User Manual for RAB models including: H17, H17XL, H17XL Field Adjustable Round LED High Bay, H17XL, Field Adjustable Round LED High Bay, Adjustable Round LED High Bay, Round LED High Bay, LED High Bay
13 août 2022 — RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for ...
1 day ago — READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical ...
6 days ago — MOTION SENSOR INSTALLATION. (PURCHASED SEPARATELY). 1. Unscrew the Nuts on 1/2 ... Refer to wiring directions. 2. Is the fixture grounded properly? P ...
File Info : application/pdf, 3 Pages, 1.22MB
DocumentDocumentINSTRUCTIONS H17 & H17XL INSTALLATION RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com H17 H17XL IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. HOOK MOUNTING 1. Screw the Hook into the Fixture, tighten and fix it (Fig. 1). 2. Hang the Fixture on the Ceiling Hook or chain (Fig. 2). 3. After installation, connect the wire of the fixture to the mains. Use appropriate UL approved wire connectors as required by code to complete wiring. Fig: 1 Hook CEILING MOUNTING WITH ACCESSORY KIT 1. Mark with a pen or sharp tool on the mounting surface and drill. 2. Fix Screws into the holes with a hammer. 3. Align the Bracket Holes with Screw Holes (Fig. 3), push the Fixture to one side, and tighten Screws. 4. After installation, connect the wire of the fixture to the mains. Use appropriate UL approved wire connectors as required by code to complete wiring. By adjusting the bracket screws, users can adjust 50° to the left or right vertically (Fig. 4). Fixture Fig: 3 Screws (2) Screw Holes Fig: 2 Ceiling Hook Bracket Holes Fig: 4 100° INSTRUCTIONS H17 & H17XL INSTALLATION RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com PENDANT MOUNTING WITH ACCESSORY KIT 1. Unscrew the Nuts on 1/2" NTP (Fig. 5). 2. Insert 1/2" NTP stem into the Bracket Hole and re-screw the Nuts (Fig. 6). 3. After installation, connect the wire of the fixture to the mains. Use appropriate UL approved wire connectors as required by code to complete wiring. By adjusting the bracket screws, users can adjust 50° to the left or right vertically (Fig. 4). Fig. 5 1/2" NTP Nuts Fig. 6 FIELD-ADJUSTABLE CCT & WATTAGE 120 277V ONLY 1. The fixture has 3 selectable CCTs and 3 wattages. To access, remove the waterproof gasket, adjust the CCT and Power switches as needed (Fig. 9). Factory settings: H17: 150W and 4000K H17XL: 240W and 4000K Fig. 9 CCT Switch WIRING RISK OF FIRE. Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz. Units ordered with /480V suffix are 480V, 50 or 60Hz. Drop down supply wires must be at least 9" long to allow fixture removal. For 0-10V dimming follow wiring directions as shown in Fig. 7. For non-dimming (on/off ), Electronic Low Voltage (ELV) and TRIAC dimming follow the wiring directions as shown in Fig.8. Power Switch MOTION SENSOR INSTALLATION PURCHASED SEPARATELY 1. Unscrew the 1/2" Knockout out with a screwdriver and screw the Sensor Kit on (Fig. 10). Fig. 7 LINE COMMON ( + ) DIM V ( - ) DIM V BLACK WHITE PURPLE PINK LIGHT FIXTURE Fig. 10 GROUND GROUND 1/2" Sensor Knockout Kit Fig. 8 INSTRUCTIONS H17 & H17XL INSTALLATION RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com CLEANING & MAINTENANCE CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized. 1. Do not open fixture to clean the LED. Do not touch the LED. 2. Do not touch reflector, lens or trim cone. 3. Do not clean any fixture surface with wood-base cleaning material such as paper towels or tissues. TROUBLESHOOTING 1. Check that the line voltage at the fixture is correct. Refer to wiring directions. 2. Is the fixture grounded properly? Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. © 2022 RAB LIGHTING Inc. H17_H17XL-IN 0622 P-100099 Easy Answers rablighting.com Visit our website for product info Tech Help Line Call our experts: 888 722-1000 e-mail Answered promptly - sales@rablighting.com RAB WARRANTY: RAB's warranty is subject to all terms and conditions found at rablighting.com/warranty. Free Lighting Layouts Answered online or by request