logo PPI

UniLog Pro / UniLog Pro Plus karo CIM
Versi Piranti Lunak PC Perekam Data Proses Universal

UniLog Pro Suhu Data Logger

Manual Operasi
Manual singkat iki utamané dimaksudaké kanggo referensi cepet sambungan kabel lan searching parameter. Kanggo rincian liyane babagan operasi lan aplikasi; mangga log on www.ppiindia.net

 

OPERATOR PARAMETER
Paramèter Setelan (Nilai Default)
'Mulai' Command kanggo Batch Rekaman

(Kasedhiya yen Rekaman Kumpulan dipilih)

Ora Ya
BATCH START >> NO  
'Stop' Command kanggo Batch Rekaman (Kasedhiya yen Rekaman Kumpulan dipilih)  Ora Ya
BATCH STOP>> NO  

KONFIGURASI SUPERVISOR

PPI UniLog Pro Temperatur Data Logger

Cathetan: AII Parameter liyane ana ing SUPERVISORY CONFIGURATION

SETTING weker
Paramèter Setelan (Nilai Default)
Jeneng Saluran kanggo Setelan Weker

PILIH CHANNEL>>

Saluran-1

Jeneng pangguna sing ditetepake utawa standar kanggo saluran-1 nganti saluran-8 / 16 (Default: NA)
Pilih Weker

PILIH ALARM >> AL1

AL1, AL2, AL3, AL4

(Opsi sing kasedhiya nyata gumantung saka jumlah Weker sing disetel saben saluran

kaca konfigurasi weker)

Jinis Alarm

AL1 JENIS>> Ora ana

Ora Ana Proses Kurang Precess Dhuwur (Default: Ora Ana)
Setpoint Weker

AL1 SETPOINT>> 0

Min. kanggo Max. saka sawetara jinis input sing dipilih (Default: 0)
Histeresis weker

AL1 HISTERESIS >> 2

1 nganti 3000 or

0.1 nganti 3000.0

(Default: 2 or 2.0)

Weker Ngalangi

AL1 INHIBIT >> Ya

Ora Ya

(Default: Ora)

KONFIGURASI piranti
Paramèter Setelan (Nilai Default)
Wektu Nganyari Saluran ing Mode Pindai Otomatis

SCAN RATE>>

3

 

1 sek. iki 99 Sec. (Default: 3 Sec.)

piranti Nomer Idhentifikasi

ID RECORDER>>

2

 

1 kanggo127

(Default: 1)

Pilih Total Jumlah Saluran

TOTAL SALURAN >>

16

8

16

(Default: 16)

Busak Kabeh sing disimpen Cathetan

Mbusak cathetan>>

Ora

 

Ora Ya

(Default: Ora)

 
KONFIGURASI CHANNEL
Paramèter Setelan (Nilai Default)
Pilih Jeneng Saluran

PILIH SALURAN >> Saluran-1

Jeneng pangguna sing ditetepake utawa standar kanggo saluran-1 menyang saluran - 8 / 16

(Default: NA)

Skip Channel kanggo Tampilan

SKIP >> Ora

Ora Ya

(Default: Ya)

Tipe Input Sinyal

TIPE INPUT>> Tipe K (Cr-Al)

Rujuk Tabel 2 (Default : Tipe K (Cr-Al)
Resolusi tampilan kanggo PV diukur

RESOLUSI>> 0.1 Unit

1 Unit

0.1 Unit

0.01 Unit *

0.001 Unit * (Default: 0.1 Unit)

(* kanggo 4-20mA)

Tampilan Unit kanggo diukur PV

UNIT>> °C

 

Rujuk Tabel 1 (Default: °C)

Range Low (kanggo 4-20mA) RANGE RENDAH>> 0 -19999 nganti 30000 Cacah kanthi Resolusi sing Dipilih (Default: 0.0)
Range Dhuwur

(kanggo 4-20mA) RANGE HIGH>> 1000

-19999 nganti 30000 Cacah kanthi Resolusi sing Dipilih (Default: 100.0)
Aplikasi Klip Ngisor ing PV sing Ditampilake

(kanggo 4-20mA) LOW CLIPPING>> Pateni

 

Pateni Aktifake

(Default: Pateni)

Tingkat Klip Ngisor Prasetel

(kanggo 4-20mA) LOW CLIP VAL>> 0.0

 

-19999 nganti 30000

(Default: 0)

Aplikasi Klip Ndhuwur ing PV sing ditampilake

(kanggo 4-20mA) Kliping dhuwur>> Pateni

 

Pateni Aktifake

(Default: Pateni)

Prasetel Level Klip Ndhuwur

(kanggo 4-20mA) VAL Klip dhuwur>> 100.0

 

-19999 nganti 30000

(Default: 100.0)

Nol Offset

NOL OFFSET>> 0

-1999 / 3000 or

-1999.9 / 3000.0

(Default: 0)

KONFIGURASI weker
Paramèter Setelan (Nilai Default)
Weker Saben Saluran

ALARM / CHAN >> 4

1 nganti 4

(Default: 4)

Relay-1 Logika

Relay-1 LOGIKA >> Normal

Normal Mundur (Default: Normal)
Relay-2 Logika

Relay-2 LOGIKA >> Normal

Normal Mundur (Default: Normal)
 
KONFIGURASI RECORDER
Paramèter Setelan (Nilai Default)
Normal Interval Rekaman

INTERVAL NORMAL>> 0:00:30

0:00:00 (H:MM:SS)

nganti 2:30:00 (H:MM:SS)

(Default: 0:00:30)

Ngrekam Zoom Interval

ZOOM INTERVAL>> 0:00:01

0:00:00 (H:MM:SS)

nganti 2:30:00 (H:MM:SS)

(Default: 0:00:01)

Rekam Generasi ing Toggle Status Weker

ALARM TOGGLE REC >> Pateni

 

Pateni Aktifake

(Default: Aktifake)

Pilih Mode Rekaman

MODE RAKAMAN >> Terus

Batch terus-terusan

(Default: Terus-terusan)

Interval Wektu kanggo Rekaman Kumpulan (mung kanggo mode Batch)

WAKTU BATCH>> 1.00

0:01 (HH:MM)

nganti 250:00 (HHH:MM)

(Default: 1:00)

 
SETTING RTC
Paramèter Setelan
Setel Wektu Jam (HH:MM)

WAKTU (HH:MM)>>

15:53

 

0.0 kanggo 23:59

Setel Tanggal Tanggalan

TANGGAL >> 23

 

1 nganti 31

Setel Tanggalan Wulan

WULAN >> 11

 

1 nganti 12

Setel Taun Tanggalan

TAHUN >> 2011

 

2000 nganti 2099

 
UTILITAS
Paramèter Setelan
Master Lock Aktifake Pateni

LOCK>> No UNLOCK>> No

 

 

Ora Ya

UIM Default

UIM DEFAULT >> No

Ora Ya
CIM Default

CIM DEFAULT >> No

 Ora Ya
Nggawe CIM & UIM Kompatibel

CPY CIM TO UIM>> Ora CPY UIM TO CIM>> No

Ora Ya
TABEL - 1
Pilihan Katrangan
°C Derajat Celcius
°F Gelar Fahrenheit
(ora ana) Ora Ana Unit (Kosong)
°K Derajat Kelvin
EU Unit Teknik
% Persentage
Pa Pascals
Mpa Mpascals
kPa Kpascals
bar bar
mbar Milli bar
psi PSI
kg/sq.cm kg/cm2
mmH2O mm gauge banyu
ingH2O Pengukur banyu inci
mmHg mm merkuri
Torr Torr
liter/jam Liter saben jam
liter / min Liter saben menit
%RH % Kelembapan Relatif
%O2 %oksigen
%CO2 % Karbon dioksida
%CP % Potensi Karbon
V Volt
A Amps
mA Milli Amps
mV Mili Volt
ohm Ohm
ppm Bagean saben yuta
rpm Revolusi saben menit
mSec Mili detik
Sek Detik
min menit
jam jam
PH PH
%PH %PH
mil/jam Mil saben jam
mg Mili gram
g Gram
kg Kilo gram
TABEL - 2
Pilihan Range (Min. nganti Maks.) Resolusi
PPI UniLog Pro Temperatur Data Logger - lambang  

0 nganti +960°C / +32 nganti +1760°F

 

 

 

 

 

 

 

 

 

Tetep 1°C / 1°F

PPI UniLog Pro Temperatur Data Logger - lambang 1  
PPI UniLog Pro Temperatur Data Logger - lambang 3  

PPI UniLog Pro Temperatur Data Logger - lambang 5

 

0 nganti +1771°C / +32.0 nganti +3219°F

PPI UniLog Pro Temperatur Data Logger - lambang 6  

0 nganti +1768°C / +32 nganti +3214°F

PPI UniLog Pro Temperatur Data Logger - lambang 8  
PPI UniLog Pro Temperatur Data Logger - lambang 9  
PPI UniLog Pro Temperatur Data Logger - lambang 10 Reserved kanggo jinis Thermocouple khusus pelanggan sing ora kadhaptar ing ndhuwur.
PPI UniLog Pro Temperatur Data Logger - lambang 11 -199 nganti +600°C / -328 nganti +1112°F

199.9 kanggo             or          iki 1112.0 ° F

600.0°C / -328.0

Pangguna sing bisa disetel 1°C / 1°F

utawa 0.1°C / 0.1°F

 

 

 

PPI UniLog Pro Temperatur Data Logger - ikon14

 

 

 

 

19999 kanggo +30000 unit Pangguna settable 1 / 0.1 / 0.01/

0.001 ing

ID SETTING kanggo luwih saka 1 CIM
Ditrapake mung kanggo UNILOG PRO PLUS

PPI UniLog Pro Temperatur Data Logger - anjir

LAPORAN PANEL FRONT

PPI UniLog Pro Temperatur Data Logger - gambar 1

Simbol

Kunci Fungsi
PPI UniLog Pro Temperatur Data Logger - lambang 15 PAGE Pencet kanggo mlebu utawa metu saka mode persiyapan.
PPI UniLog Pro Temperatur Data Logger - lambang 17  

TURUN

Pencet kanggo nyuda nilai parameter. Pencet sapisan nyuda nilai kanthi siji count; terus dipencet nyepetake owah-owahan.
PPI UniLog Pro Temperatur Data Logger - lambang 18  

UP

Pencet kanggo nambah nilai parameter. Pencet sapisan nambah nilai kanthi siji count; terus dipencet nyepetake owah-owahan.
PPI UniLog Pro Temperatur Data Logger - lambang 20 ENTER Pencet kanggo nyimpen nilai parameter sing disetel lan kanggo nggulung menyang parameter sabanjure ing PAGE.

SAMBUNGAN LISTRIK
MODUL ANTARMUKA PENGGUNA (UIM) 

PPI UniLog Pro Temperatur Data Logger - gambar 20

PORT KOMUNIKASI KAnggo INTERFACING KARO CIM(S)
Ditrapake mung kanggo UNILOG PLUS
PPI UniLog Pro Temperatur Data Logger - gambar 10

SETTING JUMPER
MODUL ANTARA WAJAH SALURAN INPUT (CIM)
PPI UniLog Pro Temperatur Data Logger - gambar 14PPI UniLog Pro Temperatur Data Logger - gambar 15

SETTING JUMPER
MODUL ANTARA WAJAH SALURAN INPUT (CIM)
PPI UniLog Pro Temperatur Data Logger - gambar 25

SAMBUNGAN LISTRIK
MODUL ANTARMUKA SALURAN (CIM) 
PPI UniLog Pro Temperatur Data Logger - gambar 18

 

 

 

 

Dokumen / Sumber Daya

PPI UniLog Pro Temperatur Data Logger [pdf] Instruksi Manual
UniLog Pro Temperatur Data Logger, UniLog Pro, Temperatur Data Logger, Data Logger, Logger

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *