UniLog Pro / UniLog Pro Plus karo CIM
Versi Piranti Lunak PC Perekam Data Proses Universal
UniLog Pro Suhu Data Logger
Manual Operasi
Manual singkat iki utamané dimaksudaké kanggo referensi cepet sambungan kabel lan searching parameter. Kanggo rincian liyane babagan operasi lan aplikasi; mangga log on www.ppiindia.net
OPERATOR PARAMETER | |
Paramèter | Setelan (Nilai Default) |
'Mulai' Command kanggo Batch Rekaman
(Kasedhiya yen Rekaman Kumpulan dipilih) |
Ora Ya |
BATCH START >> NO | |
'Stop' Command kanggo Batch Rekaman (Kasedhiya yen Rekaman Kumpulan dipilih) | Ora Ya |
BATCH STOP>> NO |
KONFIGURASI SUPERVISOR
Cathetan: AII Parameter liyane ana ing SUPERVISORY CONFIGURATION
SETTING weker | |
Paramèter | Setelan (Nilai Default) |
Jeneng Saluran kanggo Setelan Weker
PILIH CHANNEL>> Saluran-1 |
Jeneng pangguna sing ditetepake utawa standar kanggo saluran-1 nganti saluran-8 / 16 (Default: NA) |
Pilih Weker
PILIH ALARM >> AL1 |
AL1, AL2, AL3, AL4
(Opsi sing kasedhiya nyata gumantung saka jumlah Weker sing disetel saben saluran kaca konfigurasi weker) |
Jinis Alarm
AL1 JENIS>> Ora ana |
Ora Ana Proses Kurang Precess Dhuwur (Default: Ora Ana) |
Setpoint Weker
AL1 SETPOINT>> 0 |
Min. kanggo Max. saka sawetara jinis input sing dipilih (Default: 0) |
Histeresis weker
AL1 HISTERESIS >> 2 |
1 nganti 3000 or
0.1 nganti 3000.0 (Default: 2 or 2.0) |
Weker Ngalangi
AL1 INHIBIT >> Ya |
Ora Ya
(Default: Ora) |
KONFIGURASI piranti | |
Paramèter | Setelan (Nilai Default) |
Wektu Nganyari Saluran ing Mode Pindai Otomatis
SCAN RATE>> 3 |
1 sek. iki 99 Sec. (Default: 3 Sec.) |
piranti Nomer Idhentifikasi
ID RECORDER>> 2 |
1 kanggo127 (Default: 1) |
Pilih Total Jumlah Saluran
TOTAL SALURAN >> 16 |
8
16 (Default: 16) |
Busak Kabeh sing disimpen Cathetan
Mbusak cathetan>> Ora |
Ora Ya (Default: Ora) |
KONFIGURASI CHANNEL | |
Paramèter | Setelan (Nilai Default) |
Pilih Jeneng Saluran
PILIH SALURAN >> Saluran-1 |
Jeneng pangguna sing ditetepake utawa standar kanggo saluran-1 menyang saluran - 8 / 16
(Default: NA) |
Skip Channel kanggo Tampilan
SKIP >> Ora |
Ora Ya
(Default: Ya) |
Tipe Input Sinyal
TIPE INPUT>> Tipe K (Cr-Al) |
Rujuk Tabel 2 (Default : Tipe K (Cr-Al) |
Resolusi tampilan kanggo PV diukur
RESOLUSI>> 0.1 Unit |
1 Unit
0.1 Unit 0.01 Unit * 0.001 Unit * (Default: 0.1 Unit) (* kanggo 4-20mA) |
Tampilan Unit kanggo diukur PV
UNIT>> °C |
Rujuk Tabel 1 (Default: °C) |
Range Low (kanggo 4-20mA) RANGE RENDAH>> 0 | -19999 nganti 30000 Cacah kanthi Resolusi sing Dipilih (Default: 0.0) |
Range Dhuwur
(kanggo 4-20mA) RANGE HIGH>> 1000 |
-19999 nganti 30000 Cacah kanthi Resolusi sing Dipilih (Default: 100.0) |
Aplikasi Klip Ngisor ing PV sing Ditampilake
(kanggo 4-20mA) LOW CLIPPING>> Pateni |
Pateni Aktifake (Default: Pateni) |
Tingkat Klip Ngisor Prasetel
(kanggo 4-20mA) LOW CLIP VAL>> 0.0 |
-19999 nganti 30000 (Default: 0) |
Aplikasi Klip Ndhuwur ing PV sing ditampilake
(kanggo 4-20mA) Kliping dhuwur>> Pateni |
Pateni Aktifake (Default: Pateni) |
Prasetel Level Klip Ndhuwur
(kanggo 4-20mA) VAL Klip dhuwur>> 100.0 |
-19999 nganti 30000 (Default: 100.0) |
Nol Offset
NOL OFFSET>> 0 |
-1999 / 3000 or
-1999.9 / 3000.0 (Default: 0) |
KONFIGURASI weker | |
Paramèter | Setelan (Nilai Default) |
Weker Saben Saluran
ALARM / CHAN >> 4 |
1 nganti 4
(Default: 4) |
Relay-1 Logika
Relay-1 LOGIKA >> Normal |
Normal Mundur (Default: Normal) |
Relay-2 Logika
Relay-2 LOGIKA >> Normal |
Normal Mundur (Default: Normal) |
KONFIGURASI RECORDER | |
Paramèter | Setelan (Nilai Default) |
Normal Interval Rekaman
INTERVAL NORMAL>> 0:00:30 |
0:00:00 (H:MM:SS)
nganti 2:30:00 (H:MM:SS) (Default: 0:00:30) |
Ngrekam Zoom Interval
ZOOM INTERVAL>> 0:00:01 |
0:00:00 (H:MM:SS)
nganti 2:30:00 (H:MM:SS) (Default: 0:00:01) |
Rekam Generasi ing Toggle Status Weker
ALARM TOGGLE REC >> Pateni |
Pateni Aktifake (Default: Aktifake) |
Pilih Mode Rekaman
MODE RAKAMAN >> Terus |
Batch terus-terusan
(Default: Terus-terusan) |
Interval Wektu kanggo Rekaman Kumpulan (mung kanggo mode Batch)
WAKTU BATCH>> 1.00 |
0:01 (HH:MM)
nganti 250:00 (HHH:MM) (Default: 1:00) |
SETTING RTC | |
Paramèter | Setelan |
Setel Wektu Jam (HH:MM)
WAKTU (HH:MM)>> 15:53 |
0.0 kanggo 23:59 |
Setel Tanggal Tanggalan
TANGGAL >> 23 |
1 nganti 31 |
Setel Tanggalan Wulan
WULAN >> 11 |
1 nganti 12 |
Setel Taun Tanggalan
TAHUN >> 2011 |
2000 nganti 2099 |
UTILITAS | |
Paramèter | Setelan |
Master Lock Aktifake Pateni
LOCK>> No UNLOCK>> No |
Ora Ya |
UIM Default
UIM DEFAULT >> No |
Ora Ya |
CIM Default
CIM DEFAULT >> No |
Ora Ya |
Nggawe CIM & UIM Kompatibel
CPY CIM TO UIM>> Ora CPY UIM TO CIM>> No |
Ora Ya |
TABEL - 1 | |
Pilihan | Katrangan |
°C | Derajat Celcius |
°F | Gelar Fahrenheit |
(ora ana) | Ora Ana Unit (Kosong) |
°K | Derajat Kelvin |
EU | Unit Teknik |
% | Persentage |
Pa | Pascals |
Mpa | Mpascals |
kPa | Kpascals |
bar | bar |
mbar | Milli bar |
psi | PSI |
kg/sq.cm | kg/cm2 |
mmH2O | mm gauge banyu |
ingH2O | Pengukur banyu inci |
mmHg | mm merkuri |
Torr | Torr |
liter/jam | Liter saben jam |
liter / min | Liter saben menit |
%RH | % Kelembapan Relatif |
%O2 | %oksigen |
%CO2 | % Karbon dioksida |
%CP | % Potensi Karbon |
V | Volt |
A | Amps |
mA | Milli Amps |
mV | Mili Volt |
ohm | Ohm |
ppm | Bagean saben yuta |
rpm | Revolusi saben menit |
mSec | Mili detik |
Sek | Detik |
min | menit |
jam | jam |
PH | PH |
%PH | %PH |
mil/jam | Mil saben jam |
mg | Mili gram |
g | Gram |
kg | Kilo gram |
TABEL - 2 | ||
Pilihan | Range (Min. nganti Maks.) | Resolusi |
![]() |
0 nganti +960°C / +32 nganti +1760°F |
Tetep 1°C / 1°F |
![]() |
||
![]() |
||
|
0 nganti +1771°C / +32.0 nganti +3219°F |
|
![]() |
0 nganti +1768°C / +32 nganti +3214°F |
|
![]() |
||
![]() |
||
![]() |
Reserved kanggo jinis Thermocouple khusus pelanggan sing ora kadhaptar ing ndhuwur. | |
![]() |
-199 nganti +600°C / -328 nganti +1112°F
–199.9 kanggo or iki 1112.0 ° F 600.0°C / -328.0 |
Pangguna sing bisa disetel 1°C / 1°F
utawa 0.1°C / 0.1°F |
|
19999 kanggo +30000 unit | Pangguna settable 1 / 0.1 / 0.01/
0.001 ing |
ID SETTING kanggo luwih saka 1 CIM
Ditrapake mung kanggo UNILOG PRO PLUS
LAPORAN PANEL FRONT
Simbol |
Kunci | Fungsi |
![]() |
PAGE | Pencet kanggo mlebu utawa metu saka mode persiyapan. |
![]() |
TURUN |
Pencet kanggo nyuda nilai parameter. Pencet sapisan nyuda nilai kanthi siji count; terus dipencet nyepetake owah-owahan. |
![]() |
UP |
Pencet kanggo nambah nilai parameter. Pencet sapisan nambah nilai kanthi siji count; terus dipencet nyepetake owah-owahan. |
![]() |
ENTER | Pencet kanggo nyimpen nilai parameter sing disetel lan kanggo nggulung menyang parameter sabanjure ing PAGE. |
SAMBUNGAN LISTRIK
MODUL ANTARMUKA PENGGUNA (UIM)
PORT KOMUNIKASI KAnggo INTERFACING KARO CIM(S)
Ditrapake mung kanggo UNILOG PLUS
SETTING JUMPER
MODUL ANTARA WAJAH SALURAN INPUT (CIM)
SETTING JUMPER
MODUL ANTARA WAJAH SALURAN INPUT (CIM)
SAMBUNGAN LISTRIK
MODUL ANTARMUKA SALURAN (CIM)
Dokumen / Sumber Daya
![]() |
PPI UniLog Pro Temperatur Data Logger [pdf] Instruksi Manual UniLog Pro Temperatur Data Logger, UniLog Pro, Temperatur Data Logger, Data Logger, Logger |