Secukey VCONTROL 4-R Video Intercom with Access Control
Product Overview
The Secukey VCONTROL 4-R is a video intercom system that integrates access control functionality. It is designed for secure and convenient communication and entry management.
Technical Specifications
General Specifications
Parameter | Specification |
---|---|
Power Supply | DC 12-24V |
Working Temperature | -40°C to +70°C |
Working Humidity | 10% to 90% RH |
Dimensions | 140mm x 150mm x 45mm |
Waterproof Rating | IP65 |
User Capacity | 1,000 users (990 common + 10 admin) |
Relay Output | 1 |
RFID Card Capacity | 1,000 users |
Communication | Full duplex voice intercom |
Video Calling | WiFi-based |
Case Material | Metal, anti-vandal |
Wiring Diagram
The system utilizes a standard wiring configuration for power, door lock, exit button, and optional doorbell. A detailed diagram illustrates the connections between the VCONTROL 4-R unit, power supply, electric lock, and exit button.
Key Connections:
- Power Input: Connect to DC 12-24V power supply.
- Door Lock Output: Connect to the electric lock mechanism.
- Exit Button Input: Connect to an external push-button for exiting.
- Door Sensor Input: For monitoring door status.
- Wiegand Input/Output: For integration with external access control systems.
Installation Instructions
Follow these steps for proper installation:
- Mounting: Select a suitable location for the VCONTROL 4-R unit, ensuring it is accessible and protected from extreme weather if necessary. Mount the unit securely using the provided hardware.
- Wiring: Connect the power supply, electric lock, exit button, and any other required peripherals according to the wiring diagram. Ensure all connections are secure and insulated.
- Configuration: Power on the unit and follow the on-screen prompts or manual configuration steps to set up network connectivity (if applicable), user access, and lock release times.
- Testing: Test the intercom functionality, door release, and access control features to ensure they are working correctly.
Access Control Features
The VCONTROL 4-R supports multiple access methods:
- RFID Cards: Users can gain access by presenting a valid RFID card.
- PIN Codes: Access can be granted using a pre-programmed PIN code.
- Remote Access: Depending on the model and configuration, remote access via a mobile app or other network interfaces may be available.
Troubleshooting
Issue: No power to the unit. Solution: Check the power supply connection and ensure the voltage is within the specified range (DC 12-24V).
Issue: Door lock not releasing. Solution: Verify the wiring to the electric lock and check the power supply to the lock. Ensure the unit is configured to activate the relay.
Issue: RFID card not recognized. Solution: Ensure the card is compatible with the system's frequency (e.g., 125KHz or 13.56MHz) and has been correctly programmed into the system.
Maintenance
Regularly clean the unit's exterior with a soft, damp cloth. Avoid using abrasive cleaners. Periodically check wiring connections for any signs of damage or corrosion.
Contact Information
For support or inquiries, please refer to the manufacturer's official website or contact their authorized distributors.