Masibus Analog Output Field Interface Board hà 8 canali chì accetta diversi tipi di currente / voltage segnali è li converte in corrente / voltage signali. Hè un rail DIN universale compactu muntatu cù cunnessione di input è output marcate. L'ajustamentu indipendente di zero & span per ogni canale hè pussibule.

APPLICAZIONE

  • Eliminate Ground Loop problems
  • Protect Expensive control systems against Field Faults
  • Isolate and Translate System Signals
  • Field Interface for PLC/DCS/SCADA systems

SPECIFICATION

Input

  • No. of Channels & Type 8 Channel DC Volt/Current (Factory Set)
  • Gamma di input
    • Per Voltage: 1-5VDC,0-5VDC,0-10VDC
    • For Current: 4-20ma, 0-20ma
  • Input Impedance Current I/P: 100 Ohms, Voltage I/P :> 5M
    I/P connection MKDS or 25pin D Type connector
  • Output
    • Tipu di output
    • Voltage/ Current
  • Gamma di output
    • Per Voltage: 1-5VDC,0-5VDC,0-10VDC
    • For Current: 4-20mA, 0-20ma
  • Output Resistenza di carica
    • 0/1 to 5V@ 1KΩ min,
    • 0 to 10V@ 3KΩ min
    • 0/4mA to 20mA@750Ω max
  • Fault LED Indication
  • Red LED for over/under range (1-5V/4-20mA only)
  • Response Time ≤20milisecond
  • Accuracy 0.1% of output span
  • Drift 0.1% per Year
  • Calibration Zero & Span Individual per channel by multi-turn trim pots O/P connection MKDS connector

Alimentazione elettrica

  • Power Supply 24VDC ±10%
  • Power Consumption < 12VA
  • Classificazione di fusible 2Amp (Soffiu Rapidu)
  • LED Indication Green LED – Healthy Status, Red LED –Fault Status
  • Isolation 1.5KV AC Input to Power, Output to Output and Input to Output , Output to Power

Ambientale

  • Operating temperature Operating at 0 to 50C
  • Temp. Co-efficient ≤ 100 PPM
  • Relative humidity 30 to 95% RH non- condense
  • Environmental Protection Conformal Coating on PCB

Fisica

  • Mounting Type DIN Rail (35 mm width)
  • Dimensions 225(L) x 90(W) x 90(D)
  • Weight Approx 400 gm

Dettaglio di Terminal

  • Terminal Block UL, CSA standard
  • Terminal Cable Size up to 2.5mm² conductor

masibus-MAS-AO-08-D-Analog -Output-Field -Interface-Board-fig (1)

  • 8 channel configurations
  • Wide range of DC inputs and outputs
  • Independent zero & span for each channel
  • Facile à calibre
  • Accepts non-std. signal input option
  • Montatu su rail DIN
  • Dimensione Compact

Dimensione

225 (L) x 90 (L) x 90 (P)

masibus-MAS-AO-08-D-Analog -Output-Field -Interface-Board-fig (2)

SIGURTÀ È AVVERTENZA

As MAS-AO-08-D with front panel potentiometer calibration, must not be exposed to heavy shocks or vibration which may cause SCM to get out of calibration. To avoid Electrostatic Discharge (ESD) to the SCM, which may cause permanent damage, always ground yourself by touching some ground equipment. Before installation or beginning of any troubleshooting procedures the power to all equipment must be switched off and isolated. Units suspected of being faulty must be disconnected and removed first and brought to a properly equipped workshop for testing and repair. Component replacement and internal adjustments must be made by a company person only. Wiring must be carried out by personnel, who have basic electrical knowledge and practical experience. All wiring must confirm to appropriate standards of good practice and local codes and regulations. Wiring must be suitable for voltage, currente, è a temperatura di u sistema. Attenti à ùn stringhje micca eccessivamente i viti terminali.

CONNESSIONE

Elementi di cuntrollumasibus-MAS-AO-08-D-Analog -Output-Field -Interface-Board-fig (3)

Item nos. Dettagli
1 Main Power supply with electronic grounding
2 Fuse Fail LED indication
3 Power ON LED indication
4 MKDS Interface connector to DCS
5 25 Pin D type Male interface connector to DCS
6 Field output terminals
7 Product serial no.

Dettagli di cunnessionemasibus-MAS-AO-08-D-Analog -Output-Field -Interface-Board-fig (4)

Connect rated power at terminal where 24vdc+ & 24VDC- is described in the wiring diagram. Field Input/output Terminals: Connect input between terminal where Input+ & Input- for particular channel for Input Or 25 pin D type PCB mounted male connector & take output from where Output+ & Output- described in connection details.

Dettagli di cunnessione di input per 25 Pin D Type

Pin No. Descrizzione
1 Input0+
2 Input0-
3 Input1+
4 Input1-
5 Input2+
6 Input2-
7 Input3+
8 Input3-
9 Input4+
10 Input4-
11 Input5+
12 Input5-
13 Input6+
14 Input6-
15 Input7+
16 Input7-

DIAGRAMMA DI BLOCCHImasibus-MAS-AO-08-D-Analog -Output-Field -Interface-Board-fig (5)

INSTALLAZIONEmasibus-MAS-AO-08-D-Analog -Output-Field -Interface-Board-fig (6)

Muntamentu:

Place the module with the DIN rail guide way on the bottom edge of the DIN rail and then snap it downwards. The housing is mounted on the DIN rail by swiveling it into place. The Horizontal mounting arrangement Shown here, allows good vertical air circulation .It is also recommended to keep the adequate gap between two SCM.

Eliminazione:

Rilasciate u snap-on catch cù un cacciavite è poi staccate u modulu da u bordu di fondu di a Rail DIN.

CODICE D'ORDINE

CODICE D'ORDINE
 

Mudellu

Tipu di input & Range Tipu di Output & Range  

Cunnessione di input

MAS-AO- 08-D x   x   x  
  C 4-20 mA C 4-20 mA 0 PCB Terminal Block
D 0-20 mA D 0-20 mA 1 D Type connector
E 1-5 VDC E 1-5 VDC  
F 0-5 VDC F 0-5 VDC
G 0-10 VDC G 0-10 VDC
S Speciale S Speciale
CODICE D'ORDINE DI CABLE
Mudellu Tipu di input & Range
m-PC-D25F-LG XX  
  C 2.5 Metru
D 3.0 Metru
E 3.5 Metru
F 5.0 Metru
G 7.0 Metru
S Speciale

SOLUZIONE DI PROBLEMI

L'unità ùn si accende micca?

If RED LED on the module is ON, then the problem can be bad connection or due to incorrect rating of power fuse blows. If GREEN LED on the module is ON, it indicates the module is in healthy condition.

Unstable/Vague Reading

Verificate per e cunnessione sciolte.

First verify that all conventional instrumentation norms have been followed for wiring. Make noise away from the module. Check for ripple on power supplies of Input & Output section. Output not matching with the expected value Kindly make sure that the output is really incorrect with respect to input signal before attempting any re-calibration.

Fluctuation in Reading

The reason can be reverse input connections.

Masibus Automation & Instrumentation Pvt. Ltd.

FAQ

  • Q: Quanti canali hà u MAS-AO-08-D?
    • A: U MAS-AO-08-D hà 8 canali.
  • Q: Chì ghjè a gamma di temperatura operativa di u pruduttu?
    • A: The product operates at temperatures ranging from 0 to 50°C.
  • Q: Cumu possu calibre l'output per ogni canale?
    • A: Calibration for zero & span for each channel can be adjusted individually using multi-turn trim pots.