- Circuit breaker function according to EN 60947-2
- Energy limitation class 3
- Simple replacement or expansion of installations thanks to modular design of the circuit breaker
- Simple mounting by clipping onto a DIN mounting rail in Ex e enclosures
- Thermally and magnetically adjusted tripping mechanism
- Ergonomic operating lever ensures safe connection and disconnection
- Protection against re-energization during maintenance using padlocks (Accessories)
The R. STAHL 8530 series circuit breakers offer excellent current limitation in case of short circuits and high breaking capacity of 10, 15, or 25 kA. This results in reduced stress on electrical lines and high selectivity with respect to upstream fuses. The modules are designed with a modular structure, available in 1 to 4 pole versions and for nominal currents from 0.5–63 A. The maximum mounting capacity is 4.5 division units.
Technical Data
Explosion Protection
Applications (zones) | 1, 2 |
Applications (zones) Note | Can be used in zones 21/22 with Ex tb/tc enclosure protection |
IECEX gas certification | IECEX FMG 19.0029U |
IECEx Gas Explosion Protection | Ex db eb IIC Gb |
ATEX gas certification | FM19ATEX0191U |
ATEX Gas Explosion Protection | II 2 G Ex db eb IIC Gb |
Certifications | ATEX (FM), Brazil (ULB), China (CQST), IECEX (FM) |
Certificate of Conformity | Certificate of Conformity (ATEX) |
Electrical Data
Rated operating voltage AC | 230/400 V |
Rated operating current | 50 A |
Frequency | 50/60 Hz |
Rated switching capacity | 10 kA |
Electrical service life | 2 x 104 |
Mechanical service life | 2 x 104 |
1st auxiliary function | Auxiliary contact 1 changeover + Error signal contact 1 changeover |
Voltage 1st auxiliary function AC | 230 V |
Max. current 1st auxiliary function | 2 A |
2nd auxiliary function | None |
Max. voltage 2nd aux. function DC | - |
Tripping characteristic | C |
Number of poles | 3-pole |
Environmental Conditions
Ambient temperature | -40 °C ... 70 °C |
Ambient temperature | -40 °F ... 70 °C |
Ambient temperature | -40 °C ... +158 °F |
Ambient temperature | -40°F ... +158°F |
Ambient temperature Note | Divergent ambient temperatures based on valid certificates upon request |
Mechanical Data
Degree of protection (IP) (IEC 60529) | IP2X |
Enclosure material | Thermoplastic |
Minimum connection cross-section | 1.5 mm² |
Maximum connection cross-section | 25 mm² |
Minimum AWG connection cross-section | 16 AWG |
Maximum AWG connection cross-section | 4 AWG |
Minimum connection cross-section 2 | 1.5 mm² |
Maximum connection cross-section 2 | 10 mm² |
Minimum AWG connection cross-section 2 | 16 AWG |
Maximum AWG connection cross-section 2 | 8 AWG |
Minimum HIKO connection cross-section | 0.5 mm² |
Maximum HIKO connection cross-section | 4 mm² |
Minimum HIKO connection cross-section AWG | 18 (unece.unit.AWG) |
Maximum HIKO connection cross-section AWG | 14 (unece.unit.AWG) |
Minimum torque | 2 N·m |
Maximum torque | 3 N·m |
Connection cross-section Note | 2 conductor connections (upper and lower chamber simultaneously): upper and lower chamber max. 16 / 10 mm² (only one cross-section difference can be connected in the upper and lower chamber). Permitted connection cross-section combinations are listed in the user manual. |
Dimensions
Width | 110 mm |
Mounting width in inches | 4.33 in |
Length | 165 mm |
Length inches | 6.5 in |
Installation depth | 138.3 mm |
Installation depth inches | 5.44 in |
Weight | 1.8 kg |
Weight | 3.969 lb |
Mounting / Installation
Torque | 2-3 N·m |
Torque lbf in | 17.7 ... 26.6 lbf-in |
Torque auxiliary contact | 0.4-0.6 Nm |
Torque auxiliary contact lbf in | 3.5 ... 5.3 lbf in |
Technical Diagrams
Tripping Characteristic Curve C: A graph shows the tripping time in seconds and minutes against the multiple of the rated current (I/In). The curve indicates the time delay for different overcurrent levels.
Measurement Diagram: A diagram illustrates the dimensions of the circuit breaker, including width, length, and depth, with measurements provided in both millimeters and inches. It also shows the mounting rail compatibility (8530/1; 4 division units).
Accessories
Cylinder Lock
Description: For locking (Ø 3 mm bracket)
Article No.: 107115
Quadruple Immobilization Device
Description: Locking and labeling pliers for individual component locking using up to 4 cylinder locks.
Article No.: 227232
Fixing Kit
Description: A set of fixings for mounting the component on the mounting plate without a top-hat rail.
Article No.: 276618