RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

Product Overview

The H17 series offers field-adjustable power and color temperature settings. This guide covers installation for various mounting options and accessories.

H17 / H17S, H17XL, H17XXL

Important Safety Information

Read carefully before installing. Retain these instructions for future reference. All RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. Installation must be performed by a qualified person familiar with the product and hazards involved. Ensure power is OFF before installing or maintaining. No user serviceable parts inside. Suitable for wet locations. Maximum ambient temperature: 50°C (122°F).

Hook Mounting

  1. Screw the Hook into the Fixture, tighten and secure with Set Screw (Fig. 1).
  2. Hang the Fixture on a ceiling hook or chain (by others). Ensure the Tether Cable (for H17XXL and H17XXL/480) is secured on the Fixture. Secure the other end of the Tether Cable to the mounting structure as shown in Fig. 2.
  3. After installation, connect the fixture wires to power supply using appropriate UL approved wire connectors as required by code (Fig. 30).
Fig. 1: Hook Mounting Detail
Fig. 2: Tether Cable Connection

Surface Mounting

Accessory ordered separately - Model # H17-SM Kit, H17XXL-SM KIT.

  1. Align the Surface Mount Kit screw holes with the Heat Sink as shown in Fig. 3 and install the Surface Mount Kit onto the Heat Sink with (4) Screws (provided) as shown in Fig. 4.
  2. Secure the Surface Mount Kit to the mounting surface (Fig. 5).
  3. After installation, connect the fixture wires to power supply using appropriate UL approved wire connectors as required by code.
  4. Loosen Pivot Bolts and swivel the fixture to the desired angle. Fixture can adjust 50° to the left or right vertically (Fig. 6), tighten Pivot Bolts.
Fig. 3: Surface Mount Kit Alignment
Fig. 4: Surface Mount Kit Attachment
Fig. 5: Surface Mount Kit Installation
Fig. 6: Field-Adjustable Angle Adjustment

Pendant Mounting

Accessory ordered separately - Model # H17-PM KIT, H17B-PM KIT, H17XXL-PM KIT, H17XXLB-PM KIT.

  1. Loosen Set Screws on the Fixture as shown in Fig. 7. Mount the Pendant Kit onto the driver housing using (1) Bolt (provided) to secure the Pendant Kit to driver housing, tighten Set Screw.
  2. Insert 3/4" NTP Pendant Stem (by others) into the Pendant Kit and secure with Set Screw (Fig. 8 & 9).
  3. After installation, connect the fixture wires to power supply using appropriate UL approved wire connectors as required by code (Fig. 30).
Fig. 7: Pendant Kit Attachment
Fig. 8: Pendant Stem Installation
Fig. 9: Pendant Stem Securing

Field-Adjustment

Follow instructions below to change fixture Power (W) and/or Color Temperature (CCT) from the factory settings.

Factory Settings:

  1. Locate the Field-Adjustable Switches on Fixture housing as shown below. Remove Plug.
  2. Select Power (W) and/or Color Temperature (CCT) by sliding the respective switch to the desired setting (Fig. 10). Re-install the Plug.
Fig. 10: Field-Adjustable Switches

Polycarbonate Refractor Mounting

(Accessory Kit, Do Not Use With H17XXL)

Accessory ordered separately - Model # H17-RPC and H17XL-RPC.

  1. Align the Refractor Screw Holes with the Heat Sink as shown in Fig. 12 and 13.
  2. Install Refractor onto the Heat Sink as shown in Fig. 14. Secure the Refractor to the Heat Sink with (4) Screws (provided), as shown in Fig. 15.
Fig. 12 & 13: Refractor Alignment
Fig. 14 & 15: Refractor Installation

Drop Lens Mounting

(Accessory Kit, Do Not Use With H17XXL)

Accessory ordered separately - Model # H17-RDL, H17XL-RDL.

  1. Place the Drop Lens on the Reflector as shown in Fig.16 & 17.
  2. Clamp the Steel Ring onto the Drop Lens and secure with Spring as shown in Fig.18 & 19.
Fig. 16 & 17: Drop Lens Placement
Fig. 18 & 19: Drop Lens Securing

Aluminum Reflector Mounting

Accessory ordered separately - Model # H17-RAL, H17XL-RAL, H17XXL-RAL.

  1. Align the Reflector Screw Holes with the Heat Sink as shown in Fig. 20 & 21.
  2. Install Reflector onto the Heat Sink as shown in Fig. 22.
  3. Secure the Reflector to the Heat Sink with (4) Screws (provided) as shown in Fig. 23.
Fig. 20 & 21: Reflector Alignment
Fig. 22 & 23: Reflector Installation

Wire Guard Mounting

Accessory ordered separately - Model # H17-WG, H17B-WG, H17XL-WG, H17XLB-WG, H17XXL-WG, H17XXLB-WG.

  1. Align the Wire Guard Screw Holes with the Heat Sink as shown in Fig. 24 & 25.
  2. Install the Wire Guard onto the Heat Sink.
  3. Secure the Wire Guard to the Heat Sink with (4) Screws (provided) as shown in Fig. 26.
Fig. 24 & 25: Wire Guard Alignment
Fig. 26: Wire Guard Installation

Wire Guard Mounting (Continued)

Accessory ordered separately - Model # H17-DWG, H17XL-DWG.

  1. Align the Wire Guard with Heat Sink and secure with (4) Screws (provided) as shown in Fig. 27.
Fig. 27: Wire Guard Installation

Motion Sensor Installation

Accessory ordered separately - Model # MVS50, PIR40, MVS50/LCB, PIR40/LCB. Optional remote MSR1 sold separately for custom settings.

  1. Ensure power is off to the fixture to avoid risk of shock.
  2. Be sure to remove Sensor pin protector from the sensor before installing.
  3. Remove 1/2" Knockout with a screwdriver and install the Sensor Kit onto fixture (Fig. 11). Caution: Do not over-tighten Sensor.
Fig. 11: Sensor Installation

Drop Lens Mounting (Continued)

Accessory ordered separately - Model # H17-DDL, H17XL-DDL.

  1. Align the Drop Lens with Heat Sink and secure with (4) Screws (provided are 4 short screws and 4 long screws) as shown in Fig. 28.
Fig. 28: Drop Lens Installation
Fig. 29: Combined Wire Guard and Drop Lens Installation

Battery Backup

For Battery Backup accessory, see EMHB30, EMHB30/LCB, EMHB30/B, EMHB60, EMHB60/LCB, EMHB60/B.

Wiring

RISK OF FIRE. Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz. Units ordered with /480V suffix are 480V ONLY, 50 or 60Hz. For 0-10V dimming follow wiring directions as shown in Fig. 30.

Fig. 30: Wiring Diagram

Cleaning & Maintenance

CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.

  1. Do not open fixture to clean the LED. Do not touch the LED.
  2. Do not touch reflector, lens or trim cone.
  3. Do not clean any fixture surface with wood-base cleaning material such as paper towels or tissues.

Troubleshooting

  1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
  2. Is the fixture grounded properly?

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Models: H17, H17S, H17XL, H17XXL, H17XXL-480, H17XXL-480 Field Adjustable High Bay, H17XXL-480, Field Adjustable High Bay, Adjustable High Bay, High Bay

File Info : application/pdf, 6 Pages, 3.78MB

PDF preview unavailable. Download the PDF instead.

H17-Instructions 0

References

Adobe PDF Library 17.0 Adobe InDesign 20.3 (Windows)

Related Documents

Preview RAB Lighting H17 & H17XL LED High Bay Installation Instructions
Comprehensive installation guide for RAB Lighting's H17 and H17XL LED High Bay fixtures, covering hook mounting, surface mounting, pendant mounting, field-adjustable CCT/Wattage, wiring, and motion sensor installation.
Preview RAB Lighting H17 & H17XL Surface Mount Kit Installation Instructions
Comprehensive installation, cleaning, and maintenance guide for RAB Lighting's H17 and H17XL Surface Mount Kits. Includes essential safety warnings, step-by-step mounting instructions, and care recommendations.
Preview RAB Field-Adjustable SR™ LED Fixture Installation Instructions
Comprehensive installation guide for RAB Lighting's Field-Adjustable SR™ series LED fixtures. Covers surface mounting, V-hook/chain mounting, continuous run configurations, field adjustments for power and CCT, 0-10V dimming, PIR/MVS sensor integration, and battery backup options.
Preview RBAY15 Series LED Luminaire Installation and Field Adjustment Guide
Comprehensive installation, field adjustment, and maintenance guide for RAB Lighting's RBAY15S, RBAY15M, and RBAY15L LED luminaires. Includes mounting, wiring, sensor integration, battery backup, and troubleshooting instructions.
Preview RAB Lighting H17 & H17XL LED Fixture Installation Guide
Comprehensive installation instructions for RAB Lighting H17 and H17XL LED fixtures, covering hook, ceiling, and pendant mounting, wiring, CCT/wattage adjustment, and maintenance.
Preview RAB Field-Adjustable BOA Installation Instructions
Comprehensive installation guide for RAB's Field-Adjustable BOA LED lighting fixtures, covering wall, ceiling, surface, recessed, and pendant mounting methods, as well as field adjustments and battery backup operation.
Preview RBAY17™ Field-Adjustable LED High Bay Installation Guide | RAB Lighting
Detailed installation instructions for RAB Lighting's RBAY17™ series of field-adjustable LED high bay fixtures. Covers V-hook, chain, pendant, and surface mounting, field adjustments, sensor installation, wiring (0-10V, battery backup), cleaning, maintenance, and troubleshooting.
Preview RAB Lighting BULLET® Field-Adjustable LED Floodlight Installation Guide
Comprehensive installation, wiring, and adjustment guide for RAB Lighting's BULLET® Field-Adjustable LED floodlights, including sensor operation, mounting, and troubleshooting.