XBA-KZT6 Bill Acceptor Option Switch Settings
Supported Bill Types: KZT 200, 500, 1000, 2000, 5000, 10000 (6 bills)
XBA Option Switch Settings (Pulse/MDB/ICT104U/ICT104V)
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Reject KZT 200 | ON | |||||||
Accept KZT 200 | OFF | |||||||
Reject KZT 500 & 1000 | ON | |||||||
Accept KZT 500 & 1000 | OFF | |||||||
Reject KZT 2000 | ON | |||||||
Accept KZT 2000 | OFF | |||||||
Reject KZT 5000 | ON | |||||||
Accept KZT 5000 | OFF | |||||||
Reject KZT 10000 | ON | |||||||
Accept KZT 10000 | OFF | |||||||
Disable Bill Reject 4 Times BA Stop By 30 Sec | ON | |||||||
Enable Bill Reject 4 Times BA Stop By 30 Sec | OFF | |||||||
Stack Banknote when Power-up | ON | |||||||
Reject Banknote when Power-up | ON | |||||||
Reserved | OFF | |||||||
Reserved | OFF |
This dip switch is located at the side of XBA.
Diagram: A side view of the XBA unit is shown. A circular callout labeled (2) highlights the DIP Switch located on the side of the unit.
Currency Assign Data
Bill value | Interface | ICT104U | ICT104V | Pulse | MDB |
---|---|---|---|---|---|
BV1 KZT 200 | KZT 200 | KZT 200 | KZT 200 | KZT 200 | KZT 200 |
BV2 KZT 500 | KZT 500 | KZT 500 | KZT 500 | KZT 500 | KZT 500 |
BV3 KZT 1000 | KZT 1000 | KZT 1000 | KZT 1000 | KZT 1000 | KZT 1000 |
BV4 KZT 2000 | KZT 2000 | KZT 2000 | KZT 2000 | KZT 2000 | KZT 2000 |
BV5 KZT 5000 | KZT 5000 | KZT 5000 | KZT 5000 | KZT 5000 | KZT 5000 |
BV6 KZT 10000 | KZT 10000 | KZT 10000 | KZT 10000 | KZT 10000 | KZT 10000 |
XBA-KZT6 (Pulse/MDB/ICT104U/ICT104V) Option Switch Settings
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Inhibit Active HIGH | ON | |||||||
Inhibit Active LOW | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Pulse Mode | MDB Mode | ICT104V Mode | ||||||
Credit-Pulse Normal HIGH | Scaling Factor (SF) = 0.01 Decimal Point Position (DPP) = 0 | Connect with coin changer ON | Connect with ICT JPSTD converter board ON | |||||
Credit-Pulse Normal LOW | Scaling Factor (SF) = 1 Decimal Point Position (DPP) = 0 | Connect with coin changer OFF | Connect with ICT JPSTD converter board OFF | |||||
Pulse Mode | Other Mode | ON | ||||||
Pulse Mode | Other Mode | OFF | ||||||
1 pulse / KZT 100 | MDB Mode | OFF | OFF | |||||
2 pulses / KZT 100 | Reserved | OFF | ON | |||||
5 pulses / KZT 100 | ICT104U Mode | ON | OFF | |||||
20 pulses / KZT 100 | ICT104V Mode | ON | ON |
This dip switch is located on the CPU board, remove the CPU board cover first.
Diagram: An illustration shows the process: first, the CPU board cover is removed. Then, a close-up view of the DIP Switch, labeled (1), is presented.
Manufacturer Settings
* After setting dip switch of the credit pulses, you should reset the bill acceptor again.
Note:
- Please reset the bill acceptor after set the dip switch.
- Dip switches 1 to 5 are only used for pulse protocol.
- Calibration card is needed.