Secukey Electric Bolt Lock User Manual
This manual provides instructions for the installation and operation of the Secukey electric bolt lock.
1. Specifications
The lock operates on 12VDC or 24VDC and features a self-locking bolt. It includes door and bolt status sensors for monitoring and has a time delay function.
2. Installation and Instructions
Please read the manual before installation and ensure all accessories are present.
The lock consists of a magnetic plate and the lock itself. The distance between the magnetic plate and the bolt should be less than 3 mm.
There are 9 wires: red, black, blue, white, yellow, green, grey, orange, and violet.
Wiring:
- 12VDC Wiring: Refer to Figure 2-B. Red wire to DC12V+, Black wire to DC12V-.
- 24VDC Wiring: Refer to Figure 2-A. Red wire to DC24V+, Purple wire to DC24V-.
Sensor Wiring:
- Bolt Sensor: Blue wire (NO), White wire (COM), Yellow wire (NC). (Figure 3-A)
- Door Sensor: Green wire (NO), Grey wire (COM), Orange wire (NC). (Figure 3-B)
Time Delay Adjustment: The time delay is located in the middle of the lock (Figure 4) and can be set to 0, 3, or 6 seconds.
Installation Diagram: Refer to Figure 5 for installation details.
3. Parameters
- Lock Dimensions: 200L * 28W * 39H mm
- Bolt: 12.5 mm diameter, 15±1 mm stainless steel bolt length.
- Operating Voltage: DC12V±10%
- Current Draw: 1100mA (startup), 140mA (standby)
- Delay: 0, 3, 6 seconds
4. Accessories
- Iron Plate: 2 pcs
- Magnetic Plate: 90L * 24W * 3H mm (1 pc)
- Screws: M5 * 15mm (5 pcs); M4*11mm (5 pcs)