SUBMITTAL DATA SHEET
High Wall Heat Pump System
System Information
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Approval:
Date:
Construction:
Unit #:
Drawing #:
Efficiency Ratings
Category | Cooling | Heating |
---|---|---|
SEER2 | 23.6 | HSPF2-4: 11.5 |
EER2 | 14 | COP: 3.72 |
Performance of Cooling
Rated Capacity (Btu/hr) | 9000 |
Min/Max Capacity (Btu/hr) | 3200~11500 |
Moisture Removal (L/h) | 1.37 |
Standard Operating Range (°F/°C) | -13 to 75 (-25 to 50) |
Conditions | Indoor: 80°F DB / 67°F WB; Outdoor: 95°F DB / 75°F WB |
Performance of Heating
Rated Capacity (Btu/hr) @ 47°F | 10000 |
Min/Max Capacity (Btu/hr) @ 47°F | 4000~12900 |
Rated Capacity (Btu/hr) @ 17°F | 7500 |
Capacity / COP @ 5°F | 7300 / 2.17 |
Max Capacity (Btu/hr) @ 5°F | 8400 |
Standard Operating Range (°F/°C) | -13 to 122 (-25 to 24) |
Conditions |
1. Indoor: 70°F DB / 60°F WB; Outdoor: 47°F DB / 43°F WB 2. Indoor: 70°F DB / 60°F WB; Outdoor: 17°F DB / 15°F WB 3. Indoor: 70°F DB / 60°F WB; Outdoor: 5°F DB / 5°F WB |
Indoor Unit Specifications
Parameter | Value |
---|---|
Indoor Air Flow (Turbo/H/M/L/Si) (CFM) | 367.9 / 317.8 / 214.8 / 129.5 / 67.7 |
Indoor Noise Level (Turbo/H/M/L/Si) (dBA) | 43.0 / 39.5 / 33.5 / 24.0 / 18.0 |
Dimension (W×D×H) (inch) | 31.57 x 7.44 x 11.69 |
Dimension (W×D×H) (mm) | 802×189×297 |
Package (W×D×H) (inch) | 36.02 x 16.34 x 14.37 |
Package (W×D×H) (mm) | 915×415×365 |
Net/Gross Weight (lbs) | 24.91 / 35.49 |
Net/Gross Weight (kg) | 11.3 / 16.1 |
A diagram illustrates the indoor unit's dimensions, labeled with Width (W), Depth (D), and Height (H). A table provides specific measurements in inches and millimeters for various models or capacities.
Outdoor Unit Specifications
Parameter | Value |
---|---|
Compressor Type | ROTARY |
Compressor Model | KSK103D33UEZ3 |
Refrigerant | R454B |
Refrigerant Oil Charge (mL) | 310 |
Refrigerant Oil | 5.65 |
Outdoor Air Flow (Max) (CFM) | 2100 |
Outdoor Noise Level (dBA) | 54 |
Dimension (W×D×H) (inch) | 30.12 x 11.93 x 21.85 |
Dimension (W×D×H) (mm) | 765×303×555 |
Package (W×D×H) (inch) | 36.22 x 16.54 x 27.56 |
Package (W×D×H) (mm) | 920×420×700 |
Net/Gross Weight (lbs) | 83.11 / 65.48 |
Net/Gross Weight (kg) | 37.7 / 29.7 |
A diagram presents the outdoor unit's dimensions, with labels for Width (W, W1), Depth (D), and Height (H), including a detailed view (DETAIL A) with scale. Measurements are provided in inches and millimeters.
Electrical Specifications
Parameter | Value |
---|---|
Power Supply | 115V, 60Hz, 1Ph |
System MCA | 18.0 |
Connection Wiring | 14#x4 |
System MOCP | 20 |
Compressor RLA | 14.0 |
Outdoor Fan Motor RLA | 0.6 |
Outdoor Fan Motor W | 34 |
Indoor Fan Motor RLA | 0.6 |
Indoor Fan Motor W | 35 |
System Power Input @ Cooling (W) | 643 (200 ~ 970) |
System Power Input @ Heating (W) | 788 (220 ~ 1090) |
MCA: Min. circuit amps (A) | |
MOCP: Max. over current protection (A) | |
RLA: Rated load amps (A) | |
W: Fan motor rated output (W) |
Piping Specifications
Parameter | Value |
---|---|
Throttle type (Indoor) | N/A |
Throttle type (Outdoor) | EXV |
Liquid Size | 6.35mm (1/4in) |
Gas Size | 9.52mm (3/8in) |
Max. Piping Length (ft/m) | 82 (25) |
Max. Height Difference (ft/m) | 49.20 (15) |
Max. Pre-charged Length (ft/m) | 24.6 (7.5) |
Refrigerant Pre-charged Amount (oz/g) | 30.34 (0.86) |
Additional Charge of Refrigerant (oz/ft) / (g/m) | 0.16 (15) |
Connection Method | Flared |
Installation Notes
Indoor Unit Installation
An illustration demonstrates installation options for the indoor unit's piping exit, showing four possible directions relative to the wall hole and mounting plate. A note advises that the wall hole should be 3-1/2 inches (90mm) if the gas side connective pipe is 5/8 inch (16mm) or larger.
Outdoor Unit Installation
An illustration outlines the required clearance space around the outdoor unit for optimal performance. It specifies minimum clearances: 20 inches (500mm) when front and sides are clear, 4 inches (100mm) on the sides, and 14 inches (350mm) at the rear. A checkmark symbol ? indicates that the unit meets these spatial requirements.
Features
- Indoor unit TU1 copper coil
- Humidity control
- 1~100% fan speed setting
- WiFi capability: through WiFi dongle or wired controller with built-in WiFi
- OTA (Over-The-Air updates) by using WiFi dongle
- Multiple control options available:
- Two way communication wired controller: 120N(X6)
- Two way communication wired controller with built-in WiFi: 120N(X6W)
- Infrared wired controller: 120L
- Wireless remote controller
- Third-Party 24V Thermostat* (Note: *24V interface is required.)
Product Images and Certifications
A visual representation shows the indoor unit of the heat pump system, typically wall-mounted, with a slim, modern design. A visual representation shows the outdoor unit (condenser) of the heat pump system, featuring a fan grill and housing for the compressor and components. The document displays several certification logos: ALIDI PCERTIFIED, ETL LISTED, and ENERGY STAR.