | |||||||
1 pulse / H 1 (Dip 1: OFF) / H 5(Dip 1:ON) | MDB Mode | OFF | OFF | ||||||
ICT106U Mode | OFF | ON | |||||||
ccNet Mode | ON | OFF | |||||||
ICT104V Mode | ON | ON | |||||||
5 pulses / H 10 (Dip 1: OFF) / H 5(Dip 1:ON) | MDB Mode | OFF | OFF | ||||||
ICT106U Mode | OFF | ON | |||||||
ccNet Mode | ON | OFF | |||||||
ICT104V Mode | ON | ON | |||||||
10 pulses / H 1 (Dip 1: OFF) / H 5(Dip 1:ON) | MDB Mode | OFF | OFF | ||||||
ICT106U Mode | OFF | ON | |||||||
ccNet Mode | ON | OFF | |||||||
ICT104V Mode | ON | ON | |||||||
25 pulses / H 10 (Dip 1: OFF) / H 5(Dip 1:ON) | MDB Mode | OFF | OFF | ||||||
ICT106U Mode | OFF | ON | |||||||
ccNet Mode | ON | OFF | |||||||
ICT104V Mode | ON | ON |
This dip switch is located on the CPU board, remove the CPU board cover first.
[Diagram: Illustration showing the CPU board with a component labeled (1) DIP Switch. An arrow indicates it is covered by the CPU board cover. A detail view shows the DIP switch itself.]
Manufacture setting
After setting dip switch of the credit pulses, you should reset the bill acceptor again.
- Please reset the bill acceptor after set the dip switch.
- Dip switches 1 to 5 are only used for pulse protocol.
- Dip 1 turn OFF (MDB Mode : Reject UAH 500 & 1000).
- Calibration card is needed.
Currency Assign Data
Interface | Currency Assignment | ||||
---|---|---|---|---|---|
Pulse | MDB | ICT106U | ccNet | ICT104V | |
Bill value | H1 H1 H5 |
H1 H1 H5 |
H2 H2 H10 |
H5 H5 H20 |
H10 H10 H50 |
BV1 | H1 | H1 | H1 | H1 | H1 |
BV2 | H2 | H2 | H2 | H2 | H2 |
BV3 | H5 | H5 | H5 | H5 | H5 |
BV4 | H10 | H10 | H10 | H10 | H10 |
BV5 | H20 | H20 | H20 | H20 | H20 |
BV6 | H50 | H50 | H50 | H50 | H50 |
BV7 | H100 | H100 | H100 | H100 | H100 |
BV8 | H200 | H200 | H200 | H200 | H200 |
BV9 | H500 | H500 | H500 | H500 | H500 |
BV10 | H1000 | H1000 | H1000 | H1000 | H1000 |
Appendix
© 2016 International Currency Technologies Corporation
Vol. 5.0 Part Number: SWU5UAA50-R