  • Heat source connection & control setup – Professional installation guide Before proceeding to phase 4, ensure that phase 3 has been fully completed.

Phase 4 Professional - Koneksyon sa tinubdan sa init ug pag-setup sa pagkontrol

  • Siguruha nga ang usa ka kwalipikado nga propesyonal naghimo sa mga mosunud nga lakang. Palihug pag-amping nga ang tanan nga gikinahanglan nga mga lakang sa miaging mga hugna nahuman na.

PAG-INSTALL

LAKANG 1

  • Pre-Connection checklist
  • Sa dili pa ikonektar ang manifold ngadto sa tinubdan sa kainit, paghimo og pressure test sa floor heating system, mga tubo, ug manifold. Pagtul-id sa bisan unsang tinubdan sa pagkawala sa presyur.WUNDA-Phase-4-Heat-Source-Connection-and-Control-Setup-FIG- (2)

LAKANG 2

  • Pagkonektar sa manifold ngadto sa tinubdan sa kainit
  • Each manifold(s) must have independent feed(s) from the heat source.
  • It is recommended for an s-plan/s-plan + to be configured so each system sharing the heat source has its own 2 port motorised valve. Allowing separation of the systems and each to have its own call to the heat source.

To connect to isolation valves on either side of the mixing valve, use a 1” male iron to 15mm, 22mm, or 28mm compression fitting.

  • 2–4 port manifolds: 15mm feeds
  • 4–8 port: 22mm feeds
  • 8–12 port: 28mm feeds

Siguruha nga ang balbula sa pagsagol sa manifold hingpit nga sirado sa dili pa ipasulod ang gipainit nga tubig.

WUNDA-Phase-4-Heat-Source-Connection-and-Control-Setup-FIG- (3)

LAKANG 3

  • Pagpagawas sa hangin gikan sa sistema
  • Kung ang manifold konektado sa gigikanan sa kainit, ug ang mga feed napuno pagsiguro nga ang mga loop sa pagpainit sa salog magpabilin nga nahimulag. Susiha nga ang mga flow meter ug ang mga balik nga balbula sirado (gituyok sa hingpit nga sunud-sunod).

WUNDA-Phase-4-Heat-Source-Connection-and-Control-Setup-FIG- (4)

Kini magsiguro nga ang bisan unsang hangin nga gipasulod gikan sa mga feed ngadto sa manifold mahimong ma-vented gamit ang manual air vents nga dili motugot sa bisan unsang hangin ngadto sa UFH loops.

WUNDA-Phase-4-Heat-Source-Connection-and-Control-Setup-FIG- (5)

LAKANG 4

  • Pagdugang inhibitor sa sistema
  • Dosis ang sistema sa usa ka angay nga tigpugong sama sa bisan unsang sentral nga sistema sa pagpainit. Ipaila ang tigpugong sa bisan unsang angay nga pagpuno nga punto. Aron makalkulo ang gidaghanon sa tubig:
  • 16mm pipe: Total loop length × 0.113 = litres
  • 12mm pipe: Total loop length × 0.061 = litres
  • Use loop lengths from the pipe layout drawing.

WUNDA-Phase-4-Heat-Source-Connection-and-Control-Setup-FIG- (6)

For the HubSwitch guide please see:
https://www.wundagroup.com/wp-content/uploads/2025/03/HubSwitch-manual_v2.pdf

LAKANG 5
Wiring and control

  • Ang mosunod nga mga instruksyon kay para sa Wunda smart controls. Kung naggamit ka ug standard nga mga kontrol gikan sa Wunda, palihug sunda ang may kalabutan nga fact sheet. Kung naggamit ka sa mga kontrol sa ikatulo nga partido, palihug siguruha nga sundon ang ilang giya.

Single-zone manifolds using Wunda smart controls

  • For single-zone manifolds (all loops run together), electronic actuators and a connection box are not needed.
  • Open all manual return valves by hand (anticlockwise).

WUNDA-Phase-4-Heat-Source-Connection-and-Control-Setup-FIG- (7)

Use a HubSwitch channel (230V) to trigger:

  • Brown wire of manifold zone valve Live wire of the manifold pump
  • Paghimo angay nga mga koneksyon alang sa mga bomba nga neyutral ug yuta. Ang nahabilin nga mga kable sa balbula sa zone mobalik sa s-plan nga kahon sa mga kable sunod sa gigikanan sa kainit, gray ug orange nga gigamit aron ma-trigger ang gigikanan sa kainit.
  • Ang HubSwitch kinahanglan nga ma-configure sa angay nga channel mode gamit ang dip switch ug jumper connection. Palihug sunda ang mga instruksyon sa HubSwitch alang sa tukma nga pag-configure depende sa imong gigamit niini aron ma-trigger.

Pag-wire ug pagkontrol sa multi-zone manifold gamit ang Wunda smart controls

  • Wiring sa kahon sa koneksyon alang sa multizone manifolds. Ang mga electronic actuator gigamit aron tugotan ang (mga) loop nga modagayday nga independente sa usag usa kung ang lain-laing mga sona nagtawag alang sa kainit. Gi-wire kini sa kahon sa koneksyon ug gi-configure sa app. Kung magbutang ug labaw sa usa ka multizone manifold usa ka kahon sa koneksyon ang gikinahanglan alang sa matag usa, max sa 4 ka kahon sa koneksyon matag hub.
  • Pag-mount Note: Ayaw i-mount ang kahon sa koneksyon sa ilawom sa manifold aron malikayan ang kadaot sa tubig.

WUNDA-Phase-4-Heat-Source-Connection-and-Control-Setup-FIG- (8)

Kuhaa ang tanan nga manual return valve caps ug ipahiangay ang mga electronic actuator sa ilang lugar. Itago ang manwal nga mga takup alang sa umaabot nga paggamit tungod kay kini mapuslanon kung pun-on pag-usab o paglimpyo sa mga galong sa hangin.
Mga Instruksyon sa Wiring:

  • Ikonektar ang live ug neutral nga mga wire sa actuator sa angay nga mga terminal sa actuator L&N sa kahon sa koneksyon. Sa han-ay, 1-12 (depende sa gidak-on sa manifold).
  • Ang mga zone ma-configure sa ulahi sa app kung gi-configure ang mga kwarto kung diin (mga) actuator ang ma-trigger kung ang matag kwarto nanawagan alang sa kainit.
  • Ikonektar ang manifold pump nga buhi, neyutral ug yuta sa gimarkahan nga mga terminal sa kahon sa koneksyon.

WUNDA-Phase-4-Heat-Source-Connection-and-Control-Setup-FIG- (9)

  • The brown of the zone valve for the floor heating manifold should go into the normally open (NO) terminal on the connection box with a link made between the AC out 230V L to COM.
  • Optional: Use a 230V HubSwitch channel to trigger the manifold zone valve.
  • If triggering the heat source directly (not part of an s-plan) the relay can be used, either volt free with no link or 230V with a link made to COM.
  • The HubSwitch can also be used, refer to its instruction to configure for one channel 230V or volt free mode.

LAKANG 6

Pagpares sa sistema ug pag-configure pinaagi sa app

  • Testing before pairing:
  • Kahon sa koneksyon:
  • To test outputs on the connection box, hold the test button for 5 seconds to enter test mode (Test LED will flash blue)
  • Tap the test button to cycle outputs to the right, through each actuator an LED will illuminate to show which output is being tested.
  • Tap the test button to cycle to the left to test the relay and manifold pump.
  • When you have confirmed the wiring is correct exit test mode by holding the test button.

VWUNDA-Phase-4-Heat-Source-Connection-and-Control-Setup-FIG- (10)

HubSwitch:

  • To test outputs on the HubSwitch hold boost 1 & 2 buttons together for 5 seconds,
  • Tapping boost 1 will allow you to cycle through each channel the LED flashes to show which channel is being tested (depending on how the Hub is configured).
  • Tapping boost 2 will toggle that channel on/off showing a green LED when on, or a red LED when off.
  • Hold both boost 1 & 2 to come out of test mode.

WUNDA-Phase-4-Heat-Source-Connection-and-Control-Setup-FIG- (11)

Proseso sa pag-setup sa app:

  • Palihug siguroha nga ang imong router nagsibya og 2.4GHz WiFi. Ang pipila ka mga lakang mahimong kinahanglan buhaton aron masiguro kini sa router o sa broadband provider. Kinahanglan kini alang sa bisan unsang mga smart control.
  • Download WundaHome app, create an account, and select:
  • Add System > Add HubSwitch
  • Sunda ang mga instruksyon sa app aron ma-setup ang HubSwitch nga magkonektar niini sa internet ug ipares kini sa imong account (mahimo kining ibalhin gamit ang transfer code human sa pag-commissioning).
  • Ipares ang (mga) kahon sa koneksyon sa sistema pinaagi sa pagsunod sa mga instruksyon sa app nga naghatag sa matag usa sa angay nga ngalan kung daghang mga kahon sa koneksyon ang nagngalan kanila base sa lainlain nga gikontrol niini.
  • Paghimo ug ngalan sa mga lawak sa app.
  • Ipares ang usa ka thermostat sa matag kwarto, pagsunod sa mga panudlo sa app.
  • Lakaw ngadto sa Room Settings > Advanced Parameters > Connection Box Configuration:
  • I-highlight ang mga actuator alang niana nga kwarto. Ug ang "Relay" kung ang relay sa kahon sa koneksyon gigamit aron ma-trigger ang balbula sa zone / gigikanan sa init.
  • Kung dili gamiton ang relay sa kahon sa koneksyon aron ma-trigger ang balbula sa zone / gigikanan sa kainit pilia ang angay nga channel sa "HubSwitch channel configuration".
  • Balika kini aron ma-configure ang angay nga mga output alang sa matag kwarto.

LAKANG 7

  • Inisyal nga pagsugod sa sistema ug pag-setup sa rate sa dagan
  • Manually set the flow rates for each loop. Set the mixing valve to minimum to start, open it up to achieve a higher flow temperature, indicated on the top temperature gauge.
  • Ablihi ang mga flow meter (ug mga manual return valve caps kung usa ka zone manifold).
  • Pagtawag alang sa kainit sa tanan nga mga lawak sa pagpainit sa salog sa app pinaagi sa pagpili sa mas taas nga temperatura kay sa kasamtangan nga temperatura sa lawak.
  • Sulod sa 2-5 ka minuto ang mga actuator kinahanglan nga mag-trigger, ang manifold pump ug ang gatilyo ngadto sa tinubdan sa kainit.
  • Kinahanglang i-adjust ang flow rates sa flow meter.
  • Ibutang ang mga rate sa pag-agos nga nagsunod sa lamesa sa drowing sa layout sa tubo. Mahimong manginahanglan kini og gamay nga mga pagbag-o, kung ang mga rate sa pag-agos gitakda sa husto kinahanglan nimo nga makakuha usa ka 7 ° nga kalainan tali sa dagan ug pagbalik nga mga gauge sa temperatura. (5-10° madawat).

WUNDA-Phase-4-Heat-Source-Connection-and-Control-Setup-FIG- (12)

  • Ang mas paspas nga rate sa dagan sa usa ka loop mas ubos ang differential, mas hinay nga rate sa dagan moresulta sa mas taas nga differential.
  • Kung nanlimbasug aron makab-ot ang husto nga rate sa pag-agos, susiha nga ang bomba naa sa husto nga mode alang sa pagpainit sa ilawom sa salog. Mahimo usab nga adunay hangin sa mga galong, balika ang pamaagi sa pagpuno aron masiguro nga wala’y hangin nga hinungdan sa pagsukol sa loop nga nagpahinay sa rate sa pag-agos.
  • Kini nga mga instruksyon kay higpit nga gamiton sa mga sistema sa Wunda lamang — ang paggamit niini sa bisan unsang laing sistema mahimong moresulta sa seryoso nga mga isyu sa performance, pagkapakyas sa sistema, o pagka-invalidate sa imong warranty.

garantiya

  • Kini nga mga instruksyon kay higpit nga gamiton sa mga sistema sa Wunda lamang — ang paggamit niini sa bisan unsang laing sistema mahimong moresulta sa seryoso nga mga isyu sa performance, pagkapakyas sa sistema, o pagka-invalidate sa imong warranty.
  • www.wundagroup.com 01291 634 149

Kanunay nga Gipangutana nga mga Pangutana

P: Mahimo ba nako gamiton kini nga mga panudlo sa mga sistema gawas sa Wunda?

A: No, these instructions are strictly for use with Wunda systems only. Using them with any other system may result in serious performance issues, system failure, or invalidation of your warranty.