SUBMITTAL DATA SHEET
Location: [Not Specified]
Engineer: [Not Specified]
Submitted to: [Not Specified]
Submitted by: [Not Specified]
Reference: [Not Specified]
Certifications: ARI CERTIFIED, ENERGY STAR, UL, ETL
EFFICIENCY
Cooling | Heating | |
---|---|---|
SEER2 | 16.0 | HSPF2-4 10.0 |
EER2 | 10.0 | COP 3.37 |
PERFORMANCE OF COOLING
Cooling (Btu/hr)
Rated Capacity | 29,000 |
Min/Max Capacity | 13,900~37,900 |
Moisture Removal(L/h) | 3.7 |
Standard Operating Range (°F/°C) | -22~122 (-30~50) |
Rated Cooling Conditions: | Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB |
PERFORMANCE OF HEATING
Heating (Btu/hr)
1. @ 47°F Rated | 32,000 |
2. @ 47°F Min/Max Capacity | 13,00~40,000 |
3. @ 17°F Rated | 25,000 |
4. @ 5°F Rated: Capacity / COP | 33,000 / 1.9 |
5. @ 5°F Max: Capacity | 33,000 |
Standard Operating Range (°F/°C) | -22~75 (-30~24) |
1. Rated Heating Conditions: | Indoor: 70°F DB/60°F WB Outdoor: 47°F DB/43°F WB |
2. Rated Heating Conditions: | Indoor: 70°F DB/60°F WB Outdoor: 17°F DB/15°F WB |
3. Heating Conditions, Compressor Operating at Max. Frequency | Indoor: 70°F DB/60°F WB Outdoor: 5°F DB/5°F WB |
INDOOR SPECIFICATION
Dimension (W×D×H) | 17-1/2 x 21 x 23-1/2 inches (445 x 533 x 599 mm) |
Package (W×D×H) | 20-1/2 x 26-1/8 x 26-3/8 inches (520 x 665 x 670 mm) |
Net/Gross Weight | 59.5/68 lbs (27/30.9 kg) |
OUTDOOR SPECIFICATION
Compressor Type | ROTARY |
Compressor Model | MTH356UKRC8FQL |
Refrigerant | R454B |
Refrigerant Oil Charge(mL) | 1300 |
Refrigerant Oil | HAF68D1A |
Outdoor Air Flow (Max) (CFM) | 3,002 |
Outdoor Noise Level (dBA) | 64 |
Dimension (W×D×H) | 37-1/4 x 16-1/8 x 31-7/8 inches (946 x 410 x 810 mm) |
Package (W×D×H) | 42-7/8 x 19-5/8 x 34-7/8 inches (1090 x 500 x 885 mm) |
Net/Gross Weight | 164/175 lbs (74.4/79.2 kg) |
ELECTRICAL
Indoor Power Supply | 24V,60Hz, 1Ph |
Indoor MCA 115V/(208/230V) | / |
Indoor MOP | / |
Outdoor Power Supply | 208/230,60Hz, 1Ph |
Outdoor MCA | 29.5 A |
Outdoor MOP | 30 A |
Communication Wiring | AWG 20-2 |
Compressor RLA | 22.4 A |
Outdoor Fan Motor RLA | 1.5 A |
Outdoor Fan Motor W | / |
Indoor Fan Motor RLA | / |
Indoor Fan Motor W | / |
System Power Input @ Cooling (W) | 2900 (1,160 ~ 3,740) |
System Power Input @ Heating (W) | 2780 (1,088 ~ 3,482) |
MCA: Min. circuit amps (A) | [Value not explicitly listed for outdoor, but MCA is listed] |
MOCP: Max. over current protection (A) | [Value not explicitly listed for outdoor, but MOP is listed] |
RLA: Rated load amps (A) | [Value not explicitly listed for outdoor, but RLA is listed] |
W: Fan motor rated output (W) | [Value not explicitly listed for outdoor, but W is listed] |
PIPING
Throttle type(Indoor) | EXV |
Throttle type(Outdoor) | EXV |
Liquid Size | 9.52mm (3/8in) |
Gas Size | 19mm (3/4in) |
Max. Piping Length(ft/m) | 164 (50) |
Max. Height Difference(ft/m) | 82 (25) |
Max. Pre-charged Length(ft/m) | 24.6 (7.5) |
Refrigerant Pre-charged Amount (oz/kg) | 105.82 (3) |
Additional Charge of Refrigerant((oz/ft)/(g/m)) | 0.7 (65) |
Connection Method | Flared |
Indoor Unit Dimensions
Diagrams illustrating the dimensions of the indoor unit. Includes front, side, and top views, showing key measurements labeled A through F. A table provides specific dimensions (Height, Width, Supply Air Opening Width, Return Air Opening Width, Condensate Drains Height, Liquid Line Height) in inches and millimeters for various models (MVBM-24B18T3N10, MVBM-24A18T3N10, MVBM-36A24T4N10, MVBM-36B24T4N10, MVBM-36C24T4N10, MVBM-60D28T6N10).
Dimension | Model | MVBM-24B18T3N10 | MVBM-24A18T3N10 | MVBM-36A24T4N10 | MVBM-36B24T4N10 | MVBM-36C24T4N10 | MVBM-60D28T6N10 |
---|---|---|---|---|---|---|---|
inch | mm | inch | mm | inch | mm | inch | mm | inch | mm | inch | mm | ||
A: Model Height | 18 | 457 | 18 | 457 | 23-5/16 | 592 | 23-9/16 | 599 | 24 | 611 | 28 | 711 | |
B: Model Width | 17-1/2 | 445 | 14-1/2 | 368 | 14-1/2 | 368 | 17-1/2 | 445 | 21 | 534 | 24-1/2 | 622 | |
C: Supply Air Opening Width | 16-3/16 | 411 | 13-1/4 | 336 | 13-1/4 | 336 | 16-3/16 | 411 | 19-3/4 | 502 | 23-1/4 | 591 | |
D: Return Air Opening Width | 15/16 | 380 | 15/16 | 303 | 15/16 | 303 | 15/16 | 380 | 19-1/2 | 498 | 23-1/8 | 587 | |
E: Condensate Drains Height | 1-7/16 | 38 | 1-7/16 | 38 | 1-7/16 | 38 | 1-7/16 | 38 | 2-3/16 | 55 | 2-3/16 | 55 | |
F: Liquid Line Height | 11-3/8 | 290 | 11-3/8 | 290 | 17-15/16 | 455 | 16-3/8 | 417 | 17-1/2 | 445 | 21-7/16 | 545 |
Outdoor Unit Dimensions
Diagrams showing the external dimensions of the outdoor unit from multiple angles (front, side, top). Includes measurements for overall width, depth, and height, as well as details for pipe connections and mounting points.
Installation Instruction For Outdoor Unit
Diagram illustrating required clearances for the outdoor unit installation. Specifies minimum distances: 20 inches (500mm) or more from the front and sides when any two sides (left, right, rear) are clear; 4 inches (100mm) or more from the sides and rear. Also indicates 4 inches (100mm) or more clearance from the front and sides when the unit is clear.
✓ Meets all spatial requirements shown in Installation Clearance Requirements above.
Features
- Multi-position installation: horizontal (left or right), vertical (up or down)
- Aluminum Coil
- R454B refrigerant sensor
- Easy Maintenance
- Multiple control options available:
- Two way communication wired controller with built-in WiFi: 120N(X6W)
- Third-Party 24V Thermostat