Embedded RFID Access Control
Introduction
The device is a single door standalone access control with Wiegand input & output. Card read (125KHz) and PIN (4-6 digits) access. It uses Atmel MCU assuring stable performance. The operation is very user-friendly, and low-power circuit makes it long service life.
Optional Version: The device with Bluetooth-enabled. People can install the Bluetooth APP to easily access the door with their smartphone. (APP operation can refer to APP manual)
Features
- Waterproof, conform to IP66
- Vandal resistant metal enclosure
- One relay (990 common users, 990 common + 10 visitor)
- Can add any 4-6 digits PIN, Infrared Remote Control
- Card Type: 125KHz EM Card/13.56MHz Mifare Card (optional)
- Wiegand 26 bits output, Wiegand 26/34bits input automatic identification
- Tri-color LED status display
- Pulse mode, Toggle mode
- Low temperature resistance (-40°C)
Specifications
Parameter | Value |
User Capacity | 1000 |
Common User | 990 |
Visitor User | 10 |
Operating Voltage | 12-18V DC |
Working Current | <=150mA |
Idle Current | <=60mA |
Proximity Card Reader | EM or Mifare |
Read Range | 2-5cm |
PIN Length | 4-6 digits |
Wiring Connections | Relay Output, Exit Button, Wiegand Input/Output, Wiegand Output |
Relay | Adjustable Output Time 0-99 Seconds (5-seconds default) |
Lock Output Load | 2 Amp Maximum |
Wiegand Interface | Wiegand 26 bits output, Wiegand 26/34bits input automatic identification |
Environment | Outdoor (Meets IP66) |
Operating Temperature | -40°C ~ 60°C (-40°F ~ 140°F) |
Operating Humidity | 0%RH~98%RH |
Physical | Stainless Steel Plate |
Surface Finish | Silver & Black |
Dimensions | 115x40x25mm (Rectangle), 86x86x25mm (Square) |
Unit Weight | 230g |
Shipping Weight | 270g |
Carton Inventory
- Diagram of a rectangular unit.
- Diagram of a square unit.
- Diagram of an infrared remote control.
- Diagram of a master card.
- Diagram of screw cover stickers.
- Diagram of self-tapping screws.
- Diagram of wall anchors.
- Diagram of Diode 1N4004 (for relay circuit protection).
Installation
- Drill two holes (A,C) on the wall for the screws and one hole for the device.
- Knock the supplied rubber bungs into the screw holes (A,C).
- Thread the cable through hole (B).
- Attach the unit to the hole (B).
- Fix the unit firmly on the wall with two flat head screws.
- Cover the screws with Screw Cover Stickers.
Basic Configure
Enter and Exit Program Mode
Programming Step | Keystroke Combination |
Enter Program Mode | * (Master Code) # (Factory default is 123456) |
Exit Program Mode | * |
Set Master Code
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code) # |
2. Update Master Code | 0 (New Master Code) # (Repeat New Master Code) # (Master code is any 6 digits) |
3. Exit Program Mode | * |
Connection Diagram
Common Power Supply
Diagram showing connections for Power Supply (12-18V DC), GND, NO, NC, COM, Red, Black, Brown, Grey, Yellow, Green, White wires. Labels include "Magnetic Lock", "Fail-safe Lock", "Exit Button".
Wiring
Colour | Function | Notes |
Red | Power + | 12~18V DC Votes DC Regulated Power Input |
Black | GND | Ground |
Blue | NO | Normally Open |
Brown | COM | Common Connection for Relay Output |
Grey | NC | Normally Close |
Yellow | OPEN | Request to Exit (REX) |
Green | D0 | Wiegand Input/Output Data 0 |
White | D1 | Wiegand Input/Output Data 1 |
Sound and Light Indication
Operation Status | LED | Buzzer |
Stand by | — | — |
Enter into programming mode | Red light | One beep |
In the programming mode | Red light | One beep |
Operation error | Red light | Three beeps |
Exit from the Programming mode | Green light | One beep |
Open lock: | Green light | One beep |
Alarm | Red light shines quickly | Beeps |
Controller Mode
(The device Operates as a Controller)
It supports Wiegand 26 bits input (Automatic Identification), so an external Wiegand device (26/34 bits output) can be connected to the device. Either an EM card reader (125 KHz) or a Mifare card reader (13.56MHz) can be connected to the device.
Cards are required to be added at the external reader, except where an external Wiegand Card Reader is used, in this case cards can be added at either a reader or controller.
Wiegand Mode
Pass-through Mode
(The device Operates as a Wiegand Reader)
In this mode the device supports a Wiegand 26 bits output. Wiegand data lines can be connected to any controller which supports a Wiegand 26 bits input, and then the device will operate as a slave reader.
Diagram showing connections for Wiegand device, Special Power Supply, Red, Black, Brown, Grey, Yellow, Green, White wires. Labels include D0, D1, GND, V+, COM, NO, NC, OPEN.
Others
Users Operation & Reset to Factory Default
- Open the door: Read valid card user or input valid PIN user.
- Active Alarm: Enter Master code or Card or valid card / PIN user.
- To reset to factory default & Add Master Card: Power off, press the Exit button, hold it and power on, there will be two beeps, then release the exit button, the LED light turns into yellow, then read any 125KHz EM card / 13.56MHz Mifare card, the LED will turn into red, means reset to factory default successfully. Of the card reading, it is the Master Card.
Master Card Usage
Using Master Card to add and delete users
Add Card / PIN Users | 1. Input (Master Card) 2. Input (Card) or (PIN #) Repeat step 2 for additional users 3. Input (Master Card) again |
Delete Card / PIN Users | 1. Input (Master Card Twice within 5s) 2. Input (Card) or (PIN #) Repeat step 2 for additional users 3. Input (Master Card) again |
Notes
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
Simplified Instruction
Function Description | Operation |
Enter the Programming Mode | * - Master Code - # (Input you can do the programming (123456 is the factory default master code) |
Change the Master Code | 0 - New Code - # - Repeat the New Code - # (code: 6 digits) |
Add User | 1 - Read Card - # (can card slots continuously) |
Add PIN User | 1 - PIN - # (The PIN is any 4-6 digits except 8888 which is reserved.) (Input PIN on the Infrared Remote Control) |
Delete User | 2 - Read Card - # OR 2 - User ID - # OR 2 - By Card number # OR 2 - ALL Users |
Exit from the Programming Mode | * |
How to release the door | Card User: Read Card PIN User: Input PIN # |
Add Common Users
PIN Length: 4-6 digits except 8888.
Add Card User
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code) # |
2. Using Auto ID (Allows the device to assign Card to next available User ID number) |
1 (Read Card) # (Input 8/10/17 Digits Card Number) # (The cards can be added continuously.) |
OR | |
2. Select Specific ID (Allows Master to define a specific User ID to associate the Card to) |
1 (User ID) # (Read Card) # (Input 8/10/17 Digits Card Number) # (The cards can be added continuously.) |
OR | |
2. Add Card; Block Enrollment (Allows Master to add up to 988 cards to the Reader in a single step) Takes 2 minutes to program. |
1 (User ID) # (Card Quantity) # (The First Read Card 8/10/17 Digits Number) # (Cards' quantity must be consecutive; Card quantity is the number of cards to be enrolled) |
Add PIN User
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code) # |
2. Using Auto ID (Allows the device to assign PIN to next available User ID number) |
1 (PIN) # (The PINs can be added continuously.) |
OR | |
2. Select Specific ID (Allows Master to define a specific User ID to associate the PIN to) |
1 (User ID) # (PIN) # |
Add Visitor Users
User ID is 990~999; PIN length: 4-6 digits except 8888. There are 10 groups Visitor/PIN card, the users can be specified up to 10 times of usage, after a certain number of times, i.e. 5 times, the PIN become invalid automatically.
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code) # |
2. Add Card | 1 (Read Card) # OR 1 (PIN) # |
3. Exit | * |
Change PIN Users
PIN Length: 4-6 digits except 8888.
Note: Below is done outside programming mode, users can only do this themselves.
Change PIN | Keystroke Combination |
Change PIN of Card + PIN access mode | * (User ID) # (New PIN) # (Old PIN) # (Repeat New PIN) # |
Delete Users
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code) # |
2. Delete Card | 2 - Read Card - # OR 2 (Card/PIN Input) # |
OR | |
2. Delete User - By Card number | 2 (User ID) # |
OR | |
2. Delete User - By ID number | 2 (Input 8/10/17 Digits Card Number) |
OR | |
2. Delete ALL Users | 2 (Master Code) # |
3. Exit | * |
Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation.
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code) # |
2. Pulse Mode | 3 (1~99) # (factory default) The relay time is 1-99 seconds. (Default is 5 seconds) |
OR | |
2. Toggle Mode | 3 0 # Sets the relay to ON/OFF Toggle mode |
3. Exit | * |
Set Access Mode
For Multi user access mode, the interval time of reading can not exceed 5 seconds, or else, the device will exit to standby by automatically.
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code) # |
2.0 Access | 4 0 # |
OR | |
2.1 PIN Access | 4 1 # |
OR | |
2.2 Card Access | 4 2 # |
OR | |
2.3 Card or PIN Access | 4 3 (factory default) |
OR | |
2.4 Multi User Access | 4 3 (2~9) # (Only after 2~9 valid users, the door can be opened) |
3. Exit | * |
Set Audible and Visual Response
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code) # |
2. Disable Sound | 7 0 # (factory default) |
OR | |
2. Enable Sound | 7 1 # (factory default) |
OR | |
2. Leave Always OFF | 7 2 # |
OR | |
2. LED Always ON | 7 3 # (factory default) |
3. Exit | * |