masibus MAS-AO-08-D Analog Output Field Interface Board
Masibus Analog Output Field Interface Board has 8 channels that accepts various types of current/voltage signals and converts them to isolated current/voltage signals. It is compact universal DIN rail mounted with labeled input and output connections. Independent zero & span adjustment for each channel is possible.
አፕሊኬሽን
- Eliminate Ground Loop problems
- Protect Expensive control systems against Field Faults
- Isolate and Translate System Signals
- Field Interface for PLC/DCS/SCADA systems
SPECIFICATION
ግቤት
- No. of Channels & Type 8 Channel DC Volt/Current (Factory Set)
- የግቤት ክልል
- ለ Voltage: 1-5VDC,0-5VDC,0-10VDC
- For Current: 4-20ma, 0-20ma
- Input Impedance Current I/P: 100 Ohms, Voltage I/P :> 5M
I/P connection MKDS or 25pin D Type connector - ውፅዓት
- የውጤት አይነት
- ጥራዝtagሠ/ የአሁን
- የውጤት ክልል
- ለ Voltage: 1-5VDC,0-5VDC,0-10VDC
- For Current: 4-20mA, 0-20ma
- Output Load resistance
- 0/1 to 5V@ 1KΩ min,
- 0 to 10V@ 3KΩ min
- 0/4mA to 20mA@750Ω max
- Fault LED Indication
- Red LED for over/under range (1-5V/4-20mA only)
- Response Time ≤20milisecond
- Accuracy 0.1% of output span
- Drift 0.1% per Year
- Calibration Zero & Span Individual per channel by multi-turn trim pots O/P connection MKDS connector
የኃይል አቅርቦት
- Power Supply 24VDC ±10%
- Power Consumption < 12VA
- ፊውዝ ደረጃ አሰጣጥ 2Amp (ፈጣን የተነፋ)
- LED Indication Green LED – Healthy Status, Red LED –Fault Status
- Isolation 1.5KV AC Input to Power, Output to Output and Input to Output , Output to Power
አካባቢ
- Operating temperature Operating at 0 to 50C
- Temp. Co-efficient ≤ 100 PPM
- Relative humidity 30 to 95% RH non- condense
- Environmental Protection Conformal Coating on PCB
አካላዊ
- Mounting Type DIN Rail (35 mm width)
- Dimensions 225(L) x 90(W) x 90(D)
- Weight Approx 400 gm
የተርሚናል ዝርዝር
- Terminal Block UL, CSA standard
- Terminal Cable Size up to 2.5mm² conductor
- 8 channel configurations
- Wide range of DC inputs and outputs
- Independent zero & span for each channel
- ለመለካት ቀላል
- Accepts non-std. signal input option
- DIN ባቡር ተጭኗል
- የታመቀ መጠን
ልኬት
225 (L) x 90 (ወ) x 90 (መ)
ደህንነት እና ማስጠንቀቂያ
As MAS-AO-08-D with front panel potentiometer calibration, must not be exposed to heavy shocks or vibration which may cause SCM to get out of calibration. To avoid Electrostatic Discharge (ESD) to the SCM, which may cause permanent damage, always ground yourself by touching some ground equipment. Before installation or beginning of any troubleshooting procedures the power to all equipment must be switched off and isolated. Units suspected of being faulty must be disconnected and removed first and brought to a properly equipped workshop for testing and repair. Component replacement and internal adjustments must be made by a company person only. Wiring must be carried out by personnel, who have basic electrical knowledge and practical experience. All wiring must confirm to appropriate standards of good practice and local codes and regulations. Wiring must be suitable for voltagሠ፣ የአሁኑ እና የስርዓቱ የሙቀት መጠን ደረጃ። የተርሚናል ብሎኖች ከመጠን በላይ እንዳይጨምሩ ይጠንቀቁ።
ግንኙነት
የመቆጣጠሪያ አካላት
Item nos. | ዝርዝሮች |
1 | Main Power supply with electronic grounding |
2 | Fuse Fail LED indication |
3 | Power ON LED indication |
4 | MKDS Interface connector to DCS |
5 | 25 Pin D type Male interface connector to DCS |
6 | Field output terminals |
7 | Product serial no. |
የግንኙነት ዝርዝሮች
Connect rated power at terminal where 24vdc+ & 24VDC- is described in the wiring diagram. Field Input/output Terminals: Connect input between terminal where Input+ & Input- for particular channel for Input Or 25 pin D type PCB mounted male connector & take output from where Output+ & Output- described in connection details.
Input Connection Details for 25 Pin D Type
ፒን ቁጥር | መግለጫ |
1 | Input0+ |
2 | Input0- |
3 | Input1+ |
4 | Input1- |
5 | Input2+ |
6 | Input2- |
7 | Input3+ |
8 | Input3- |
9 | Input4+ |
10 | Input4- |
11 | Input5+ |
12 | Input5- |
13 | Input6+ |
14 | Input6- |
15 | Input7+ |
16 | Input7- |
የማገጃ ንድፍ
መጫን
መጫን፡
Place the module with the DIN rail guide way on the bottom edge of the DIN rail and then snap it downwards. The housing is mounted on the DIN rail by swiveling it into place. The Horizontal mounting arrangement Shown here, allows good vertical air circulation .It is also recommended to keep the adequate gap between two SCM.
ማስወገድ፡
ስክራፕድራይቨርን ተጠቅመው የጨረሰውን መያዣ ይልቀቁት እና ሞጁሉን ከDIN Rail ግርጌ ጫፍ ያላቅቁት።
የትእዛዝ ኮድ
የትእዛዝ ኮድ | ||||||
ሞዴል |
የግቤት አይነት እና ክልል | የውጤት አይነት እና ክልል |
የግቤት ግንኙነት |
|||
MAS-AO- 08-ዲ | x | x | x | |||
C | 4-20mA | C | 4-20mA | 0 | PCB Terminal Block | |
D | 0-20mA | D | 0-20mA | 1 | D Type connector | |
E | 1-5VDC | E | 1-5VDC | |||
F | 0-5VDC | F | 0-5VDC | |||
G | 0-10VDC | G | 0-10VDC | |||
S | ልዩ | S | ልዩ |
የኬብል ማዘዣ ኮድ | ||
ሞዴል | የግቤት አይነት እና ክልል | |
m-PC-D25F-LG | XX | |
C | 2.5 ሜትር | |
D | 3.0 ሜትር | |
E | 3.5 ሜትር | |
F | 5.0 ሜትር | |
G | 7.0 ሜትር | |
S | ልዩ |
መተኮስ ችግር
Unit Not Turning ON?
If RED LED on the module is ON, then the problem can be bad connection or due to incorrect rating of power fuse blows. If GREEN LED on the module is ON, it indicates the module is in healthy condition.
Unstable/Vague Reading
የተበላሹ ግንኙነቶችን ያረጋግጡ።
First verify that all conventional instrumentation norms have been followed for wiring. Make noise away from the module. Check for ripple on power supplies of Input & Output section. Output not matching with the expected value Kindly make sure that the output is really incorrect with respect to input signal before attempting any re-calibration.
Fluctuation in Reading
The reason can be reverse input connections.
Masibus Automation & Instrumentation Pvt. Ltd.
- B/30, GIDC Electronics Estate, Sector- 25,
- Gandhinagar-382044, Gujarat, India
- ፒኤች: +91 79 23287275-77
- ኢሜይል፡- support@masibus.com
- Web: www.masibus.com
የሚጠየቁ ጥያቄዎች
- Q: How many channels does the MAS-AO-08-D have?
- A: The MAS-AO-08-D has 8 channels.
- ጥ: የምርቱ የአሠራር የሙቀት መጠን ምን ያህል ነው?
- A: The product operates at temperatures ranging from 0 to 50°C.
- Q: How can I calibrate the output for each channel?
- A: Calibration for zero & span for each channel can be adjusted individually using multi-turn trim pots.
ሰነዶች / መርጃዎች
![]() |
masibus MAS-AO-08-D Analog Output Field Interface Board [pdf] የተጠቃሚ መመሪያ MAS-AO-08-D Analog Output Field Interface Board, MAS-AO-08-D, Analog Output Field Interface Board, Output Field Interface Board, Field Interface Board, Interface Board |