  • Resolver Option MCB 103 for FC 360
  • Used for interfacing the resolver motor feedback to the FC 360 frequency converters
  • Resolver poles: 17-50 Poles – 2 * 2
  • Vrms: *10.0 kHz
  • Transformation ratio: Pangalawang input voltage Max. 4 Vrms
  • Secondary load: App. 10 k

Mga Tagubilin sa Paggamit ng Produkto

Mga Tagubilin sa Kaligtasan
BABALA: ORAS NG PAGDABAS

  1. Itigil ang motor.
  2. Idiskonekta ang mga AC mains, permanenteng magnet type na motor, at malayuang DC-link na mga power supply, kabilang ang mga back-up ng baterya, UPS, at mga koneksyon sa DC-link sa iba pang mga frequency converter.
  3. Wait for the capacitors to discharge fully before performing any service or repair work. The waiting time is specified in Table 1.2.

Mga Ibinigay na Item
For J1-J5 enclosure types, a terminal cover must be ordered separately. For J6 and J7 enclosure types, no separate terminal covers are needed.

Pag-mount ng Opsyon
Mount the option according to the provided illustrations.

Pag-install ng Elektrisidad
PAUNAWA: Always use screened motor cables and brake chopper cables. Separate resolver cables from motor cables. Connect the screen of the resolver cable to the de-coupling plate on the frequency converter side, and connect to the chassis (earth) on the motor side.

Ambient Working Temperature
Refer to Table 1.4 for the ambient working temperature at full load.

Resolver Option MCB 103 for FC 360 is used for interfacing the resolver motor feedback to FC 360 frequency converters.

Mga pole ng solver 17-50 Poles: 2 *2
Resolver input voltage 17-51 Input Voltage: 2.0–8.0 Vrms *7.0

Vrms

Resolver input frequency 17-52 Input Frequency: 2–15 kHz

*10.0 kHz

ratio ng pagbabago 17-53 Transformation Ratio: 0.1–1.1 *0.5
Pangalawang input voltage Max. 4 Vrms
Secondary load App. 10 kΩ

Mga Tagubilin sa Kaligtasan

BABALA ORAS NG PAGDABAS
The frequency converter contains DC-link capacitors, which can remain charged even when the frequency converter is not powered. Failure to wait the specified time after power has been removed before performing service or repair work could result in death or serious injury.

  1. Itigil ang motor.
  2. Idiskonekta ang mga AC mains, permanenteng magnet type na motor, at malayuang DC-link na mga power supply, kabilang ang mga back-up ng baterya, UPS, at mga koneksyon sa DC-link sa iba pang mga frequency converter.
  3. Wait for the capacitors to discharge fully before performing any service or repair work. The duration of waiting time is specified in Table 1.2.
     

    Voltage [V]

    Minimum na oras ng paghihintay (minuto)
    4 15
    380-480 0.37-7.5 kW 11-75 kW
    Mataas na voltage maaaring naroroon kahit na ang mga LED na babala ay naka-off!

Mga Ibinigay na Item

Resolver Option MCB 103
PAUNAWA
For J1-J5 enclosure types, a terminal cover must be ordered separately. For J6 and J7 enclosure types, no separate terminal covers are needed.

Enclosure Numero ng pag-order
J1 132B0263
J2 132B0265
J3 132B0266
J4 132B0267
J5 132B0268

Pag-mount ng Opsyon

Mount the option according to Illustration 1.1 and Illustration 1.2.

Danfoss-MCB-103-Resolver-Option-Automation-Drive-fig-2
Danfoss-MCB-103-Resolver-Option-Automation-Drive-fig-3

Ambient Working Temperature

For ambient working temperature af full load, see Table 1.4.

  Without MCB With MCB
Standard Control Card 45-50 °C* 45 °C
Profibus or ProfiNet 45 °C 40 °C

Some types can reach 50 °C, see VLT® AutomationDrive FC 360 Design Guide.

Pag-install ng Elektrisidad

PAUNAWA

  • Always use screened motor cables and brake chopper cables.
  • Separate resolver cables from motor cables.
  • Connect the screen of the resolver cable to the de-coupling plate on the frequency converter side, and connect to the chassis (earth) on the motor side.

    Danfoss-MCB-103-Resolver-Option-Automation-Drive-fig-4

TUNGKOL SA KOMPANYA

FAQ

What should I do if the warning LEDs are off but high voltage baka nandoon pa?
Mataas na voltage may still be present even when the warning LEDs are off. Follow safety protocols and refer to the provided instructions for proper discharge time before servicing or repair work.

Mga Dokumento / Mga Mapagkukunan

Danfoss MCB 103 Resolver Option Automation Drive [pdf] Gabay sa Pag-install
MCB 103, MCB 103 Resolver Option Automation Drive, MCB 103, Resolver Option Automation Drive, Option Automation Drive, Automation Drive

Mga sanggunian

Mag-iwan ng komento

Ang iyong email address ay hindi maipa-publish. Ang mga kinakailangang field ay minarkahan *