High Wall Heat Pump System Submittal Data Sheet

Efficiency

Rating Cooling Heating
SEER2 21.3 -
EER2 10.8 -
HSPF2-4 - 9.2
COP - 3.34

Performance of Cooling

Rated Capacity: 12000 Btu/hr

Min/Max Capacity: 2700~13800 Btu/hr

Moisture Removal: 1.4 L/h

Standard Operating Range: 5~122°F (-15~50°C)

Conditions: Indoor: 80°F DB / 67°F WB; Outdoor: 95°F DB / 75°F WB

Performance of Heating

@ 47°F Rated: 12000 Btu/hr

@ 47°F Min/Max Capacity: 4200~14100 Btu/hr

@ 17°F Rated: 8300 Btu/hr

@ 5°F Rated: Capacity / COP: 8000 Btu/hr / 1.80

@ 5°F Max Capacity: 8000 Btu/hr

Standard Operating Range: 5~75°F (-15~24°C)

Conditions:

Indoor Specification

Parameter Value
Indoor Air Flow (Turbo/H/M/L/Si) 347.3 / 294.3 / 194.2 / 153.0 / - CFM
Indoor Noise Level (Turbo/H/M/L/Si) 46 / 41 / 35 / 24 / 18.5 dBA
Dimension (W×D×H) 31.57 x 7.87 x 11.61 inch (802.0×200.0×295.0 mm)
Package: 34.45 x 11.22 x 14.96 inch (875×285×380 mm)
Net/Gross Weight 18.96 / 25.13 lbs
8.6 / 11.4 kg

Outdoor Specification

Parameter Value
Compressor Type ROTARY
Compressor Model KSN98D64UFZ3
Refrigerant R454B
Refrigerant Oil Charge 300 mL
Refrigerant Oil VG74
Outdoor Air Flow (Max) 1235.3 CFM
Outdoor Noise Level 53.0 dBA
Dimension (W×D×H) 30.12 x 11.93 x 21.85 inch (765.0×303.0×555.0 mm)
Package: 34.92 x 13.27 x 24.02 inch (887×337×610 mm)
Net/Gross Weight 59.08 / 64.37 lbs
26.8 / 29.2 kg

Electrical

Parameter Value
Power Supply 208/230V, 60Hz, 1Ph
System MCA 13.0 A
Connection Wiring 14#x4
System MOCP 15 A
Compressor RLA 7.5 A
Outdoor Fan Motor RLA 0.4 A
Outdoor Fan Motor W 34 W
Indoor Fan Motor RLA 0.4 A
Indoor Fan Motor W 30 W
System Power Input @ Cooling 1111 W (220~1430 W)
System Power Input @ Heating 1053 W (235~1310 W)
MCA (Min. circuit amps) [See System MCA]
MOCP (Max. over current protection) [See System MOCP]
W (Fan motor rated output) [See Motor W values]

Piping

Parameter Value
Throttle type (Indoor) N/A
Throttle type (Outdoor) Capillary
Liquid Size 6.35mm (1/4in)
Gas Size 9.52mm (3/8in)
Max. Piping Length 82.00 ft (25 m)
Max. Height Difference 49.20 ft (15 m)
Max. Pre-charged Length 24.6 ft (7.5 m)
Refrigerant Pre-charged Amount 24.69 oz (0.7 kg)
Additional Charge of Refrigerant 0.16 oz/ft (15 g/m)
Connection Method Flared

Features

*24V interface is required.

Diagram Description: Indoor Unit Dimensions

This section describes the dimensions of the indoor unit. It includes views showing the Width (W), Depth (D), and Height (H). A table lists specific dimensions for different capacities (6K~9K, 9K~12K, 18K, 18K~24K, 30K~36K) in both inches and millimeters for Width, Depth, and Height.

Capacity Body Code W (inch/mm) D (inch/mm) H (inch/mm)
6K~9K A 28-3/4in / 729mm 7-7/8in / 200mm 11-1/2in / 292mm
9K~12K B 31-5/8in / 802mm 7-7/8in / 200mm 11-5/8in / 295mm
18K C 38-1/4in / 971mm 9in / 228mm 12-5/8in / 321mm
18K~24K D 42-5/8in / 1082mm 9-1/4in / 234mm 13-1/4in / 337mm
30K~36K F 49-5/8in / 1259mm 11-1/8in / 283mm 14-1/4in / 362mm

Indoor unit dimensions (WxH): 31.7in(806mm) x 11.65in(296mm) is also noted.

Diagram Description: Installation Instruction (Indoor Unit)

This section provides guidance on selecting the installation location for the indoor unit. It shows a diagram illustrating recommended clearances and placement. A key diagram shows a wall plate with mounting holes and dimensions: 6 inches (15cm) height, 4-3/4 inches (12cm) from the top and bottom edges. The horizontal mounting span is 70 inches (180cm). Notes indicate that the piping exit direction should be chosen based on the wall hole position relative to the mounting plate, offering four options. Another note specifies that if the gas side connective pipe is 5/8 inch (16mm) or larger, the wall hole should be 3-1/2 inches (90mm). The diagram for the indoor unit's rear shows mounting holes and dimensions (W x H), with a note regarding the gas side connective pipe size and wall hole diameter.

Diagram Description: Outdoor Unit Dimensions

This section details the dimensions of the outdoor unit. It includes front, side, and top views, indicating Width (W, W1, W3), Depth (D), and Height (H). Specific measurements are provided in inches and millimeters. A detail view (DETAIL A, SCALE 1:2) shows connection points and dimensions (A, B, C, D, R5).

View Dimension Value (inch/mm)
Front/Top W3 30-7/8in / 784mm
Front/Top W 30-1/8in / 765mm
Front/Top W1 32-7/8in / 835mm
Front/Top A 17-3/4in / 452mm
Side D 11-7/8in / 303mm
Side H 21-7/8in / 555mm
Side C 12-3/8in / 314mm
Side B 11-1/4in / 286mm
Side 3/4in (18mm) [Dimension reference]
Side 3in (76mm) [Dimension reference]
Side 1-1/4in (32mm) [Dimension reference]
Detail A R5 2-3/8in (61.6mm)

Diagram Description: Installation Instruction (Outdoor Unit)

This section outlines the installation clearance requirements for the outdoor unit. Diagrams show recommended spacing from walls and other obstructions. Clearances are indicated with arrows and text:

A checkmark symbol [☑] indicates that the unit meets all spatial requirements shown in the Installation Clearance Requirements above.

PDF preview unavailable. Download the PDF instead.

blueridgebxs2a12wmspecificationssheet 8ED7B90E-5790-45D4-9522-FC30949877D9 Google Sheets

Related Documents

Preview Blueridge XL1 CDH Slim Duct Regular System Submittal Data Sheet
Technical specifications and installation details for the Blueridge XL1 CDH Slim Duct Regular System, including efficiency, performance, electrical, and piping data.
Preview Blueridge XS5 CC 4-Way Cassette Heat Pump System Submittal Data Sheet
Comprehensive submittal data sheet for the Blueridge XS5 CC 4-Way Cassette Heat Pump System, featuring R454B refrigerant. Includes detailed specifications, performance data for cooling and heating, electrical requirements, piping information, and installation clearance guidelines.
Preview Blueridge BM18MCD Duct Heat Pump Air Handler Submittal Data Sheet
Technical specifications and dimensions for the Blueridge BM18MCD Duct Heat Pump Air Handler indoor unit, including airflow, noise levels, and physical measurements.
Preview Blueridge BMKH2420LM Series: Specifications and Certifications
Comprehensive technical specifications, performance data, dimensions, and installation clearances for the Blueridge BMKH2420LM series of ductless mini-split heat pump systems.
Preview Blueridge BMM18C Multi Zone Heat Pump Submittal Data Sheet | Specifications
Detailed submittal data sheet for the Blueridge BMM18C Multi Zone Heat Pump, including system performance, electrical, refrigerant, and dimensional specifications. Features AHRI certification and ENERGY STAR rating.
Preview Blueridge 19 SEER Single Zone Ductless Mini-Split Specifications | BM09Y18, BM12Y19, BM18Y19, BM24Y17
Detailed specifications for Blueridge Standard Single Zone 19 SEER Ductless Mini-Split systems, covering model numbers, cooling and heating capacities, operating temperatures, dimensions, electrical requirements, and component details.
Preview Blueridge BMKH1824 Series Mini-Split Heat Pump: Specifications, Ratings, and Certifications
Detailed specifications, performance data, what's in the box, and certifications for the Blueridge BMKH1824 series mini-split heat pump systems. Includes AHRI and ENERGY STAR ratings, unit dimensions, and installation clearances.
Preview Blueridge PTAC Series Owner's Manual: Installation, Operation, and Maintenance
Comprehensive owner's manual for the Blueridge PTAC Series Packaged Terminal Air Conditioner/Heat Pump, covering safety precautions, installation, operation, customization, care, maintenance, and troubleshooting.